AR-CPR 2.0: Validation of the Accuracy and Precision of a Wearable Coaching System for Improving Chest Compression Performance [0.03%]
AR-CPR 2.0:评估可穿戴教练系统改善胸部按压性能的准确性和精确性
Keith Kleinman,James L Dean,Erika Yu et al.
Keith Kleinman et al.
Pediatric cardiopulmonary resuscitation (CPR) quality remains inconsistent, with low adherence to guideline-recommended compression rate and depth. Augmented reality cardiopulmonary resuscitation (AR-CPR) is an augmented reality feedback sy...
Verification and Validation of an Autotuning Proportional-Integral-Derivative Controller for Spatially Confined Magnetic Particle Hyperthermia [0.03%]
用于空间受限磁性颗粒热疗的自动调谐比例积分微分控制器的验证与确认
Shreeniket Pawar,Hayden Carlton,Yash Sharad Lad et al.
Shreeniket Pawar et al.
We have previously verified the capabilities of a prototype magnetic nanoparticle (MNP) heater (called HYPER) that can perform spatially confined heating; however, the design lacked temperature control capabilities. In this work, we designe...
An In Vitro Platform for Pharmacokinetic Quantification and Optimization of Cerebrospinal Fluid Filtration and Drug Circulation [0.03%]
一种用于药代动力学量化和优化脑脊液滤过和药物循环的体外平台
Lucas R Sass,Mohammadreza Khani,Michael C Giordano et al.
Lucas R Sass et al.
Modification of cerebrospinal fluid (CSF) transport dynamics is an expanding method for treating central nervous system injury and diseases. One application of this route is to modify the distribution of solutes in the CSF; however, few too...
The Sensation Meter: An Unprompted Method to Characterize Patient-Reported Bladder Sensation in Real-Time [0.03%]
膀胱感觉量表:一种表征患者报告的实时膀胱感觉的无提示方法
John E Speich,Anna S Nagle,Stefan G De Wachter et al.
John E Speich et al.
MBaFus: A Virtual Lab of Microbubble-Augmented Focused Ultrasound for Noninvasive Tumor Ablation Based on Two-Way Coupled Euler-Lagrange Modeling [0.03%]
基于欧拉-拉格朗日两向耦合模型的微泡增强聚焦超声非侵入性肿瘤消融虚拟实验室(MBaFus)
Jingsen Ma,Chao-Tsung Hsiao,Aswin Gnanaskandan et al.
Jingsen Ma et al.
Focused ultrasound (FUS), especially when augmented by microbubbles (MBs), shows the potential for noninvasive ablation of deep-seated tumors, but its clinical adoption is hindered due to its dependency on multiple controllable parameters o...
An MR-Safe Pneumatic Stepper Motor: Design, Control, and Characterization [0.03%]
一种MR安全气动步进电机:设计、控制和特性分析
Gang Li,Pavel Yarmolenko,Kevin Cleary et al.
Gang Li et al.
Magnetic resonance imaging (MRI) can provide high contrast soft tissue visualization without ionizing radiation, which makes it an attractive imaging modality for interventional procedures. However, the strong magnetic and radio frequency (...
Designs of Upper Limb Tremor Suppression Orthoses: Efficacy and Wearer's Comfort [0.03%]
上肢震颤抑制矫形器的设计:有效性与穿戴舒适度
MoYan ChiGan,Manlong Chen,Min Jing
MoYan ChiGan
Tremor is a rhythmic, involuntary oscillatory movement that severely affects some aspects of a patient's daily life. The use of wearable tremor-suppressing orthoses has become an effective, noninvasive treatment method for controlling tremo...
Controlled Ice Nucleation With a Sand-PDMS Film Device Enhances Cryopreservation of Mouse Preantral Ovarian Follicles [0.03%]
一种沙粒-PDMS薄膜控制冰核化装置增强小鼠卵巢未成熟卵泡的冷冻保存能力
Samantha Stewart,Alisa White,Wenquan Ou et al.
Samantha Stewart et al.
Ovarian follicle cryopreservation is a promising strategy for fertility preservation; however, cryopreservation protocols have room for improvement to maximize post-thaw follicle viability and quality. Current slow-freezing protocols use ei...
Design and Implementation of a Computer-Controlled Hybrid Oscillatory Ventilator [0.03%]
一种计算机控制的混合振荡通气机的设计与实现
Andrea F Cruz,Jacob Herrmann,Bakir Hajdarevic et al.
Andrea F Cruz et al.
During mechanical ventilation, lung function and gas exchange in structurally heterogeneous lungs may be improved when volume oscillations at the airway opening are applied at multiple frequencies simultaneously, a technique referred to as ...
Mechanical Viability and Functionality Assessment of a New Sutureless Endoluminal Microvascular Device: A Preliminary In Vivo Rabbit Study [0.03%]
一种新型无张力内血管器械的机械可行性和功能评估:兔在体实验研究
Jordi Descarrega,Joan Fontdevila,Erica Segura et al.
Jordi Descarrega et al.
Our group has developed a new nitinol endoluminal self-expandable device for microvascular anastomosis. It attaches to each vessel ending with opposite directed microspikes and reaches complete expansion at body temperature, using the nitin...