Endocarditis and other indications for open-heart surgery after transcatheter aortic valve implantation [0.03%]
经导管主动脉瓣植入后的感染性心内膜炎和其他开胸手术指标
Torbjörn Ivert,Aninda Omar,Andreas Rück et al.
Torbjörn Ivert et al.
This retrospective observational single-centre analysis included 31 patients who underwent transcatheter aortic valve implantation (TAVI) between 2016 and 2024 and subsequent open-heart surgery between 2019 and 2024. They were admitted from...
Mid-term outcomes after aortic valve replacement in patients under 70: A comparative study of INSPIRIS RESILIA versus PERIMOUNT MAGNA EASE bioprostheses [0.03%]
主动脉瓣置换术中INSPIRIS RESILIA与PERIMOUNT MAGNA EASE生物瓣膜在小于70岁患者中的中期效果比较研究
Gabriel Saiydoun,Elie Nassar,Saadé Saadé et al.
Gabriel Saiydoun et al.
Objectives: INSPIRIS RESILIA, launched in 2017, is a bioprosthetic aortic valve developed to improve durability and facilitate future valve-in-valve procedures. Despite its advanced design, many surgeons continue to use t...
Local recurrence after sublobar resection for primary lung cancer: Does the type of stapling device matter? [0.03%]
肺癌亚肺叶切除术后吻合器类型影响局部复发吗?
Go Kamimura,Masaya Aoki,Satomi Imamura et al.
Go Kamimura et al.
Objectives: Two major types of stapling devices exist: those with disposable built-in knives and those with non-disposable built-in knives. This study investigated whether the stapler type influences the incidence of loca...
Thoracoscopic pneumonectomy for massive haemoptysis secondary to chronic pulmonary vein stenosis post-atrial fibrillation ablation [0.03%]
经胸腔镜肺叶切除术治疗房颤射频消融术后慢性肺静脉狭窄大咯血
Fumie Osuga,Kentaro Minegishi,Shunsuke Endo et al.
Fumie Osuga et al.
Pulmonary vein (PV) stenosis is a rare but serious complication after transcatheter ablation for atrial fibrillation, potentially leading to massive haemoptysis. We present a case of severe PV stenosis resulting in haemoptysis. A 57-year-ol...
Superior safety and surgical efficiency by automated vacuum-assisted venous drainage over conventional, survey based evaluation [0.03%]
自动负压静脉引流优于传统的常规调查评估,在安全和外科手术效率方面更胜一筹
Youssef El Dsouki,Ignazio Condello
Youssef El Dsouki
The evolution of cardiopulmonary bypass (CPB) techniques has been significantly enhanced by the integration of Vacuum-Assisted Venous Drainage (VAVD). VAVD improves venous return in minimally invasive, paediatric, and complex cardiac surger...
Outcomes following extended thoracic endovascular aortic repair for type b aortic dissection from the global registry for endovascular aortic treatment [0.03%]
全球主动脉腔内治疗注册中心B型主动脉夹层远端延伸胸主动脉腔内修复术后结果分析
Sara Allievi,Tim J Mandigers,Fred A Weaver et al.
Sara Allievi et al.
Objectives: This study evaluated the short- to longer-term safety and efficacy of extended thoracic endovascular aortic repair for type B aortic dissection. ...
Single-port robotic-assisted approach in thoracic surgery: A prospective real-world study [0.03%]
单孔机器人辅助胸部手术的前瞻性研究
Chengqiang Li,Xiang Chen,Xipeng Wang et al.
Chengqiang Li et al.
Objectives: Robotic systems have enhanced thoracic surgery through three-dimensional visualization, maneuverability, and tremor filtration. This study evaluated the effectiveness and safety of the da Vinci single-port sur...
Total arch with hybrid frozen elephant trunk versus branched stented anastomosis frozen elephant trunk repair [0.03%]
一次性完全主动脉弓置换术杂交冰象干技术与分支覆膜支架吻合冰象干技术的对比研究
Aakash Shah,Joshua Leibowitz,Jeffrey Lu et al.
Aakash Shah et al.
Objectives: This study aims to evaluate the short-term outcomes of total arch replacement using two techniques: the branched stented anastomosis frozen elephant trunk repair (B-SAFER) under moderate hypothermia (25-28 °C...
National outcomes of surgical ablation for atrial fibrillation at the time of mitral surgery [0.03%]
二尖瓣手术同期房颤外科消融的全国性结果分析
Aminah Sallam,Derrick Y Tam,Qiudong Chen et al.
Aminah Sallam et al.
Objectives: Current guidelines recommend concomitant surgical ablation at the time of mitral surgery for patients with atrial fibrillation, however there is a paucity of data on long-term outcomes in this population. We s...
The outlet orifice diameter of surgical bioprosthetic aortic stented valves is predominantly much smaller than the inlet orifice diameter [0.03%]
手术生物主动脉瓣的出口直径明显小于入口直径
Astrid Gerritje Maria Van Boxtel,Tjark Ebels
Astrid Gerritje Maria Van Boxtel
Objectives: Surgical prosthetic valve labelling is misleading, as labelled diameters (LD) are currently always larger than inlet orifice diameter (IOD), while the outlet orifice (OOD) is unknown. The IOD, OOD and height o...