Joe A Johnson,Glenn E Sjoden,Taylor S Kimball et al. Joe A Johnson et al.
Here we develop and explore hybrid simulation techniques to expedite pre-test analysis of experimental designs for radiation hardness assurance testing efforts. Specifically, we focus on neutron displacement damage (NDD) testing, governed b...
M S Squillante,M J Breen,J F Christian et al. M S Squillante et al.
The detector that converts X-ray intensity into a digitized electronic signal, processed into an image, often limits the performance of modern X-ray imaging systems, whether for medical, research, or industrial applications. Digital radiogr...
Danyal J Turkoglu,H Heather Chen-Mayer Danyal J Turkoglu
A linear fast neutron beam chopper has been deployed at a prompt gamma activation analysis instrument, enabling in-beam activation analysis of short-lived T 1 / 2 > ∼ 10 ms neutron capture products without the need for sample ...
Yixin Li,Xinjie Zeng,Amir H Goldan Yixin Li
Signal multiplexing is necessary to reduce a large number of readout channels in positron emission tomography (PET) scanners to minimize cost and achieve lower power consumption. However, the conventional weighted average energy method cann...
Z Gu,D L Prout,R Taschereau et al. Z Gu et al.
Pulse pileup events degrade the signal-to-noise ratio (SNR) of nuclear medicine data. When such events occur in multiplexed detectors, they cause spatial misposition, energy spectrum distortion and degraded timing resolution, which leads to...
K Pritchard,A Osovizky,J Ziegler et al. K Pritchard et al.
We used Gaussian separation and receiver operating characteristic (ROC) curves to optimize the neutron sensitivity and gamma rejection of an ultra-thin 6LiF:ZnS(Ag)-scintillator-based neutron detector paired with a silicon photomultiplier (...
Xinyi Cheng,Kun Hu,Yiping Shao Xinyi Cheng
We investigated a simple and effective method to extend 1-bit sigma-delta modulation (SDM) circuit based charge-to-digital converter (QDC) to read dual-polarity silicon photomultiplier (SiPM) output signals. With the same QDC circuit but di...
Zhi Deng,Allan K Lan,Xishan Sun et al. Zhi Deng et al.
An eight-channel readout ASIC has been developed for reading output signals from solid-state photomultipliers for positron emission tomography applications. This ASIC converts both the signal charge and occurring time to digital timing puls...
Joyoni Dey Joyoni Dey
SPECT is primarily used in the clinic for cardiac myocardial perfusion imaging. However, for SPECT, sensitivity is impaired due to the need for collimation. System resolution FWHM is poor as well (~ 1 cm). In this work the resolution of a c...
E G Stassinopoulos,J L Barth,C A Stauffer E G Stassinopoulos