A first-in-human, prospective feasibility trial of a next-generation, shear-responsive, liquid embolic biomaterial, NeoCast [0.03%]
一种新型剪切响应型液态栓塞生物材料NeoCast的首个人体、前瞻性可行性试验
Lee-Anne Slater,Laetitita de Villiers,Adam S Arthur et al.
Lee-Anne Slater et al.
Background: NeoCastTM is a solvent-free, non-adhesive biomaterial engineered to achieve microvascular occlusion. EMBO-01 is the first-in-human trial of NeoCast for the pre-surgical embolization of hypervascular brain tumo...
Copper filtration reduces radiation dose while maintaining image quality in cerebral flat-detector CT [0.03%]
铜过滤片可降低辐射剂量而不影响脑平板CT图像质量
Niclas Schmitt,Tim Hilgenfeld,Dominik F Vollherbst et al.
Niclas Schmitt et al.
Background: Flat-detector computed tomography (FDCT) is increasingly used for peri-interventional cerebral imaging but is associated with a relatively high radiation exposure. Copper (Cu) filtration may reduce radiation d...
Thunderbolt System for acute ischemic stroke secondary to large vessel occlusion: primary results of the THUNDER study [0.03%]
用于急性大血管闭塞性脑梗死的雷霆取栓系统:THUNDER研究的主要结果
David Fiorella,Keith Woodward,Charles Matouk et al.
David Fiorella et al.
Introduction: THUNDER (Acute Ischemic Stroke Study With the Penumbra System Including Thunderbolt Aspiration Tubing) was the first study to evaluate the safety and effectiveness of a proprietary computer assisted vacuum t...
Ankyras simulation for flow diversion of intracranial aneurysms: a standardized workflow integrated clinical validation study [0.03%]
基于临床验证的动脉瘤血流导向治疗锚点区模拟标准化流程研究
Alan R Rheaume,Christine Denice,Seyed Morsal Mosallami Aghili et al.
Alan R Rheaume et al.
Background: Accurate flow diverter (FD) sizing is critical for successful intracranial aneurysm (IA) treatment. We evaluated the predictive performance of the Ankyras FD simulation platform within a standardized simulatio...
First multicenter experience with the SOFIA 88 super-large-bore aspiration catheter in mechanical thrombectomy [0.03%]
SOFIA 88大口径抽吸导管机械性血栓切除术的首次多中心经验
Sophia Hohenstatt,Răzvan Alexandru Radu,Anca Negrila et al.
Sophia Hohenstatt et al.
Background: Super-large-bore aspiration catheters are designed to improve clot engagement and aspiration efficiency during mechanical thrombectomy. However, multiple 0.088-inch platforms are now available, and device-spec...
In reply: the randomized evidence supports a class I, level A recommendation for adjunctive middle meningeal artery embolization [0.03%]
答:随机对照研究证据支持脑膜中动脉栓塞作为A级I类推荐的辅助治疗措施
Justin R Mascitelli,Clemens M Schirmer
Justin R Mascitelli
Fernanda Rodriguez-Erazú,Jildaz Caroff,Dan Adrian Popica et al.
Fernanda Rodriguez-Erazú et al.
Background: Concerns have arisen regarding flow diverter braid deformation (FDBD), particularly with last-generation platinum drawn-filled tube (DFT) wire devices. Braid deformation is likely multifactorial, influenced by...
Intra-procedural SSEP latency stratifies functional outcome after successful endovascular thrombectomy [0.03%]
成功的血管内取栓术后的皮质骨髓通道SSEP传导时间可以预示功能结局
Su Ji Lee,Joonwon Lee,Sung-Tae Kim et al.
Su Ji Lee et al.
Background: Successful angiographic reperfusion during endovascular thrombectomy (EVT) does not reliably predict 90-day functional recovery. Whether intra-procedural somatosensory evoked potential (SSEP) latency dynamics ...
First-pass aspiration versus stent retriever thrombectomy: machine learning study of treatment effect heterogeneity [0.03%]
首次抽吸与支架取栓的异质性研究:机器学习分析
Huanwen Chen,Julio Isidor,Clemens Schirmer et al.
Huanwen Chen et al.
Background: Randomized trials have shown equivocal outcomes between a direct aspiration as first-pass technique (ADAPT) and stent retriever (SR) stroke thrombectomy, yet whether specific patient subgroups benefit differen...