Hyoyi Kim,Seoyoung Lee,Seungryong Cho
Hyoyi Kim
Background: Machine learning models for chest X-ray (CXR)-based tuberculosis (TB) detection often suffer from performance drops when deployed across institutions due to domain shifts caused by differences in patient popul...
Dual-energy CT for proton therapy: Impact of advanced slice-wise patient-thickness estimation methods for improved stopping-power prediction [0.03%]
基于先进层厚估计方法的双能量CT在质子治疗中的作用研究:改善射程预测
Julian Schwengfelder,Nils Peters,Patrick Wohlfahrt et al.
Julian Schwengfelder et al.
Background: The direct prediction of stopping-power ratio (SPR) from dual-energy CT (DECT) has become gold-standard in proton therapy. Remaining uncertainties due to patient-size-specific CT number variations are mitigate...
Optimization of CBCT-guided imaging schedules for left-sided postmastectomy radiotherapy using VMAT: A dosimetric, radiobiological, and cost analysis [0.03%]
基于VMAT的左侧乳腺癌术后容积调强放疗CBCT引导摆位影像优化研究:剂量学,放射生物及成本分析
Denghong Liu,Changxu Lu,Xueyi Zou et al.
Denghong Liu et al.
Purpose: This study aimed to determine an appropriate frequency of image-guided (IG) schedules for left-sided postmastectomy radiotherapy by comprehensively evaluating dosimetric, radiobiological, imaging dose, and imagin...
Quantitative phantom-based comparison of commercial CT metal artifact reduction algorithms [0.03%]
商用CT金属伪影减少算法的定量体模比较研究
Beechui Koo,Daehong Kim,Hyunuk Jung et al.
Beechui Koo et al.
Background: Metal artifacts in computed tomography (CT) significantly compromise image quality and CT number (CTN) accuracy, which may influence downstream applications such as radiation therapy workflows. Although commer...
Comparative Study
Journal of applied clinical medical physics. 2026 May;27(5):e70631. DOI:10.1002/acm2.70631 2026
Evaluation of the reliability of markerless tumor tracking with single-energy and dual-energy imaging using machine learning [0.03%]
基于机器学习的单能量和双能量成像无标记肿瘤跟踪可靠性的评估研究
Ha Nguyen,Jason Luce,Liangjia Zhu et al.
Ha Nguyen et al.
Background: Markerless tumor tracking (MTT) using single-energy (SE) kilovoltage (kV) imaging has been proposed as a technique for lung tumor motion management. However, bony structures can obscure the tumor and make trac...
Beyond TG‑43: A PRISMA-based systematic review on model-based dose-calculation algorithms in brachytherapy [0.03%]
超越TG-43:基于PRISMA的后装治疗模型剂量计算算法系统性研究
Dat Tran,Thanh-Tai Duong,Shada Wadi-Ramahi et al.
Dat Tran et al.
Background and purpose: The AAPM TG-43 formalism has long served as the clinical standard for brachytherapy dose calculation but assumes a homogeneous water equivalent medium, overlooking limited scattering conditions and...
Parallel/Opposed: Automated treatment planning systems should be designed to minimize human intervention [0.03%]
化而为之:自动化治疗计划系统的设计应尽量减少人为干预
Carlos E Cardenas,Joseph Harms,Dongxu Wang
Carlos E Cardenas
Increasing efficiency in the ACR Digital Mammography QC Manual's DBT Z-resolution evaluation [0.03%]
提高ACR数字乳腺摄影QC手册的DBT Z分辨率评估的效率
Ryan F Fisher,Nicholas B Bevins,Katie W Hulme et al.
Ryan F Fisher et al.
Background: The Z-resolution evaluation in the ACR Digital Mammography (DM) QC manual measures a pseudo full width half max (pFWHM) from speck group signals through slices of the phantom for comparison to a baseline value...
Synthetic CT imaging for pelvic and abdominal MR-only radiotherapy: Clinical validation on a 1.5T MR-Linac [0.03%]
基于1.5T磁共振直线加速器的MR引导放疗中盆腔和腹部合成CT成像的临床验证研究
Colin Gaban,Olivier Pisaturo,Raphael Moeckli et al.
Colin Gaban et al.
Background: Magnetic Resonance (MR)- only workflows are fundamentally limited by the absence of electron density information required for accurate photon dose calculations, necessitating supplementary CT imaging. Syntheti...