Increased dosage of propofol in anesthesia induction cannot control the patient's responses to insertion of a laryngeal mask airway [0.03%]
增加丙泊酚麻醉诱导剂量不能控制声门上喉面罩置入反应
Masahiro Kanazawa,Masahiko Nitta,Tomohiko Murata et al.
Masahiro Kanazawa et al.
An increased dosage of propofol is frequently administered to reduce responses to insertion of the laryngeal mask airway (LMA). However, its clinical effect remains unknown. We investigated whether an increased dosage of propofol reduces re...
A newly developed assessment scale for attentional disturbance based on behavioral problems: Behavioral Assessment of Attentional Disturbance (BAAD) [0.03%]
基于行为问题的新注意力障碍评估量表:行为注意障碍评估(BAAD)
Minoru Toyokura,Kayo Yamashita,Tomomi Hayashi et al.
Minoru Toyokura et al.
Attentional disturbance following brain damage has been commonly evaluated by having the patients perform neuropsychological tasks. In rehabilitation settings, however, the primary concern is not task performance, but functional real-world ...
Detection of individual over-smoking using conventional laboratory tests [0.03%]
常规实验室检查在个体过度吸烟检测中的应用分析
Yoko Komaki,Hiroyuki Furuya,Reiichi Higashiyama et al.
Yoko Komaki et al.
Objective: The present study was designed to find useful markers for detecting the severity of smoking effects on the human body from conventional laboratory tests used in community health check-ups. ...
Less-invasive method for microsphere delivery to coronary circulation and evaluation of myocardial ischemic change in small animals [0.03%]
一种用于输送微球至冠脉系统的微创方法及对小动物心肌缺血改变的评估方法
Yoshinori Sugio,Etsuro Tanaka,Hidezo Mori et al.
Yoshinori Sugio et al.
We developed a less-invasive method for semi-selective administration of drugs into coronary arteries in small animals. With this method, we created microvascular myocardial ischemia in rabbits by microsphere injection. A 4F catheter was in...
Yasuhisa Oida,Yasuo Ohtani,Shoichi Dowaki et al.
Yasuhisa Oida et al.
Hepatocellular carcinoma rarely metastasizes to the orbit. We report on a 72-year-old man with a past history of resection for hepatocellular carcinoma and recurrent HCC, who presented with diplopia and left painful proptosis. Head scans re...
Estimating input original waveform from catheter-manometer system output waveform--an experimental study with pulmonary artery catheter [0.03%]
导管压力计系统的输出波形估计输入原始波形的实验研究-肺动脉漂浮导管系统
Satoru Saito,Masato Shimada,Yoshio Kinefuchi et al.
Satoru Saito et al.
The present study was performed to investigate the precision of and problems in arithmetic operations for synthesis/estimation of the input waveform from the output waveform of a pulmonary artery catheter (PAC) manometer system, by imposing...