首页 文献索引 SCI期刊 AI助手
期刊目录筛选

期刊名:Journal of medical physics

缩写:

ISSN:0971-6203

e-ISSN:1998-3913

IF/分区:1.1/Q4

文章目录 更多期刊信息

共收录本刊相关文章索引173条
Clinical Trial Case Reports Meta-Analysis RCT Review Systematic Review
Classical Article Case Reports Clinical Study Clinical Trial Clinical Trial Protocol Comment Comparative Study Editorial Guideline Letter Meta-Analysis Multicenter Study Observational Study Randomized Controlled Trial Review Systematic Review
Shokouhozaman Soleymanifard,Mohammad T Toossi Bahreyni Shokouhozaman Soleymanifard
Radiation-induced bystander effect refers to radiation responses which occur in non-irradiated cells. The purpose of this study was to compare the level of bystander effect in a couple of tumor and normal cell lines (QU-DB and MRC5). To ind...
Christopher E Neilson,Slav Yartsev Christopher E Neilson
Helical tomotherapy's ability to provide daily megavoltage (MV) computed tomography (CT) images for patient set-up verification allows for the creation of adapted plans. As plans become more complex by introducing sharper dose gradients in ...
H Sudahar,P G G Kurup,V Murali et al. H Sudahar et al.
As the α/β value of prostate is very small and lower than the surrounding critical organs, hypofractionated radiotherapy became a vital mode of treatment of prostate cancer. Cyberknife (Accuray Inc., Sunnyvale, CA, USA) treatment for loca...
Ron S Sloboda,N Usmani,T T Monajemi et al. Ron S Sloboda et al.
This article summarizes current knowledge concerning the characterization of prostatic edema and intra-prostatic seed movement as these relate to dosimetry of permanent prostate implants, and reports the initial application to clinical data...
Pamela Myers,Sotirios Stathakis,Alonso N Gutiérrez et al. Pamela Myers et al.
For routine quality assurance of helical tomotherapy plans, an alternative method, as opposed to the TomoTherapy suggested cylindrical solid water phantom with film and ionization chamber, is proposed using the PTW Seven29 2D-ARRAY inserted...
Christopher H Green Christopher H Green
Nuclear Medicine developed when it was realised that a radioisotopic substitution of Iodine-131 for the stable Iodine-127 would follow the same metabolic pathway in the body enabling the thyroid to be imaged and the thyroid uptake measured....
Shaban Harb,Abd El-Hadi El-Kamel,Abd El-Bast Abbady et al. Shaban Harb et al.
The level of natural radioactivity in rocks and soil of 32 samples collected from locations at North Sana'a in Yemen was measured. Concentrations of radionuclides in rocks and soils samples were determined by gamma-ray spectrometer using hi...
Subhash Chand Kheruka,Brian F Hutton,Umesh Chand Naithani et al. Subhash Chand Kheruka et al.
Reconstruction of the tomographic images without attenuation correction can cause erroneously high count densities and reduced image contrast in low attenuation regions. In order to solve the problem of photon attenuation, one needs to know...
Reena Sharma,Sunil Dutt Sharma,Y S Mayya Reena Sharma
Kodak MinR-2000 mammography film is widely used for mammography imaging. The sensitometric indices like base plus fog level (B + F), maximum optical density (OD(max)), average gradient (AG) and speed of this film at varying development temp...