Design and manufacture of a novel system to simulate the biomechanics of basic and pitching shoulder motion [0.03%]
一种模拟基本肩关节运动和投掷肩关节运动生物力学的新系统的研制
V Entezari,B L Trechsel,W A Dow et al.
V Entezari et al.
Objectives: Cadaveric models of the shoulder evaluate discrete motion segments using the glenohumeral joint in isolation over a defined trajectory. The aim of this study was to design, manufacture and validate a robotic s...
Minimal clinically important differences in health-related quality of life after total hip or knee replacement: A systematic review [0.03%]
人工髋关节或膝关节置换术后与健康相关生活质量和最小临床重要差值相关的系统评价
J C Keurentjes,F R Van Tol,M Fiocco et al.
J C Keurentjes et al.
Objectives: We aimed first to summarise minimal clinically important differences (MCIDs) after total hip (THR) or knee replacement (TKR) in health-related quality of life (HRQoL), measured using the Short-Form 36 (SF-36)....
M A Ritter,K E Davis,J B Meding et al.
M A Ritter et al.
Objectives: The purpose of this study was to examine the effect of posterior cruciate ligament (PCL) retention, PCL recession, and PCL excision during cruciate-retaining total knee replacement. ...
D J Langton,R Sidaginamale,J K Lord et al.
D J Langton et al.
Objectives: An ongoing prospective study to investigate failing metal-on-metal hip prostheses was commenced at our centre in 2008. We report on the results of the analysis of the first consecutive 126 failed mated total h...
Validity of synthetic bone as a substitute for osteoporotic cadaveric femoral heads in mechanical testing: A biomechanical study [0.03%]
合成骨作为替代尸骨股骨头在机械测试中的有效性:一项生物力学研究
F ONeill,F Condon,T McGloughlin et al.
F ONeill et al.
Introduction: The objective of this study was to determine if a synthetic bone substitute would provide results similar to bone from osteoporotic femoral heads during in vitro testing with orthopaedic implants. If the syn...
In vivo evaluation of edge-loading in metal-on-metal hip resurfacing patients with pseudotumours [0.03%]
体内评估金属对金属髋关节置换假体边缘效应与假体周围囊性变的关系
Y-M Kwon,S J Mellon,P Monk et al.
Y-M Kwon et al.
Objectives: Pseudotumours (abnormal peri-prosthetic soft-tissue reactions) following metal-on-metal hip resurfacing arthroplasty (MoMHRA) have been associated with elevated metal ion levels, suggesting that excessive wear...
S L Franklin,C Jayadev,R Poulsen et al.
S L Franklin et al.
Objectives: Surgical marking during tendon surgery is often used for technical and teaching purposes. This study investigates the effect of a gentian violet ink marker pen, a common surgical marker, on the viability of th...
Assisted closure of fasciotomy wounds: A descriptive series and caution in patients with vascular injury [0.03%]
血管损伤患者的筋膜切开伤口辅助闭合:一系列描述性病例及注意事项
J R Fowler,M T Kleiner,R Das et al.
J R Fowler et al.
Introduction: Negative pressure wound therapy (NPWT) and vessel loop assisted closure are two common methods used to assist with the closure of fasciotomy wounds. This retrospective review compares these two methods using...
Microseparation, fluid pressure and flow in failures of metal-on-metal hip resurfacing arthroplasties [0.03%]
金属对金属髋关节置换术失败的微分离、流体压力和流动分析
B M Wroblewski,P D Siney,P A Fleming
B M Wroblewski
Objectives: Metal-on-metal (MoM) hip resurfacing was introduced into clinical practice because it was perceived to be a better alternative to conventional total hip replacement for young and active patients. However, an i...
B Sowman,R Radic,M Kuster et al.
B Sowman et al.
Objectives: Overlap between the distal tibia and fibula has always been quoted to be positive. If the value is not positive then an injury to the syndesmosis is thought to exist. Our null hypothesis is that it is a normal...