Benefits of daily online plan adaptation with reduced margins in neoadjuvant chemoradiotherapy for esophageal cancer [0.03%]
新辅助化学放射治疗中每日在线计划调整和减少边缘量的优势:一项针对食管癌的前瞻性研究
Leigh A P Bruijs,Thomas Weststrate,Karin N Goudschaal et al.
Leigh A P Bruijs et al.
Background and purpose: Image-guided radiotherapy (IGRT) for esophageal cancer requires large planning target volume (PTV) margins to account for interfraction variations, increasing radiation-associated side-effects. Con...
AID-RT: Standardising Artificial Intelligence Documentation in RadioTherapy with a domain-specific model card [0.03%]
基于领域专用模型卡片的放射治疗人工智能文档标准化(AID-RT)
Ana M Barragán-Montero,Margerie Huet-Dastarac,Silvia M Herranz-Hernández et al.
Ana M Barragán-Montero et al.
Background and purpose: Insufficient documentation of artificial intelligence (AI) models remains a widespread issue, which hampers reproducibility in research environments and safe integration in clinical departments. Ou...
Internal target volume reproducibility and dose coverage for lung stereotactic body radiotherapy using spine-based positioning and tracking [0.03%]
基于脊柱定位和跟踪的立体定向体部放疗的靶区体积重复性和剂量覆盖率
Thomas Opsommer,Mylène Messéant,Florence Le Tinier et al.
Thomas Opsommer et al.
Free-breathing spine-based positioning/tracking in lung stereotactic body radiotherapy is required when direct tumor positioning is not possible. Respiratory baseline, motion and target position reproducibility interact and remain uncertain...
Impact of intra- and interfractional motion on the dose distribution and urinary adverse events for magnetic resonance-guided prostate cancer radiotherapy [0.03%]
前列腺癌磁共振引导放射治疗的内运动和间质运动对剂量分布及泌尿不良事件的影响研究
Shu Xing,Sarah Burleson,Xiao Tan et al.
Shu Xing et al.
Purpose: To evaluate the impact of intra- and interfractional motion on dose distribution and clinical outcome in prostate magnetic resonance (MR)-guided adaptive radiotherapy. ...
A meta-analysis of dose-volume parameters and treatment efficiency comparing O-ring and C-arm accelerator systems for craniospinal irradiations [0.03%]
O-臂加速器系统与环形加速器系统全中枢神经系统照射剂量参数及疗效的meta分析研究
Yaotao Li,Guozi Yang,Liangliang Lei et al.
Yaotao Li et al.
Background and purpose: Craniospinal irradiation (CSI) is a critical treatment modality for central nervous system (CNS) tumors. This study aimed to compare the dose-volume parameters and treatment efficiency between O-ri...
An efficient automated approach for accumulated dose estimation in prostate cancer radiotherapy [0.03%]
前列腺癌放射治疗的累积剂量估计的有效自动化方法
Maximilian Grohmann,David Krug,Andrea Baehr et al.
Maximilian Grohmann et al.
Background and purpose: Anatomical variations during prostate radiotherapy can cause discrepancies between planned and delivered doses, which may become more pronounced in (ultra-)hypofractionated regimens. However, a sta...
Treatment planning for lung cancer reirradiation accounting for previously delivered dose [0.03%]
考虑先前接受的剂量的肺癌再照射治疗计划
David P Walton,Christopher Thompson,Dominic Lowe et al.
David P Walton et al.
Reirradiation is increasingly used for recurrent and new primary cancers, but dedicated planning tools are limited. We integrated deformable image registration and radiobiologically consistent dose accumulation into plan optimisation to imp...
A deep learning approach for predicting linear accelerator output settings in automated radiotherapy planning of oligometastatic cancer [0.03%]
用于寡转移癌症自动化放射治疗计划的直线加速器输出设置预测的深度学习方法
Mathieu Gaudreault,Lachlan McIntosh,Katrina Woodford et al.
Mathieu Gaudreault et al.
Background and purpose: The monitor units (MU) per control point (CP) control the necessary fine-tuned ablative dose for hypofractionated radiotherapy of oligometastatic cancer. We aimed to introduce strategies maximising...
Reduction of organ of interest dose in proton therapy for oesophageal cancer through optimized setup robustness settings and online adaptation [0.03%]
通过优化设置鲁棒性和在线适应以减少食管癌质子治疗的感兴趣器官剂量
Eva van Weerd,Anne Lisa Wolf,Steven J M Habraken et al.
Eva van Weerd et al.
Background and purpose: Oesophageal radiotherapy may cause side effects due to high organs of interest (OOIs) doses. While proton therapy (PT) reduces OOI dose compared to photon therapy, setup robustness settings used ma...
Multicentre dosimetry audit in the European randomized phase III study of neoadjuvant chemoradiotherapy using proton versus photon radiotherapy in locally advanced oesophageal cancer [0.03%]
欧洲新辅助放化疗Ⅲ期临床研究中局部晚期食道癌采用质子与光子放射治疗的多中心剂量校准审核
Mai L Ehmsen,Camilla S Byskov,Hanna R Mortensen et al.
Mai L Ehmsen et al.
This study presents the results of a multicentre external dosimetry audit conducted as part of the PROTECT trial, involving nine European radiotherapy centres delivering proton and photon treatments. A dosimetry equipment vendor performed b...