Should a pooled analysis of FDA trials be considered representative for a population? [0.03%]
汇集的FDA试验数据能否代表总体人群?
Piotr Kanclerz,Jordan Masters
Piotr Kanclerz
Intra-session repeatability of anterior chamber depth across the chamber width using Pentacam Scheimpflug imaging in healthy subjects [0.03%]
健康受试者使用Pentacam Scheimpflug摄像仪测量房水深度的重复性
Jack Phu,Janelle Tong,Michael Kalloniatis
Jack Phu
Purpose: Despite the importance of anterior chamber depth (ACD) measurements in disease and ageing, the repeatability and their threshold for change is not known. Our purpose was to determine the intra-session repeatabili...
Wide-field choroidal thickness and vascularity index in myopes and emmetropes [0.03%]
近视眼和正视眼的脉络膜厚度及血管指数
Negareh Yazdani,Asieh Ehsaei,Hosein Hoseini-Yazdi et al.
Negareh Yazdani et al.
Purpose: To study regional variations in choroidal thickness (CT), luminal thickness and stromal thickness of the choroid, and choroidal vascularity index (CVI) in low myopic and emmetropic eyes using wide-field optical c...
A validated finite element model to reproduce Helmholtz's theory of accommodation: a powerful tool to investigate presbyopia [0.03%]
一种验证过的有限元模型以重现亥姆霍兹的调节理论:研究老视的强大工具
Iulen Cabeza-Gil,Jorge Grasa,Begoña Calvo
Iulen Cabeza-Gil
Purpose: To reproduce human in vivo accommodation numerically. For that purpose, a finite element model specific for a 29-year-old subject was designed. Once the proposed numerical model was validated, the decrease in acc...
Investigating the discrepancy between MAIA and MP-1 microperimetry results [0.03%]
探究MAIA与MP-1微视野检查结果差异的原因
Lixing Xu,Zhichao Wu,Robyn H Guymer et al.
Lixing Xu et al.
Purpose: Previous work has suggested that sensitivities measured on the iCare MAIA and Nidek MP-1 microperimeters differ systematically, although it is unclear whether one or both devices are inaccurate. Here, we assess t...
Gregory P Hindmarsh,Alex A Black,Sonia Lj White et al.
Gregory P Hindmarsh et al.
Purpose: Eye movements are integral to the reading process. This study characterised the eye movement patterns of children differentiated by their reading ability, while completing a saccadic eye movement test with irregu...
David A Atchison,Jos J Rozema
David A Atchison
Purpose: Approaches are developed to determine relative retinal magnifications in anisometropic patients undergoing cataract surgery; these can be used to balance between full spectacle corrections with equal intraocular ...
Achim Langenbucher,Timo Eppig,Alan Cayless et al.
Achim Langenbucher et al.
Purpose: Using raytracing simulation to study the effect of corneal imaging metrics for different aperture sizes as a function of object distances with different schematic model eyes. ...
Comparing the CamBlobs2 contrast sensitivity test to the near Pelli-Robson contrast sensitivity test in normally-sighted young adults [0.03%]
比较正常视力的年轻人中的CamBlobs2对比敏感度检查和近用Pelli-Robbin对比敏感度检查
Sujata Rijal,Han Cheng,Jason D Marsack
Sujata Rijal
Purpose: Contrast sensitivity (CS) has been proposed as a potential method for patients to assess their vision at home. The CamBlobs2 contrast sensitivity test is meant to be performed easily in the clinic or at home. The...
Francisco Lara-Lacárcel,Iván Marín-Franch,Vicente Fernández-Sánchez et al.
Francisco Lara-Lacárcel et al.
Purpose: Previous studies have shown small but clinically significant changes in the power and axis of astigmatism when the eye accommodates. Monocular objective measurements of the eye during accommodation, when the obje...