首页 文献索引 SCI期刊 AI助手
期刊目录筛选

期刊名:Ieee transactions on nuclear science

缩写:IEEE T NUCL SCI

ISSN:0018-9499

e-ISSN:1558-1578

IF/分区:2.4/Q2

文章目录 更多期刊信息

共收录本刊相关文章索引219条
Clinical Trial Case Reports Meta-Analysis RCT Review Systematic Review
Classical Article Case Reports Clinical Study Clinical Trial Clinical Trial Protocol Comment Comparative Study Editorial Guideline Letter Meta-Analysis Multicenter Study Observational Study Randomized Controlled Trial Review Systematic Review
W J Ashmanskas,B C LeGeyt,F M Newcomer et al. W J Ashmanskas et al.
Waveform sampling is an appealing technique for instruments requiring precision time and pulse-height measurements. Sampling each PMT waveform at oscilloscope-like rates of several gigasamples per second enables one to process PMT signals d...
Jeffrey P Schmall,Junwei Du,Martin S Judenhofer et al. Jeffrey P Schmall et al.
We present an analysis of the signal properties of a position-sensitive solid-state photomultiplier (PS-SSPM) that has an integrated resistive network for position sensing. Attractive features of PS-SSPMs are their large area and ability to...
Sergey Komarov,Tae Yong Song,Heyu Wu et al. Sergey Komarov et al.
In this work we propose a parallel beam approximation for the computation of the detection efficiency of crystals in a PET detector array. In this approximation the detection efficiency of a crystal is estimated using the distance between s...
Mahdi M Kalayeh,Thibault Marin,Jovan G Brankov Mahdi M Kalayeh
In this paper, we present two new numerical observers (NO) based on machine learning for image quality assessment. The proposed NOs aim to predict human observer performance in a cardiac perfusion-defect detection task for single-photon emi...
Srilalan Krishnamoorthy,Benjamin LeGeyt,Matthew E Werner et al. Srilalan Krishnamoorthy et al.
This paper describes the design and performance of a high spatial resolution PET detector with time-of-flight capabilities. With an emphasis on high spatial resolution and sensitivity, we initially evaluated the performance of several 1.5 ...
Jinsong Ouyang,Se Young Chun,Yoann Petibon et al. Jinsong Ouyang et al.
This study was to obtain voxel-wise PET accuracy and precision using tissue-segmentation for attenuation correction. We applied multiple thresholds to the CTs of 23 patients to classify tissues. For six of the 23 patients, MR images were al...
Tracy L Faber,Cesar A Santana,Marina Piccinelli et al. Tracy L Faber et al.
Explicit fusion of perfusion data from Positron Emission Tomography (PET) or Single Photon Emission Computed Tomography (SPECT) with coronary artery anatomy from Computed Tomographic Coronary Angiography (CTA) has been shown to improve the ...
Samrat Dey,Lushon Banks,Shaw-Pin Chen et al. Samrat Dey et al.
Our lab has previously reported on novel board-level readout electronics for an 8×8 silicon photomultiplier (SiPM) array featuring row/column summation technique to reduce the hardware requirements for signal processing. We are taking the ...
Paul Dasari,Karen Johnson,Joyoni Dey et al. Paul Dasari et al.
Respiratory motion of the heart impacts the diagnostic accuracy of myocardial-perfusion emission-imaging studies. Amplitude binning has come to be the method of choice for binning list-mode based acquisitions for correction of respiratory m...
Bing Feng,Michael A King Bing Feng
We developed a unique method for estimating and compensating rigid-body translations and rotations from scatter and-attenuation-compensated projection data in iterative reconstruction when multiple projection angles are acquired at the same...