S Rasoul Zakavi
S Rasoul Zakavi
Subcutaneous Extravasation of Sr-89: Usefulness of Bremsstrahlung Imaging in Confirming Sr-89 Extravasation and in the Decision Making for the Choice of Treatment Strategies for Local Radiation Injuries Caused by Sr-89 Extravasation [0.03%]
Sr-89外渗的皮下组织摄取:关于Bremsstrahlung显像对确认Sr-89外渗及由Sr-89外渗造成局部放射损伤治疗决策的价值研究
Joji Kawabe,Shigeaki Higashiyama,Kohei Kotani et al.
Joji Kawabe et al.
A male patient in his 20s presented at our clinic with pain caused by bone metastases of the primitive neuroectodermal tumor, and Sr-89 was administrated to palliate the pain. After receiving the injection, the patient complained of a sligh...
Uzma Afzal,Rasha Mater Al-Shammari,Qaisar H Siraj et al.
Uzma Afzal et al.
Duplication anomalies are quite common with ureteral duplication anomalies being the most frequent. Despite the relatively frequent incidence of a horseshoe kidney and duplication anomalies in any individual patient, the combination of hors...
Assessment of epidermal growth factor receptor status in glioblastomas [0.03%]
评估表皮生长因子受体在胶质母细胞瘤中的状态
Hui-Jun Zhu,Mikako Ogawa,Yasuhiro Magata et al.
Hui-Jun Zhu et al.
Objectives: Our previous study showed that a newly designed tracer radioiodinated 6-(3-morpholinopropoxy)-7-ethoxy-4-(3'-iodophenoxy)quinazoline ([(125)I]PYK) is promising for the evaluation of the epidermal growth factor...
Impact of PET - CT motion correction in minimizing the gross tumor volume in non-small cell lung cancer [0.03%]
利用pet-ct运动校正在非小细胞肺癌中缩小原发肿瘤靶区勾画范围的影响分析
Michael A Masoomi,Anne H McLean,Yassine Bouchareb et al.
Michael A Masoomi et al.
Objectives: To investigate the impact of respiratory motion on localization, and quantification of lung lesions for the Gross Tumor Volume utilizing a fully automated Auto3Dreg program and dynamic NURBS-based cardiac-tors...
Differential impact of multi-focus fan beam collimation with L-mode and conventional systems on the accuracy of myocardial perfusion imaging: Quantitative evaluation using phantoms [0.03%]
多焦点扇束准直器L模式和常规方式对心肌灌注显像准确性影响的差异:利用模型的定量评估研究
Hideo Onishi,Norikazu Matsutomo,Yoshiharu Kangai et al.
Hideo Onishi et al.
Objectives: A novel IQ-SPECT™ method has become widely used in clinical studies. The present study compares the quality of myocardial perfusion images (MPI) acquired using the IQ-SPECT™ (IQ-mode), conventional (180° ap...
Is (99m)Tc-MIBI scintigraphy a predictor of response to pre-operative neoadjuvant chemotherapy in Osteosarcoma? [0.03%]
99mTc-MIBI显像可否预测骨肉瘤新辅助化疗的疗效?
Mohammad Gharehdaghi,Vahid Reza Dabbagh Kakhki,Alireza Khooei et al.
Mohammad Gharehdaghi et al.
Objectives: Multidrug resistance (MDR), which may be due to the over expression of P-glycoprotein (Pgp) and/or MRP, is a major problem in neoadjuvant chemotherapy of osteosarcoma. The aim of this study was to investigate ...
Translation of Methodology Used In Human Myocardial Imaging to a Sheep Model of Acute Myocardial Infarction [0.03%]
人的心肌影像方法学向急性心梗羊模型的转化研究
Elizabeth A Bailey,Dale L Bailey,Stephen Hunyor et al.
Elizabeth A Bailey et al.
Introduction: Pre-clinical investigation of stem cells for repairing damaged myocardium predominantly uses rodents, however large animals have cardiac circulation closely resembling the human heart. The aim of this study ...
(99m)Tc-MIBI Washout Rate to Evaluate the Effects of Steroid Therapy in Cardiac Sarcoidosis [0.03%]
用(99m)Tc-MIBI洗脱率评估皮质类固醇治疗卡氏肉瘤的效果
Masayoshi Sarai,Sadako Motoyama,Yasuchika Kato et al.
Masayoshi Sarai et al.
Objective: We sought to determine the usefulness of the (99m)Tc-MIBI (MIBI) washout rate for the evaluation of steroid therapy in cardiac sarcoidosis (CS). ...
Durr-E-Sabih
Durr-E-Sabih