Durable left ventricular assist devices in pediatrics: impact of body size on outcomes and size limitations [0.03%]
儿科植入式左心室辅助装置的效果与患儿体型的关系及装置尺寸的限制
Mimi Xiaoming Deng,Nao Yoshida,Christoph Haller et al.
Mimi Xiaoming Deng et al.
Despite the range of body sizes in children, few ventricular assist devices (VAD) exist to support pediatric patients with end-stage heart failure. Large registry data identified weight < 20 kg to be associated with higher rates of VAD-rela...
HeartMate 3 driveline damage by gradual corrosion due to liquid infiltration: a case report [0.03%]
液体渗入导致的心力衰竭治疗装置HeartMate 3输液管腐蚀断裂1例报告
Tomo Yoshizumi,Hideki Ito,Sachie Terazawa et al.
Tomo Yoshizumi et al.
A 31-year-old man with a HeartMate 3 was admitted with a "Driveline Communication Fault" alarm due to liquid infiltration. Eleven months earlier, the connector between the modular and pump cables had gotten wet when he was taking a shower. ...
A case of successful surgical treatment of left ventricular thrombus associated with acute myocardial infarction by Impella combined with extracorporeal membrane oxygenation approach [0.03%]
左主干冠心病急性前壁心梗合并恶性室性心律失常的外科治疗一例
Rieko Kutsuzawa,Naoki Tadokoro,Satoshi Kainuma et al.
Rieko Kutsuzawa et al.
The mortality rate in patients with heart failure complicated by cardiogenic shock following acute myocardial infarction (AMI) remains high, prompting research on mechanical circulatory support. Improved mortality rates have been reported w...
Computational fluid dynamics simulating of the FDA benchmark blood pump with different coefficient sets and scaler shear stress models used in the power-law hemolysis model [0.03%]
不同幂律溶血模型系数和剪切应力模型对FDA标准血液泵模拟影响的计算流体动力学研究
Ahmet Onder,Omer Incebay,Rafet Yapici
Ahmet Onder
Hemolysis is the most important issue to consider in the design and optimization of blood-contacting devices. Although the use of Computational Fluid Dynamics (CFD) in hemolysis prediction studies provides convenience and has promising pote...
Characterization of anisotropic pore structure and dense selective layer of capillary membranes for long-term ECMO by cross-sectional ion-milling method [0.03%]
用于长期ECMO的 капillary膜各向异性孔隙结构和致密选择层的表征
Makoto Fukuda,Kazunori Sadano,Tomoki Maeda et al.
Makoto Fukuda et al.
Since the COVID-19 pandemic of 2020-2023, extracorporeal membrane oxygenator (ECMO) has attracted considerable attention worldwide. It is expected that ECMO with long-term durability is put into practical use in order to prepare for next em...
Nasser K Awad
Nasser K Awad
Human body constitutes unique biological system containing specific fluid mechanics and biomechanics. Traditional cell culture techniques of 2D and 3D do not recapitulate these specific natures of the human system. In addition, they lack th...
Critical hematological parameters in bleeding during extracorporeal membrane oxygenation support [0.03%]
体外膜氧合支持过程中出血的关键血液参数分析
Ngan Hoang Kim Trieu,Tuan Anh Mai,Huy Minh Pham
Ngan Hoang Kim Trieu
Bleeding complications are frequently observed in patients undergoing extracorporeal membrane oxygenation and are associated with increased mortality. Due to the complex mechanisms, managing bleeding during ECMO remains a challenge. Acquire...
The foremost and greatest barrier to end-stage heart failure treatment: the impact of caregiver shortage [0.03%]
终末期心力衰竭治疗的最大阻碍:护理人员短缺的影响
Shunsuke Saito,Daisuke Yoshioka,Takuji Kawamura et al.
Shunsuke Saito et al.
We examined the number of patients abandoning cardiac replacement therapy due to the inability to secure a designated caregiver. At Osaka University Hospital Heart Center, when we receive a consultation for a patient with severe heart failu...
Relation between antithrombin-III activity and activated clotting time for cardiopulmonary bypass [0.03%]
体外循环中抗凝血酶-Ⅲ活性与激活凝血时间的关系研究
Tomoaki Yamashiro,Yoshiyuki Takami,Yasushi Takagi
Tomoaki Yamashiro
Heparin resistance (HR) is observed before cardiopulmonary bypass (CPB), despite with normal antithrombin III (AT-III) levels. The relationships between preoperative AT-III activity and activated clotting time (ACT) after the first heparin ...
Effect of online hemodiafiltration on quality of life, fatigue and recovery time: a systematic review and meta-analysis [0.03%]
在线血透滤过对生活质量、疲劳和恢复时间影响的系统评价及meta分析
Maurizio Bossola,Ilaria Mariani,Manuela Antocicco et al.
Maurizio Bossola et al.
The present systematic review and meta-analysis aims to compare the effect of bicarbonate hemodialysis and HDF on quality of life (QoL), fatigue, and time to recovery in end-stage renal disease (ESRD) patients. Searches were run on January ...