A pathway away from measurement-based patient-specific QA: A review of contemporary quality assurance for external-beam radiotherapy sub-systems [0.03%]
从基于测量的患者特定质保到当代常规放疗亚系统质保之路:综述
Michael Barnes
Michael Barnes
Background: Prior to the development of the IMRT and VMAT treatment techniques the quality assurance (QA) paradigm was one of routine linac QA supplemented by plan specific independent Monitor Unit checks and manual check...
Arash Darafsheh,Hamid Ghaznavi
Arash Darafsheh
Radiochromic films (RCFs) are ubiquitous in radiation oncology clinical and research settings to measure the radiation dose over a two-dimensional (2D) area due to their high spatial resolution, water-equivalency, and relative ease-of-use. ...
Fast and accurate measurement of small field dosimetry using a novel scintillation detector [0.03%]
一种新型闪烁探测器在小野剂量学快速准确测量中的应用研究
Yiding Han,Jingzhu Xu,Yao Hao et al.
Yiding Han et al.
Background: The most used instruments for small-field dosimetry have notable limitations, including the need for correction of output factors, limited scanning speeds, and challenges in alignment for percentage depth dose...
Evaluation of treatment planning feasibility of a positron emission tomography (PET)-Linac system for spine stereotactic body radiotherapy (SBRT) [0.03%]
正电子发射断层扫描-直线加速器系统脊柱立体定向体放射治疗计划的可行性研究
Haozhao Zhang,Shunyu Yan,Hao Peng et al.
Haozhao Zhang et al.
Background and purpose: The RefleXion X1 (RefleXion Medical, Inc., Hayward, CA) is a unique radiotherapy platform integrating kVCT and PET as on-board imaging guidance. This study aims to evaluate the feasibility and trea...
Stratified dosimetric comparison between high-definition multileaf collimator-based D2SRS and robotic radiosurgery in the treatment of brain metastases [0.03%]
基于高清晰度多叶准直器的D2SRS与机器人放射外科治疗脑转移瘤的分层剂量学比较研究
Canyang Lin,Wei Liu,Nan Xiao et al.
Canyang Lin et al.
Purpose: To compare dosimetric characteristics and treatment efficiency between the high-definition multileaf collimator (HD-MLC) system and robotic radiosurgery (RRS) for brain metastases, with stratified analysis by les...
Comparative Study
Journal of applied clinical medical physics. 2025 Dec;26(12):e70361. DOI:10.1002/acm2.70361 2025
HyperSight CBCT image quality and metal artifact reduction for adaptive head and neck radiotherapy: Results from a prospective clinical trial [0.03%]
一种用于头颈部自适应放疗的CBCT成像质量及伪影减少技术:前瞻性临床试验结果分析
Abby Yashayaeva,R Lee MacDonald,Kenny Zhan et al.
Abby Yashayaeva et al.
Background: Accurate Hounsfield units (HU) are critical for dose calculation and anatomical visualization, but are often affected by dental artifacts in head and neck (H&N) cancer patients. The HyperSight cone-beam comput...
Clinical application of 3D-printed bolus in postmastectomy radiotherapy [0.03%]
三维打印射野袖套在乳腺癌术后放疗中的应用
Qianqian Liu,Xuming Chen,Zhekai Hu et al.
Qianqian Liu et al.
Purpose: To evaluate the fitting accuracy and dose influence of 3D-printed bolus (3DPB) during postmastectomy radiotherapy. Methods: Ai...
The culture of JACMP, the sanctity of editorial independence, and why your ego is not your amigo [0.03%]
JACMP的文化、编辑独立的圣神地位以及为什么你不需要自以为是的朋友
Michael D Mills
Michael D Mills
Development and evaluation of deep learning models for estimating the organ at-risk dose constraint from two-dimensional cine magnetic resonance imaging scans during irradiation [0.03%]
基于放疗期间二维心磁共振图像的危及器官剂量限制的深度学习模型的发展和评估
Shohei Tanaka,Noriyuki Kadoya,Wingyi Lee et al.
Shohei Tanaka et al.
Purpose: Two-dimensional (2D) cine magnetic resonance imaging (MRI), available with a MR-linear accelerator (MR-Linac), allows real-time visualization of anatomical information during irradiation. The present study aimed ...
Dosimetric evaluation of magnetic resonance imaging based synthetic computed tomography for head and neck photon and proton therapy [0.03%]
基于磁共振成像的合成CT在头颈光子和质子放疗中的剂量学评价研究
Marte Kåstad Høiskar,René M Winter,Natalie Hornik et al.
Marte Kåstad Høiskar et al.
Background: Accurate target delineation is essential for precise delivery of proton therapy. A magnetic resonance imaging (MRI)-only radiotherapy workflow may improve delineations, and thus improve proton therapy, but req...