R Mudgett
R Mudgett
The use of electromagnetic energy in food processing is reviewed with respect to food safety, nutritional quality, and organoleptic quality. The effects of nonionizing radiation sources such as microwave and radio-frequency energy and ioniz...
Bacterial survival and thermal responses of beef loaf after microwave processing [0.03%]
微波处理对牛肉饼中细菌存活及热响应的影响
W Lin,C Sawyer
W Lin
The effects of wrapping product in polyvinylidene chloride (PVDC) film, load size (150, 600 and 1200 g loaves), microwave output power (713 +/- 5 W and 356 +/- 3 W at 2450 MHz) and processing time on bacterial survival were evaluated in bee...
R A Budd,P Czerski
R A Budd
There have been reports that electromagnetic radiation (EMR) alters the function of the immune system; however, these reports are often contradictory. This review reexamines the literature and attempts to evaluate the data on potential mech...
Long-term study of 435 MHz radio-frequency radiation on blood-borne end points in cannulated rats. Part II: methods, results, and summary [0.03%]
435MHz射频辐射对插管大鼠血源性指标长期影响的研究(第2部分):方法、结果及总结
J Toler,V Popovic,S Bonasera et al.
J Toler et al.
This study investigated the effects of long-term, low-level exposure to radio-frequency radiation (RFR) on various physiological systems in a large rodent population. Two hundred adult male white rats with chronically implanted aortic cannu...
Preclinical evaluation of submillimeter diameter microwave interstitial hyperthermia applicators [0.03%]
亚毫米直径微波插入式热疗导管的临床前评价研究
C Gottlieb,F Moffat,M Hagmann et al.
C Gottlieb et al.
Ultra miniature coaxial cable has been used, with microscopic techniques, to fabricate interstitial hyperthermia applicators having diameters of 0.20 mm, 0.33 mm, and 0.58 mm; commercial applicators have a diameter of 1.1 mm. Animal studies...
Feasibility study of monitoring temperature rise in muscle phantoms by the Electrical Impedance Tomography system during hyperthermia treatment [0.03%]
用电阻抗断层成像系统在热疗过程中监测肌肉体模温度变化的可行性研究
H Woo,Y Kim,A Guy
H Woo
A simulation study of monitoring temperature rises during hyperthermia treatment was conducted on an Electrical Impedance Tomography (EIT) system developed at the University of Washington. A 2,450 MHz microwave generator was used to induce ...
Theoretical analysis of H-Horn annular phased array system for heating deep-seated tumors [0.03%]
H型Horn环形相阵列系统用于深部肿瘤加热的理论研究
D Tianquan,L Zheng,R Wei
D Tianquan
This paper discusses a type of annular phased array system--H-Horn APA. The phase and amplitude control of power deposition patterns for this system are theoretically analyzed at a frequency of 200 MHz. The formulas for calculating E-field ...
Exposure of fertile chicken eggs to microwave radiation (2.45 GHz, CW) during incubation: technique and evaluation [0.03%]
孵化期间鸡胚胎卵受连续波微波辐射(2.45GHz)暴露的技术与评估
L Braithwaite,W Morrison,L Otten et al.
L Braithwaite et al.
A multi-mode cavity constructed of 22-gauge perforated galvanized steel with a horn irradiator was used to expose chicken embryos to microwave (MW) radiation during incubation. The MW exposure system was placed within an environmental chamb...
Alleged health effects of electromagnetic fields: misconceptions in the scientific literature [0.03%]
电磁场的所谓健康影响:科学文献中的误解
J Jauchem
J Jauchem
Occupational or residential exposures to electromagnetic fields or microwaves have been alleged to result in health problems, including leukemia, other cancers, and reproductive mishaps. Several recent articles and editorials in the medical...
Programmable sweep radiometer system as a new tool for non-invasive thermometry [0.03%]
一种新的可编程扫描辐射仪系统作为无创测温工具
M Miyakawa
M Miyakawa
A new microwave radiometer system consisting of a frequency sweep-type radiometer and an ultra wideband antenna has been developed. A computer-controlled radiometer system covers the input frequency range from 0.5 GHz to 8 GHz. It can be us...