A S Pradhan
A S Pradhan
R I Obed,H T Lateef,A K Ademola
R I Obed
CR-39 tracketch detectors were used for the measurement of (222)Rn concentration in 24 offices in Nigeria's oldest university campus in order to estimate the effective dose to the occupants from (222)Rn and its progeny. The dosimetric measu...
Spatial distribution of gamma radiation levels in surface soils from Jaduguda uranium mineralization zone, Jharkhand, India, using γ-ray spectrometry, and determination of outdoor dose to the population [0.03%]
印度贾坎德州贾杜古达铀矿化区地表土壤伽马辐射水平的分布(使用γ能谱仪)及户外剂量的测定
Mandakini Maharana,Narayani Krishnan,D Sengupta
Mandakini Maharana
The concentrations of natural radionuclides in surface soil samples around selected villages of Jaduguda were investigated and compared with the radioactivity level in the region. Concentrations of (238)U, (232)Th, and (40)K were determined...
Radiological safety status and quality assurance audit of medical X-ray diagnostic installations in India [0.03%]
印度医疗X射线诊断装置的放射安全状况和质量保证审核
A U Sonawane,Meghraj Singh,J V K Sunil Kumar et al.
A U Sonawane et al.
We conducted a radiological safety and quality assurance (QA) audit of 118 medical X-ray diagnostic machines installed in 45 major hospitals in India. The main objective of the audit was to verify compliance with the regulatory requirements...
Automatic and manual image fusion of In-pentetreotide SPECT and diagnostic CT in neuroendocrine tumor imaging - An evaluation [0.03%]
内窥恩特肽SPECT与诊断CT的图像融合在神经内分泌肿瘤中的应用价值评估研究
Elisabeth Hedlund,Jan-Erik Karlsson,Sven-Åke Starck
Elisabeth Hedlund
In the clinical diagnosis of neuroendocrine tumors (NET), the results of examinations, such as high-resolution computed tomography (CT) and single photon computerized tomography (SPECT), have conventionally been interpreted separately. The ...
Experimental determination of the weighting factor for the energy window subtraction-based downscatter correction for I-123 in brain SPECT studies [0.03%]
实验确定能量窗口减影法用于脑部SPECT显像中碘-123下散射矫正的加权因素
Robin de Nijs,Søren Holm,Gerda Thomsen et al.
Robin de Nijs et al.
Correction for downscatter in I-123 SPECT can be performed by the subtraction of a secondary energy window from the main window, as in the triple-energy window method. This is potentially noise sensitive. For studies with limited amount of ...
Electron beam characteristics at extended source-to-surface distances for irregular cut-outs [0.03%]
扩大源皮距条件下不规则切割野的电子束特性研究
T Arunkumar,Sanjay S Supe,M Ravikumar et al.
T Arunkumar et al.
Electron beam therapy is widely used in the management of cancers. The rapid dose fall-off and the short range of an electron beam enable the treatment of lesions close to the surface, while sparing the underlying tissues. In an extended so...
Effect of various physical parameters on surface and build-up dose for 15-MV X-rays [0.03%]
各种物理参数对15MV X射线表层剂量和累积剂量的影响
Girigesh Yadav,R S Yadav,Alok Kumar
Girigesh Yadav
The purpose of this study was to find out the effect of various physical parameters on the skin and build-up doses of 15-MV photon beams. The effects of field dimensions, acrylic shadow tray, focus to-skin distance (FSD) on surface and buil...
Dose-volume histogram quality assurance for linac-based treatment planning systems [0.03%]
基于直线加速器的治疗计划系统的剂量体积直方图质量保证
Michael S Gossman,Morris I Bank
Michael S Gossman
Dose-volume histograms provide key information to radiation oncologists when they assess the adequacy of a patient treatment plan in radiation therapy. It is important therefore that all clinically relevant data be accurate. In this article...
Implementation and validation of a commercial portal dosimetry software for intensity-modulated radiation therapy pre-treatment verification [0.03%]
商业 portals 验证强度调控放射治疗术前剂量的实施与验证
C Varatharaj,Eugenia Moretti,M Ravikumar et al.
C Varatharaj et al.
Electronic portal imaging devices (EPIDs) are extensively used for obtaining dosimetric information of pre-treatment field verification and in-vivo dosimetry for intensity-modulated radiotherapy (IMRT). In the present study, we have impleme...