Correction: Associations between iron and mean kurtosis in iron-rich grey matter nuclei in aging [0.03%]
有关铁含量与灰质核磁平均峰度值随衰老变化关联的更正:铁丰富的灰质核磁异常研究
Jason Langley,Kitzia Solis,Vala Masjedizadeh et al.
Jason Langley et al.
Published Erratum
Magma (New York, N.Y.). 2026 Aug 1. DOI:10.1007/s10334-026-01393-0 2026
Differentiation between glioblastomas and solid brain metastases using amide proton transfer-weighted (APTw) MRI with and without fluid suppression [0.03%]
利用含水量抑制前后的酰胺质子转移加权(APT w )MRI区分胶质母细胞瘤和实质性脑转移灶
Malte Knutsson,Tim Salomonsson,Anina Seidemo et al.
Malte Knutsson et al.
Object: Accurate differentiation between glioblastomas (GBM) and solitary brain metastases (MET) is crucial for treatment planning. This study evaluated the ability of amide proton transfer-weighted (APTw) MRI with and wi...
On z-shimming of non-linear and inhomogeneous through-slice field variations: insights from numerical simulations [0.03%]
关于非线性和不均匀的 slice通过场变化的z向修正:从数值模拟中得到的观点
Jürgen Finsterbusch
Jürgen Finsterbusch
Objective: T2*-weighted acquisitions used for functional neuroimaging suffer from signal losses in the presence of field inhomogeneities due to through-slice dephasing that can be ameliorated with so-called z-shim gradien...
Actuated dose delivery and physiological monitoring of 129Xe MRI: implications for improving repeatability [0.03%]
用于129Xe磁共振成像的促动给药和生理监测:提高重复性的意义
Drew Clements,Suphachart Leewiwatwong,Anna Costelle et al.
Drew Clements et al.
Objective: Identify and quantify physiological sources of variability in hyperpolarized 129Xe gas-exchange MRI and present a dose-delivery workflow that promotes repeatable lung inflation and alveolar pressure during imag...
Estimation of skin sodium content via 23Na magnetic resonance imaging at 3 T using a single-loop surface transmit/receive coil [0.03%]
利用单环表面发射/接收线圈在3T下基于23Na磁共振成像的皮肤钠含量估算
Jonathan Richard Birchall,Joshua Daniel Kaggie,Frank Riemer et al.
Jonathan Richard Birchall et al.
Objective: To assess the feasibility of performing quantitative in vivo tissue sodium concentration measurements in the skin with MRI using a sodium-tuned single-loop transmit/receive surface coil at 3 T. ...
Effect of salts on phase transition in native tendon collagen - an NMR study [0.03%]
盐对原生腱胶原相变的影响——核磁共振研究
Alexander M Panich
Alexander M Panich
Objective: This study aimed to investigate the effect of NaCl and KCl salts on the phase transition in native collagen. Materials and methods: ...
Evaluation of high-fat diet-induced metabolic impairments in iBAT lipid metabolism using 1H-MRS [0.03%]
1H-MRS评估高脂饮食诱导的代谢障碍对iBAT脂质代谢的影响
Anantharaj Rengaraj,Giang Thi Thu Le,Chandan Dharmashekar et al.
Anantharaj Rengaraj et al.
Background: High-fat diet (HFD) feeding impairs interscapular brown adipose tissue (iBAT) mitochondrial function, leading to lipid accumulation and insulin resistance. ...
Optimal cardiac phase selection using motion-sensitive cine imaging improves T2w-STIR image quality in cardiac MRI [0.03%]
利用运动敏感电影成像选择最佳心脏时相可提高心脏MRI的T2w-STIR图像质量
Yoshihiko Tachikawa,Chisato Ando,Risa Ishikawa et al.
Yoshihiko Tachikawa et al.
Objective: Cardiac T2-weighted short-tau inversion recovery (T2w-STIR) is highly susceptible to myocardial motion, and acquisition at inappropriate cardiac phases can cause myocardial signal loss and inhomogeneity. This s...
Online image reconstruction via Multiple Orthogonal Reference Sensitivity Encoding (MORSE) [0.03%]
基于多重正交参考敏感度编码的在线图像重建技术(MORSE)
Oliver Josephs,Barbara Dymerska,Nadine N Graedel et al.
Oliver Josephs et al.
Objective: Parallel imaging is ubiquitous in MRI, enabling higher spatial and/or temporal resolution. However, successful unfolding is contingent on robust and accurate estimation of relative coil sensitivities, which oft...
Correction: MRS4Brain: a software for preclinical proton and deuterium-based MR spectroscopic imaging data [0.03%]
纠正:MRS4Brain:一款用于基于质子和氘的磁共振波谱成像数据的软件
Brayan Alves,Tan Toi Phan,Guillaume Briand et al.
Brayan Alves et al.
Published Erratum
Magma (New York, N.Y.). 2026 Jul 3. DOI:10.1007/s10334-026-01377-0 2026