Characterization of natural and artificial radionuclide concentrations in soil and ecological dose screening using RESRAD-BIOTA: a baseline study of El Kala National Park, Algeria [0.03%]
利用RESRAD-BIOTA表征和生态剂量筛查阿尔及利亚El Kala国家公园土壤中的天然和人工放射性核素浓度的基线研究
Mohamed Ziouche,Djamel Taieb Errahmani,Mouad Boudria et al.
Mohamed Ziouche et al.
Twenty-eight composite surface soil samples collected from four ecosystem types across El Kala National Park, Algeria - a United Nations Educational, Scientific and Cultural Organization (UNESCO) Biosphere Reserve. UNESCO Biosphere Reserve ...
EURADOS WG10 2019 field test of retrospective dosimetry methods: The NRPI results of mobile phones and salt dosemeters [0.03%]
EURADOS工作组10现场测试报告(一):NRPI移动电话和盐剂量仪结果分析
Zina Čemusová,Daniela Ekendahl
Zina Čemusová
Various methods of physical retrospective dosimetry based mainly on thermally and optically stimulated luminescence in daily-use items are employed to assess the dose after unplanned radiation exposure. The investigations are usually perfor...
Characterization and calibration of a portable HPGe detector for in situ gamma-ray spectrometry using large-sized calibration pads [0.03%]
大尺寸标定垫用于便携式HPGe探测器原位伽马能谱测量表征及刻度研究
Haluk Yücel,Mine Özgür,Hasan Dikmen
Haluk Yücel
For in situ gamma-ray spectroscopy, a study was performed for characterization of a portable high-purity germanium (HPGe) detector utilizing four large-sized concrete pads, which were already used for the calibration of airborne gamma-ray d...
Establishing typical diagnostic reference levels in a Peruvian nuclear medicine centre: a retrospective study [0.03%]
建立秘鲁核医学中心典型诊断参考水平的回顾性研究
Paul Elias Panizo-Olivos,Cecilia Querebalú-García,Eduardo Garnique-Millones et al.
Paul Elias Panizo-Olivos et al.
Diagnostic reference levels (DRLs) are tools for optimizing medical exposures. We performed a retrospective analysis of 898 adult scintigraphic examinations acquired between 2018 and 2024 at a Peruvian hospital to establish institutional DR...
Establishment of typical values in computed tomography to support the optimization of protection in clinical practice [0.03%]
基于临床实践中的辐射防护优化建立CT影像学典型值规范研究
Diogo Madaleno,Cecília Borges,Inês Pereira et al.
Diogo Madaleno et al.
Typical values, as defined by the International Commission on Radiological Protection, support the optimization of protection in Computed Tomography (CT). They provide comparisons when new technologies are introduced, as well as for assessi...
Exposure of the palm to handheld wireless devices operating at frequencies from 900 MHz to 6 GHz [0.03%]
手机等手持无线设备对人体手掌的电磁辐射暴露研究(900MHz-6GHz)
Andreas Christ,Kai Niskala,Kenneth H Joyner
Andreas Christ
The exposure of the palm due to handheld wireless devices is analyzed using anatomical hand models of adults and children considering a frequency range from 900 MHz to 6000 MHz. The fingers of the hand models are articulated such that they ...
Toxicity and risk after using new modalities of radiotherapy in Algeria: retrospective intercomparison study [0.03%]
阿尔及利亚开展新型放疗后的毒副作用和风险:回顾性比较研究
Assya Boughalia,Mohamed Fellah,Zineddine El Ghribi et al.
Assya Boughalia et al.
This study aims to assess different advanced treatments modalities in terms of their toxicity NTCPs and the induced second primary cancers excess absolute risk (EARs) using in-house software "COUPOLE" in case of prostate cancer. A total of ...
Comparative Study
Radiation protection dosimetry. 2026 Jun 3;202(9):713-719. DOI:10.1093/rpd/ncaf197 2026
Sensitivity analysis of neutron and photon equivalent doses in patient organs during 3D conformal radiotherapy using Monte Carlo simulations [0.03%]
基于蒙特卡罗模拟的三维适形放射治疗中患者器官中的中子和光子等效剂量敏感度分析
Asma Alem-Bezoubiri,Fethi Bezoubiri,Michael Speiser et al.
Asma Alem-Bezoubiri et al.
This study evaluates neutron and photon equivalent dose sensitivity in patient organs during prostate three-dimensional conformal radiotherapy (3DCRT) using Monte Carlo simulations. A validated Varian Clinac 2100C LINAC model and a hybrid X...
Safety analysis of the NuScale Small Modular Reactor: steady-state qualification and small break loss of coolant accident simulation using RELAP5/SCDAPSIM3.4 [0.03%]
NuScale小型模块化反应堆的安全分析:稳态鉴定及一回路小破口丧失冷却实验的RELAP5/SCDAPSIM3.4模拟计算
Ahmed Hadjam,Djillali Saad,Amina Lyria Deghal Cheridi et al.
Ahmed Hadjam et al.
This paper presents a comprehensive safety analysis of the NuScale Small Modular Reactor, a next-generation nuclear technology. The NuScale design emphasizes enhanced safety, flexibility, and efficiency, achieved through a natural circulati...
Effect of gamma irradiation dose on the adsorption kinetics of Rovamycin by a composite material [0.03%]
γ射线剂量对复合材料吸附罗瓦霉素动力学的影响研究
Malika Arabi-Hocine,Khedoudja Remil,Belkacem Mansouri et al.
Malika Arabi-Hocine et al.
The present study focuses on the effect of the gamma irradiation dose on the adsorption kinetics of Rovamycin by composite materials. The retention of this antibiotic is closely related to this parameter. The equilibrium plateau begins to a...