For the management of mobile tumors, respiratory gating is the ideal option, both during imaging and during therapy. The major advantage of respiratory gating during imaging is that it is possible to create a single artifact-free CT data-se...
Applying graphics processor units to Monte Carlo dose calculation in radiation therapy [0.03%]
基于图形处理器的放射治疗蒙特卡罗剂量计算研究
M Bakhtiari,H Malhotra,M D Jones et al.
M Bakhtiari et al.
We investigate the potential in using of using a graphics processor unit (GPU) for Monte-Carlo (MC)-based radiation dose calculations. The percent depth dose (PDD) of photons in a medium with known absorption and scattering coefficients is ...
Dosimetric analysis and comparison of IMRT and HDR brachytherapy in treatment of localized prostate cancer [0.03%]
调强放疗和高剂量率组织间近距离治疗局灶性前列腺癌的剂量分析及比较研究
V Murali,P G G Kurup,P Mahadev et al.
V Murali et al.
Radical radiotherapy is one of the options for the management of prostate cancer. In external beam therapy, 3D conformal radiotherapy (3DCRT) and intensity modulated radiotherapy (IMRT) are the options for delivery of increased radiation do...
Performance evaluation of an algorithm for fast optimization of beam weights in anatomy-based intensity modulated radiotherapy [0.03%]
基于解剖结构的强度调控放射治疗中快速优化束流权重算法的性能评估
Vaitheeswaran Ranganathan,V K Sathiya Narayanan,Janhavi R Bhangle et al.
Vaitheeswaran Ranganathan et al.
This study aims to evaluate the performance of a new algorithm for optimization of beam weights in anatomy-based intensity modulated radiotherapy (IMRT). The algorithm uses a numerical technique called Gaussian-Elimination that derives the ...
Long term response stability of a well-type ionization chamber used in calibration of high dose rate brachytherapy sources [0.03%]
临床高剂量率后装放射源校准用井型电离室长期响应稳定性研究
S Vandana,S D Sharma
S Vandana
Well-type ionization chamber is often used to measure strength of brachytherapy sources. This study aims to check long term response stability of High Dose Rate (HDR)-1000 Plus well-type ionization chamber in terms of reference air kerma ra...
Suitability of point kernel dose calculation techniques in brachytherapy treatment planning [0.03%]
点核剂量计算在后装治疗计划设计中的应用研究
Thilagam Lakshminarayanan,K V Subbaiah,K Thayalan et al.
Thilagam Lakshminarayanan et al.
Brachytherapy treatment planning system (TPS) is necessary to estimate the dose to target volume and organ at risk (OAR). TPS is always recommended to account for the effect of tissue, applicator and shielding material heterogeneities exist...
Dose distribution near thin titanium plate for skull fixation irradiated by a 4-MV photon beam [0.03%]
4MV光子束照射颅骨固定用薄钛板附近的剂量分布
Tomohiro Shimozato,Keisuke Yasui,Ryota Kawanami et al.
Tomohiro Shimozato et al.
To investigate the effects of scattered radiation when a thin titanium plate (thickness, 0.05 cm) used for skull fixation in cerebral nerve surgery is irradiated by a 4-MV photon beam. We investigated the dose distribution of radiation insi...
Dosimetry of interface region near closed air cavities for Co-60, 6 MV and 15 MV photon beams using Monte Carlo simulations [0.03%]
基于蒙特卡罗模拟的钴-60、6MV和15MV光子束空气腔闭合区域附近界面区剂量学研究
Chandra P Joshi,Johnson Darko,P B Vidyasagar et al.
Chandra P Joshi et al.
Underdosing of treatment targets can occur in radiation therapy due to electronic disequilibrium around air-tissue interfaces when tumors are situated near natural air cavities. These effects have been shown to increase with the beam energy...
Analytical correction of an extension of the "MU Fraction Approximation" for Varian enhanced dynamic wedges [0.03%]
瓦里安动态楔形板修正的“MU分数近似”方法的扩展分析校正
Michael S Gossman,Subhash C Sharma
Michael S Gossman
The most common method to determine enhanced dynamic wedge factors begins with the use of segmented treatment tables. These segmental dose delivery values set as a function of upper jaw position are the backbone of a calculation process coi...
Gopalakrishna Kurup
Gopalakrishna Kurup