Disparities in Defibrillator Implantations during COVID-19: Insights from the NCDR registry [0.03%]
新冠肺炎期间除颤器植入的差异:来自NCDR登记处的见解
Saima Karim,Rachel Lampert,Kevin Kennedy et al.
Saima Karim et al.
Development and Validation of a Novel Machine Learning-Based Algorithm to Predict Incident Atrial Fibrillation - A Multicohort Analysis [0.03%]
一种预测新发房颤的新型机器学习算法的开发和验证——多队列分析
Matthew W Segar,Neil Keshvani,Byron Jaeger et al.
Matthew W Segar et al.
Background: Existing atrial fibrillation (AF) risk prediction models incorporate race as a covariate, systematically underestimating AF risk in Black individuals and potentially perpetuating healthcare disparities. ...
Effectiveness and safety of upgrading to conduction system pacing compared with biventricular pacing in patients with pacing-induced cardiomyopathy: Results of a propensity score-matched analysis from a multicenter registry [0.03%]
起搏器治疗心肌病患者传导系统起搏与双心室起搏疗效和安全性的对比研究:一项基于多中心注册登记的倾向性匹配分析结果
Pietro Palmisano,Gabriele DellEra,Matteo Ziacchi et al.
Pietro Palmisano et al.
Background: Upgrading to biventricular pacing (BVP) is currently the standard treatment for pacing-induced cardiomyopathy (PICM) patients. Although emerging literature suggests that upgrading to conduction system pacing (...
Steam Pops during Temperature Controlled Irrigated Radiofrequency Ablation using the Lattice-tip Catheter [0.03%]
使用晶格电极导管进行温度控制 irrigate 射频消融过程中的蒸汽爆破现象
Jacob S Koruth,Timothy R Maher,Vivek Reddy et al.
Jacob S Koruth et al.
Empirical Cryoballoon-Based Left Atrial Appendage Isolation Followed by Closure, Including Cases with LAA Thrombosis, in Persistent Atrial Fibrillation Patients with Durable Pulmonary Vein Isolation: Feasibility and Long-Term Outcomes (CB-LAAI + LAAC after Durable PVI in Persistent AF) [0.03%]
基于经导管 cryoballoon 左心耳隔离和闭塞的临床研究(包括左心耳血栓),对持续性房颤且肺静脉隔离效果良好的患者:可行性和长期疗效(CB-LAAI + LAAC after Durable PVI in Persistent AF)
Tolga Han Efe,Ramin Ebrahimi,David Schaack et al.
Tolga Han Efe et al.
Background: Left-atrial-appendage-isolation (LAAI) may improve rhythm-outcomes in atrial fibrillation (AF) but raises concerns regarding safety and thromboembolic risk. ...
Prevalence of arrhythmia-induced cardiomyopathy: A systematic review and meta-analysis [0.03%]
心律失常性心肌病的患病率:系统评价和 Meta 分析
Teodor Serban,Tatjana Müller,Sven Knecht et al.
Teodor Serban et al.
Background: Arrhythmia-induced cardiomyopathy (AiCM) is a reversible cause of left ventricular systolic disfunction (LVSD) that arises from sustained cardiac arrhythmias. Despite its clinical significance, AiCM has tradit...
Artificial intelligence-enabled electrocardiographic sex discordance and the risk of incident atrial fibrillation: a multi-national cohort study [0.03%]
基于人工智能的ECG性别不一致与房颤发病风险的相关性:一项跨国队列研究
Hanjin Park,Oh-Seok Kwon,Dong Won Kim et al.
Hanjin Park et al.
Background: Binary classification of sex fails to capture the sex-related continuum of atrial fibrillation (AF) risk. Objective: To dev...
High Subcutaneous Nerve Activity in Noise-Associated Ventricular Arrhythmias [0.03%]
与噪声相关的心室心律失常的高皮下神经活性
Chao-Yi Chen,Chia-Hao Kuo,Tien-Chi Huang et al.
Chao-Yi Chen et al.
Background: Linked to autonomic nervous system (ANS) dysregulation, environmental noise is a contributing factor to cardiovascular disease and arrhythmias. Subcutaneous nerve activity (SCNA) and heart rate variability (HR...
Temporal Change in Right Ventricular Pacing Ratio and Its Association with Cardiac Function and Arrhythmia: A Linear Mixed-Effects Model Analysis [0.03%]
右心室起搏比例的时间变化及其与心脏功能和心律失常的关系:线性混合效应模型分析
Naoya Inoue,Shuji Morikawa,Yuji Ito et al.
Naoya Inoue et al.
Background: Right ventricular pacing (RVP) induces electrical and mechanical dyssynchrony, possibly influencing left ventricular (LV) dysfunction and heart failure. However, the impact of temporal increases in the RVP rat...
Innovative Approach to Conduction System Pacing: Real-time ECG Imaging guidance for precise Left Bundle Branch Area Pacemaker lead placement [0.03%]
实时ECG影像引导下精准左束支区域起搏电极植入术
Ivan Eltsov,Ingrid Overeinder,Luigi Pannone et al.
Ivan Eltsov et al.
Background: Left Bundle branch area pacing is currently the procedure of choice for various indications including atrioventricular block and considered to be physiologic modality of pacing compared to RV apex pacing espec...