Depth-sensitive optical property characterization using multi-frequency laparoscopic spatial frequency domain imaging [0.03%]
基于多频拉曼空间频率域成像的深度敏感光学特性表征
Elias Kluiszo,Luigi Belcastro,Rasel Ahmmed et al.
Elias Kluiszo et al.
Accurate knowledge of tissue absorption (μ a ) and reduced scattering (μs '), parameters is required to plan and monitor laparoscopic chemophototherapy (CPT) in ovarian cancer, including light dosimetry and quantitative fluorescence mappi...
Real-time monitoring and quantitative analysis of PAG-mediated chemical cochleostomy using 1.06-µm swept-source optical coherence tomography [0.03%]
基于1.06微米扫频源光学 coherence 技术的PAG介导化学迷路入路的实时监测及量化分析
You-Nan Tsai,Chuan-Bor Chueh,Ting-Hao Tsai et al.
You-Nan Tsai et al.
Traditional cochleostomy relies on mechanical drilling, which carries inherent risks of acoustic and thermal trauma. In this study, we performed a quantitative analysis of phosphoric acid gel (PAG)-mediated chemical cochleostomy in ex vivo ...
Monte Carlo-based correction of geometric and instrumental biases in single-distance time-domain near-infrared spectroscopy on skeletal muscle [0.03%]
基于蒙特卡洛的几何和仪器偏差校正单距离时域近红外光谱检测骨骼肌中的参数
Marco Nabacino,Caterina Amendola,Letizia Contini et al.
Marco Nabacino et al.
Time-Domain Near-Infrared Spectroscopy (TD NIRS) data from skeletal muscle are commonly analyzed using homogeneous models for photon diffusion, introducing substantial bias when the skeletal muscle is overlain by a thick superficial adipose...
Proto-clinical optoretinography dependence on temporal and spatial resolution [0.03%]
基于时间和空间分辨率的准临床光视网膜成像技术研究
Arman Athwal,Ringo Ng,Ayoub Faraji et al.
Arman Athwal et al.
Optoretinography (ORG) enables non-invasive measurement of stimulus-evoked photoreceptor deformation using phase-sensitive optical coherence tomography (OCT). In this study, we evaluated how lateral resolution, acquisition speed, and spatia...
Spectroscopic correlation tomography (SpCT) for visualization of spatial correlations in volumetric OCT scans [0.03%]
基于光相干断层扫描数据的空间相关性可视化 spectroscopic correlation tomography(spct)技术
Erin C OKane,Robert E Highland rd,Venkataramana Thiriveedi et al.
Erin C OKane et al.
Spectroscopic optical coherence tomography (SOCT) allows for the targeted analysis of cell nuclei due to their spectrally distinct scattering properties. SOCT has been explored for optical biopsy based on its ability to extract structural a...
First-order field autocorrelation function analysis-based dynamic OCT for tissue viability assessment [0.03%]
基于一阶场自相关函数分析的动态OCT组织活力评价方法
Wei Chen,Jinze Zhang,Lingxuan Meng et al.
Wei Chen et al.
This work introduces g1-dOCT, which derives a dynamic index Id from the first-order field autocorrelation function for long-term tissue viability assessment. The method encodes activity intensity directly as image brightness, offering intui...
Missed isochromatic cardiac pulsation in remote photoplethysmography: detection, impact, and removal [0.03%]
远程光电容积图摄影中遗漏的同色心脏脉搏:检测、影响及去除
Gurnoor Kaur,Vasudevan Lakshminarayanan,Simarjeet Singh Saini
Gurnoor Kaur
Remote photoplethysmography (rPPG) extracts the cardiac pulse from facial video by isolating chromatic variation due to wavelength-dependent hemoglobin absorption. We report that this signal model is incomplete. A second cardiac-frequency s...
Quantification and mitigation of system background fluorescence in fiber-optic-based imaging systems [0.03%]
光纤成像系统中量化和减轻系统背景荧光的方法
Eric Brace,Jeanie Malone,Adrian Tanskanen et al.
Eric Brace et al.
Autofluorescence imaging provides a snapshot of tissue biochemistry that can be used to identify dysplastic tissue. However, deployment in multimodal single-fiber imaging systems is limited by system background fluorescence. We propose to i...
Dual-scale and dual-channel oblique plane microscopy for multi-resolution imaging of large tissue specimens [0.03%]
用于大型组织样本多分辨率成像的双尺度和双通道斜面显微镜
Jisang Lee,Suil Jeon,Jihyun Chun et al.
Jisang Lee et al.
Oblique plane microscopy (OPM) is a single-objective implementation of light sheet fluorescence microscopy (LSFM) that enables volumetric imaging in an open-top configuration suitable for large tissue specimens. Such applications require bo...
Erratum: Defining the optimal imaging time point for fluorescence-lifetime-based tumor identification using the non-targeting near-infrared dye indocyanine green and post-processed high-dynamic-range images: errata [0.03%]
荧光寿命成像使用非靶向近红外染料亚甲蓝和高动态范围图像进行肿瘤识别的最优成像时间点的定义:勘误通知书
S Janssen,T Van den Dries,N Lina Kheiro et al.
S Janssen et al.
[This corrects the article on p. 1953 in vol. 17, PMID: 42110997.]. © 2026 Optica Publishing Group.
Published Erratum
Biomedical optics express. 2026 Jun 8;17(7):3498-3501. DOI:10.1364/BOE.603944 2026