首页 文献索引 SCI期刊 AI助手
期刊目录筛选

期刊名:Ieee transactions on nuclear science

缩写:IEEE T NUCL SCI

ISSN:0018-9499

e-ISSN:1558-1578

IF/分区:2.4/Q2

文章目录 更多期刊信息

共收录本刊相关文章索引218
Clinical Trial Case Reports Meta-Analysis RCT Review Systematic Review
Classical Article Case Reports Clinical Study Clinical Trial Clinical Trial Protocol Comment Comparative Study Editorial Guideline Letter Meta-Analysis Multicenter Study Observational Study Randomized Controlled Trial Review Systematic Review
J F Christian,M S Squillante,M J Breen et al. J F Christian et al.
This work explores the fabrication and characterization of X-ray imaging devices using a single-crystal TlBr sample (8 mm × 8 mm × 10 mm) and polycrystalline TlBr film (approximately 0.38-mm thick), both bonded to a Libra-1 Complementary ...
Jarek Glodo,Pijush Bhattacharya,Yaroslav Ogorodnik et al. Jarek Glodo et al.
Thallium chloride (TlCl) is a promising material for radiation detection due to its high gamma-ray stopping power and cost-effective manufacturing. In its undoped form, TlCl emits prompt Cherenkov photons, while double doping with Be and Tl...
Akyl Swaby,Kaitlin Hellier,Linxi Shi et al. Akyl Swaby et al.
Amorphous selenium (a-Se) as a direct conversion X-ray photoconductor has many desirable properties in X-ray imaging, due to its high spatial resolution, low dark current, high absorption efficiency, and large area fabrication. We present t...
Joe A Johnson,Glenn E Sjoden,Taylor S Kimball et al. Joe A Johnson et al.
Here we develop and explore hybrid simulation techniques to expedite pre-test analysis of experimental designs for radiation hardness assurance testing efforts. Specifically, we focus on neutron displacement damage (NDD) testing, governed b...
M S Squillante,M J Breen,J F Christian et al. M S Squillante et al.
The detector that converts X-ray intensity into a digitized electronic signal, processed into an image, often limits the performance of modern X-ray imaging systems, whether for medical, research, or industrial applications. Digital radiogr...
Danyal J Turkoglu,H Heather Chen-Mayer Danyal J Turkoglu
A linear fast neutron beam chopper has been deployed at a prompt gamma activation analysis instrument, enabling in-beam activation analysis of short-lived T 1 / 2 > ∼ 10 ms neutron capture products without the need for sample ...
Yixin Li,Xinjie Zeng,Amir H Goldan Yixin Li
Signal multiplexing is necessary to reduce a large number of readout channels in positron emission tomography (PET) scanners to minimize cost and achieve lower power consumption. However, the conventional weighted average energy method cann...
Z Gu,D L Prout,R Taschereau et al. Z Gu et al.
Pulse pileup events degrade the signal-to-noise ratio (SNR) of nuclear medicine data. When such events occur in multiplexed detectors, they cause spatial misposition, energy spectrum distortion and degraded timing resolution, which leads to...
K Pritchard,A Osovizky,J Ziegler et al. K Pritchard et al.
We used Gaussian separation and receiver operating characteristic (ROC) curves to optimize the neutron sensitivity and gamma rejection of an ultra-thin 6LiF:ZnS(Ag)-scintillator-based neutron detector paired with a silicon photomultiplier (...
Xinyi Cheng,Kun Hu,Yiping Shao Xinyi Cheng
We investigated a simple and effective method to extend 1-bit sigma-delta modulation (SDM) circuit based charge-to-digital converter (QDC) to read dual-polarity silicon photomultiplier (SiPM) output signals. With the same QDC circuit but di...