Total body irradiation in Australia and New Zealand: results of a practice survey [0.03%]
澳大利亚和新西兰全身照射的临床实践调查结果
Lotte S Fog,Andrew Wirth,Michael MacManus et al.
Lotte S Fog et al.
Total body irradiation (TBI) is an important treatment modality for the preparation of patients for bone marrow transplants. It is technically challenging and the actual delivery may vary from clinic to clinic. Knowledge of the pattern of p...
Path planning of the viscoelastic micro biological particle to minimize path length and particle's deformation using genetic algorithm [0.03%]
基于遗传算法的微生物粒子路径规划以实现行程最短和粒子变形最小化
M H Korayem,S Shahali,Z Rastegar et al.
M H Korayem et al.
Manipulation of biological particles including pulling, and holding-and-indenting them, using the atomic force microscope (AFM) has attracted enormous interests. High deformability and vulnerability of biological particles, especially cells...
James Rijken,Scott Crowe,Jamie Trapp et al.
James Rijken et al.
Radiation therapy of the spine, as recourse for spinal tumours, is an effective method of achieving pain reduction and local control. Hypofractionated techniques like stereotactic body radiation therapy and especially stereotactic radiosurg...
Truncated inception net: COVID-19 outbreak screening using chest X-rays [0.03%]
截断式 inception 网络:使用胸部 X 光片筛查新冠肺炎疫情
Dipayan Das,K C Santosh,Umapada Pal
Dipayan Das
Since December 2019, the Coronavirus Disease (COVID-19) pandemic has caused world-wide turmoil in a short period of time, and the infection, caused by SARS-CoV-2, is spreading rapidly. AI-driven tools are used to identify Coronavirus outbre...
Automated segmentation of optic disc using statistical region merging and morphological operations [0.03%]
基于统计区域聚合和数学形态学操作的视盘自动分割算法
K S Nija,C P Anupama,Varun P Gopi et al.
K S Nija et al.
Accurate Optic Disc (OD) segmentation is vital in designing systems that aid the diagnosis and evaluation of early phases of retinal diseases. However, in many images, the OD boundary is ambiguous, which makes the automated OD segmentation ...
An assessment of the ExacTrac intrafraction imaging capabilities for flattening filter free prostate stereotactic body radiotherapy [0.03%]
评估ExacTrac无平坦过滤器的前列腺立体定向体放射治疗期间的实时图像引导能力
James Rijken,Mark Sidhom
James Rijken
The uncertainties associated with image matching using the ExacTrac® system (BrainLab, Munich, Germany) have been the subject of investigation in the literature for extra-cranial sites. However, the uncertainties involved in the use of Exa...
Analysing the effect of wearable lift-assist vest in squat lifting task using back muscle EMG data and musculoskeletal model [0.03%]
基于背部肌肉表面EMG和生物力学模型分析助力背心对弯腰搬起重物的影响研究
Gholamreza Ataei,Rasoul Abedi,Yousef Mohammadi et al.
Gholamreza Ataei et al.
The most common disorders of the musculoskeletal system are low back disorders. They cause significant direct and indirect costs to different societies especially in lifting occupations. To reduce the risk of low back disorders, mechanical ...
Recognition of cardiac abnormalities from synchronized ECG and PCG signals [0.03%]
基于同步ECG和PCG信号的心脏异常识别
Fatima Chakir,Abdelilah Jilbab,Chafik Nacir et al.
Fatima Chakir et al.
Phonocardiogram signals (PCG) and electrocardiogram signals (PCG) have been used separately for decades to diagnose heart abnormalities. Combining these two synchronous signals is expected to enhance the diagnosis for better medical managem...
The effect of megavoltage field size on intrafraction cone-beam CT image quality [0.03%]
兆伏级野尺寸对锥形束CT图像质量的影像研究
Georgia Friend,Patrick OConnor,Paul Charles
Georgia Friend
To investigate the effects of scatter from a megavoltage treatment beam on intrafraction cone beam CT (CBCT) image quality. The effects of treatment beam field size and phantom geometry were investigated as well as the clinical success of I...
Quasi-simultaneous 3D printing of muscle-, lung- and bone-equivalent media: a proof-of-concept study [0.03%]
类肌肉、类肺和类骨介质的准同步3D打印研究概念性试验
T Kairn,M Zahrani,N Cassim et al.
T Kairn et al.
3D printing is a promising solution for the production of bespoke phantoms and phantom components, for radiotherapy dosimetry and quality assurance (QA) purposes. This proof-of-concept study investigated the use of a dual-head printer to de...