Imaging Results from a Direct Conversion X-ray Detector with TlBr and CMOS Pixel Array [0.03%]
TlBr直接转换X射线探测器的成像性能研究
J F Christian,M S Squillante,M J Breen et al.
J F Christian et al.
This work explores the fabrication and characterization of X-ray imaging devices using a single-crystal TlBr sample (8 mm × 8 mm × 10 mm) and polycrystalline TlBr film (approximately 0.38-mm thick), both bonded to a Libra-1 Complementary ...
Doping schemes in Thallium Chloride to Increase Scintillation Light Yield for Fast Gamma Detection [0.03%]
掺杂提高氯化铊中伽马射线散射光产额的研究
Jarek Glodo,Pijush Bhattacharya,Yaroslav Ogorodnik et al.
Jarek Glodo et al.
Thallium chloride (TlCl) is a promising material for radiation detection due to its high gamma-ray stopping power and cost-effective manufacturing. In its undoped form, TlCl emits prompt Cherenkov photons, while double doping with Be and Tl...
Akyl Swaby,Kaitlin Hellier,Linxi Shi et al.
Akyl Swaby et al.
Amorphous selenium (a-Se) as a direct conversion X-ray photoconductor has many desirable properties in X-ray imaging, due to its high spatial resolution, low dark current, high absorption efficiency, and large area fabrication. We present t...
Use of Different Reactor Physics Models and CADIS Accelerated MCNP to Yield a 1 MeV Silicon Equivalent Flux for Neutron Damage [0.03%]
利用不同的反应堆物理模型和CADIS加速MCNP计算1MeV硅当量中子损伤剂量注量
Joe A Johnson,Glenn E Sjoden,Taylor S Kimball et al.
Joe A Johnson et al.
Here we develop and explore hybrid simulation techniques to expedite pre-test analysis of experimental designs for radiation hardness assurance testing efforts. Specifically, we focus on neutron displacement damage (NDD) testing, governed b...
M S Squillante,M J Breen,J F Christian et al.
M S Squillante et al.
The detector that converts X-ray intensity into a digitized electronic signal, processed into an image, often limits the performance of modern X-ray imaging systems, whether for medical, research, or industrial applications. Digital radiogr...
Danyal J Turkoglu,H Heather Chen-Mayer
Danyal J Turkoglu
A linear fast neutron beam chopper has been deployed at a prompt gamma activation analysis instrument, enabling in-beam activation analysis of short-lived T 1 / 2 > ∼ 10 ms neutron capture products without the need for sample ...
Yixin Li,Xinjie Zeng,Amir H Goldan
Yixin Li
Signal multiplexing is necessary to reduce a large number of readout channels in positron emission tomography (PET) scanners to minimize cost and achieve lower power consumption. However, the conventional weighted average energy method cann...
A New Pulse Pileup Rejection Method Based on Position Shift Identification [0.03%]
基于位置偏移识别的新脉冲堆积拒绝方法
Z Gu,D L Prout,R Taschereau et al.
Z Gu et al.
Pulse pileup events degrade the signal-to-noise ratio (SNR) of nuclear medicine data. When such events occur in multiplexed detectors, they cause spatial misposition, energy spectrum distortion and degraded timing resolution, which leads to...
6LiF:ZnS(Ag) Neutron Detector Performance Optimized Using Waveform Recordings and ROC Curves [0.03%]
基于波形记录和ROC曲线的6LiF:ZnS(Ag)中子探测器性能优化
K Pritchard,A Osovizky,J Ziegler et al.
K Pritchard et al.
We used Gaussian separation and receiver operating characteristic (ROC) curves to optimize the neutron sensitivity and gamma rejection of an ultra-thin 6LiF:ZnS(Ag)-scintillator-based neutron detector paired with a silicon photomultiplier (...
Dual-Polarity SiPM Readout Electronics Based on 1-bit Sigma-Delta Modulatiom Circuit for PET Detector Applications [0.03%]
基于单比特Sigma-Delta调制电路的正负双极SiPM读出电子学应用于PET探测器中
Xinyi Cheng,Kun Hu,Yiping Shao
Xinyi Cheng
We investigated a simple and effective method to extend 1-bit sigma-delta modulation (SDM) circuit based charge-to-digital converter (QDC) to read dual-polarity silicon photomultiplier (SiPM) output signals. With the same QDC circuit but di...