Design of a volumetric cylindrical coil-tuned at 298 MHz for 7 T imaging [0.03%]
一种用于7T成像的298MHz柱形体积线圈的设计
Shadeeb Hossain,Victor Taracila,Fraser J L Robb et al.
Shadeeb Hossain et al.
The concept of a 2D cylindrical High Pass Ladder (2D c-HPL) is used in the development of this ultra high radio frequency (UHRF) volumetric head coil for 7T tuned at the Larmor frequency of 298 MHz. The architecture of the 2D c-HPL helps to...
Optimization of the linear quantification range of an online trypsin digestion coupled liquid chromatography-tandem mass spectrometry (LC-MS/MS) platform [0.03%]
在线胰蛋白酶消化液质联用平台线性定量范围的优化
Zsuzsanna Kuklenyik,Jeffrey I Jones,Christopher A Toth et al.
Zsuzsanna Kuklenyik et al.
Tandem mass spectrometry (MS/MS)-based proteomic workflows with a bottom-up approach require enzymatic digestion of proteins to peptide analytes, usually by trypsin. Online coupling of trypsin digestion of proteins, using an immobilized enz...
Pneumatic piston hydrostatic bioreactor for cartilage tissue engineering [0.03%]
用于软骨组织工程的气动活塞式静水压生物反应器
J Hallas,A J Janvier,K F Hoettges et al.
J Hallas et al.
During exercise, mechanical loads from the body are transduced into interstitial fluid pressure changes which are sensed as dynamic hydrostatic forces by cells in cartilage. The effects of these loading forces in health and disease are of i...
Real-time, label-free characterization of oligosaccharide-binding proteins using carbohydrate microarrays and an ellipsometry-based biosensor [0.03%]
基于椭偏光学生物传感器的碳水化合物微阵列实时无标记寡糖结合蛋白分析
Yung-Shin Sun,X D Zhu
Yung-Shin Sun
Carbohydrates present on cell surfaces mediate cell behavior through interactions with other biomolecules. Due to their structural complexity, diversity, and heterogeneity, it is difficult to fully characterize a variety of carbohydrates an...
Yung-Shin Sun,James P Landry,X D Zhu
Yung-Shin Sun
Optical biosensors provide a platform for qualitatively and quantitatively analyzing various biomolecular interactions. In addition to advantages such as label-free and high-throughput detection, these devices are also capable of measuring ...
Pulsed Nano-Electrospray Ionization: Characterization of Temporal Response and Implementation with a Flared Inlet Capillary [0.03%]
脉冲式纳滴电喷雾离子化:时间响应表征及带扩口毛细管的实现方法
Jared M Bushey,Desmond A Kaplan,Ryan M Danell et al.
Jared M Bushey et al.
The temporal response of pulsed nano-electrospray ionization mass spectrometry (nano-ESI-MS) was studied and its influence on ion formation and detection was characterized. Rise and decay times for the mass resolved ion current were determi...