Three-dimensional Finite Element Analysis of Quad Zygomatic, Transnasal and Pterygoid Implants for Rehabilitation of Patients with a Severely Atrophic Maxilla [0.03%]
用于重度萎缩上颌修复的四枚颧牙种植体、经鼻和翼状种植体的三维有限元分析
Onur Şahin,Onur Odabaşı,Xhini Rizaj et al.
Onur Şahin et al.
Purpose: The aim of this study is to compare the effects of different occlusal forces on quad zygoma, transnasal and pterygoid implants in patients with severely atrophic maxilla using finite element analysis. ...
Adhesive Wear Assessment of the Prosthetic Abutment and Detorque Values of Conical Connection Implants with Different Conicities [0.03%]
不同锥度种植体连接件的固位扭矩及其摩擦磨损评价
Luiz Rodrigo Côtes Lopes,Marcelo Sperandio,Carlos Nelson Elias et al.
Luiz Rodrigo Côtes Lopes et al.
Purpose: Morse taper connection presents better functional load distribution than other types of connections. The angle and finishing surfaces are used to prevent components from loosening under direct axial load. The ang...
Short/Long-term Clinical Evaluation of "Planned" Implant Overdentures: Retrospective Cohort Study [0.03%]
种植体 overdenture 的短期和长期临床疗效的回顾性队列研究
Shirai Mai,Suzuki Ginga,Shimizu Satoshi et al.
Shirai Mai et al.
Purpose: Implant overdenture rehabilitation has recently become a common treatment for patients. However, few papers present long-term observations (over 10 years) of IOD/IRPD. The purpose of this study was to investigate...
Clinical Evaluation of Short and Standard-Length Implants in Posterior Regions of the Partially Edentulous Maxilla and Mandible - A Prospective Comparative Study [0.03%]
短种植体与标准长度种植体在部分缺牙的上下颌后牙区的临床疗效比较研究
Frank Peter Strietzel,Henrik Dommisch
Frank Peter Strietzel
Purpose: To compare clinical outcomes of short (6 and 8 mm) and standard-length (11 and 13 mm) implants in posterior sites. It was hypothesized that both implant types exhibit no difference regarding implant survival rate...
Infraposition, Esthetics, Survival, and Complications of Implant- Supported Crowns in the Anterior Maxilla: A Retrospective Study with 11-21 Years Follow-up [0.03%]
前牙区种植美学区位、美学效果及长期存留影响因素回顾性研究(11-21年)
Niklas Landin,Canan Kaya,Evaggelia Papia et al.
Niklas Landin et al.
Background: Implant-supported single crowns (ISSCs) are a common treatment option for replacing missing teeth in the anterior maxilla. Extensive long-term studies are still needed to report on esthetic qualities, clinical...
Effect of Screw Access Hole Location on the Intaglio Fit and Fracture Resistance of Implant-Supported Monolithic Zirconia Crown [0.03%]
螺孔位置对全瓷锆石植入物支持单体的嵌合配合和断裂阻力的影响
Han-Sol Song,Kyung-Ho Ko,Yoon-Hyuk Huh et al.
Han-Sol Song et al.
Purpose: To evaluate the effect of screw access hole (SAH) presence and location on the marginal and intaglio fit and fracture resistance of zirconia crowns. ...
What We Have Learned in the Treatment of Seven Severely Atrophic Maxillary Full-Arch Immediate-Load Protocol Patient Cases Treated with a Digitally Planned and Produced Screw-Retained Subperiosteal Implant, a Case Series with Surgical and Initial Prosthetic Outcomes [0.03%]
数字化上颌窦下道种植体的临床研究:一期植入即刻负重的病例报告及初步疗效观察
Gary Orentlicher,Peter Rekawek,Ariana Etessami et al.
Gary Orentlicher et al.
The volume and morphology of alveolar bone drives the rehabilitation of edentulous patients. Rehabilitation of the atrophic ridge remains a challenge, both surgically and prosthetically. Commonly, bone grafting procedures, in combination wi...
Evaluation of the Effect of Electronic Cigarette Aerosol on Normal and Diabetic Human Fibroblast Interaction with Dental Implant Materials [0.03%]
电子烟气溶胶对正常和糖尿病人类成纤维细胞与牙科植入材料相互作用的影响评估
Maya El Choueiri,Fatima-Zahrae Laaboudi,Ze Zhang et al.
Maya El Choueiri et al.
Purpose: Electronic cigarette (e-cig) aerosol encounters all constituents in users' mouths, including soft and hard tissues and dental implants. Deposition of the e-cig aerosols on dental implants can lead to implant fail...
Scan Body Discrepancies in Bone- and Tissue-Level Implants: In Vitro Study [0.03%]
基于骨水平和软组织水平种植体的扫描体差异的离体研究
Ameer Biadsee,Reema Yusef,Guy Melamed et al.
Ameer Biadsee et al.
Purpose: This study assessed horizontal and vertical discrepancies in polyetheretherketone implant scan bodies on bone-level tapered and tissue-level implants at varying torque levels using scanning electron microscopy. ...