Sustained postoperative elevation of ionized magnesium levels following cardiac surgery with magnesium-enriched cardioplegia: a prospective observational study [0.03%]
富镁心肌保护液心脏手术后术后血离子镁持续升高的一项前瞻性观察研究
Satoshi Kometani,Shiro Matsuo,Tomohide Takei et al.
Satoshi Kometani et al.
This study aimed to clarify perioperative changes in ionized magnesium levels (iMg), a physiologically active fraction, and particularly the persistence of hypermagnesemia at the time of extubation in cardiac surgery using magnesium-enriche...
Hepatitis A vaccination during ventricular assist device support in heart transplant candidates: immunogenicity and safety in a single-center cohort [0.03%]
左心室辅助装置支持状态下接种甲型肝炎疫苗在心脏移植受者中的免疫原性和安全性:单中心队列研究
Masahiro Arima,Shinya Yamamoto,Maho Adachi-Katayama et al.
Masahiro Arima et al.
Vaccination is among the cornerstones of infectious disease prevention in heart transplant candidates and recipients. Guidelines recommend an inactivated hepatitis A virus vaccine for heart transplant candidates, many of whom are on ventric...
From guidance to reliable practice: an auditable hemocompatibility cockpit for outpatient HeartMate 3 care [0.03%]
从指导到可靠实践:一种可审计的血液相容性驾驶舱用于门诊HeartMate 3护理
Arif Albulushi,Gamal Aly,Hatem Farhan
Arif Albulushi
Centrifugation-based plasma exchange overcomes blood flow restriction to rescue hyperviscosity syndrome in IgM-κ multiple myeloma: a case report [0.03%]
基于离心的血浆置换克服了血流限制以救治IgM-κ型多发性骨髓瘤高黏滞血症:病例报告
Hiroto Osakabe,Shinkuro Yamamoto,Ryu Shigehisa et al.
Hiroto Osakabe et al.
When blood flow cannot be raised to the 150-200 mL/min threshold required for membrane-based therapeutic plasma exchange, centrifugation-based therapeutic plasma exchange represents the only mechanistically viable option-yet this specific c...
Successful destination therapy after stepwise mechanical circulatory support in a patient with cardiogenic shock following mechanical aortic valve replacement [0.03%]
逐步机械循环支持后成功进行目的地治疗的一例心脏骤停患者的人工主动脉瓣置换术后的研究
Rina Ebe,Tatsuki Fujiwara,Eiki Nagaoka et al.
Rina Ebe et al.
Patients with mechanical aortic valve replacement and end-stage heart failure present major challenges when mechanical circulatory support is required, as transvalvular devices such as the Impella 5.5 are contraindicated. We report a 57-yea...
Considerations and future challenges in managing ECMO for pediatric patients [0.03%]
儿科ECMO支持的管理考量和未来挑战
Koichi Kashiwa,Kent Doi,Fumiaki Shikata et al.
Koichi Kashiwa et al.
In managing ECMO, preventing thrombus formation and hemolysis is crucial. While centrifugal pumps are increasingly used in pediatric ECMO, pumps designed for low flow range are not approved in Japan. Thus, centrifugal pumps for adults are u...
Correlation between real sieving coefficient determined using novel lab-scale module and pore structure of hemodiafiltration membranes [0.03%]
一种新型实验室规模模块测定的血液透析滤过膜真实筛系数与其孔结构之间的关系
Mizuki Ichikawa,Makoto Fukuda,Takuma Morikawa et al.
Mizuki Ichikawa et al.
The novel lab-scale hollow fiber membrane module was fabricated to determine the apparent sieving coefficient ([Formula: see text]) of commercial hemodiafiltration membranes, MFX-SW eco (polyethersulfone, Sample A) and NVF-P (polysulfone, S...
Adsorption characteristics of erythropoietin in two β2-microglobulin absorption systems: a preliminary in vitro study using FILTOR® and Lixelle® [0.03%]
重组人促红细胞生成素在FILTOR和LIXELLE系统中吸附特性的体外研究
Shoichiro Hara,Masakazu Hirose,Taisuke Goto et al.
Shoichiro Hara et al.
Purpose: To compare the erythropoietin adsorption characteristics of two adsorption devices, Lixelle® and FILTOR®, used for the treatment of dialysis-related amyloidosis, using bovine serum. ...
Extracorporeal life support for severe heart failure in a diffuse panbronchiolitis patient awaiting lung transplant: a case report [0.03%]
一例等待肺移植的弥散性泛细支气管炎患者重度心力衰竭体外生命支持治疗的个案报道
Yoshikazu Kimura,Shuji Okahara,Haruki Sunami et al.
Yoshikazu Kimura et al.
A 55-year-old woman with chronic respiratory failure due to diffuse panbronchiolitis, on a lung transplant waitlist, developed acute left ventricular failure with an ejection fraction of 18%. Although cardiac reversibility was uncertain, it...
Investigation of the cleaning effect by the intermittent backfiltration in diafilters with polysulfone and polymethylmethacrylate membranes [0.03%]
聚砜和聚甲基丙烯酸甲酯膜截留袋间歇反滤清洗效果的研究
Takayoshi Kiguchi,Ayaka Tanuma,Akihiro C Yamashita
Takayoshi Kiguchi
An intermittent infusion during dialysis therapy across the membrane by backfiltration is expected to have a cleaning effect on the membrane in addition to stabilizing blood pressure. In this study, the effect of backfiltration infusion on ...