Comparing the level of bystander effect in a couple of tumor and normal cell lines [0.03%]
比较肿瘤和正常细胞系中旁观者效应的水平
Shokouhozaman Soleymanifard,Mohammad T Toossi Bahreyni
Shokouhozaman Soleymanifard
Radiation-induced bystander effect refers to radiation responses which occur in non-irradiated cells. The purpose of this study was to compare the level of bystander effect in a couple of tumor and normal cell lines (QU-DB and MRC5). To ind...
Christopher E Neilson,Slav Yartsev
Christopher E Neilson
Helical tomotherapy's ability to provide daily megavoltage (MV) computed tomography (CT) images for patient set-up verification allows for the creation of adapted plans. As plans become more complex by introducing sharper dose gradients in ...
Equivalent normalized total dose estimates in cyberknife radiotherapy dose delivery in prostate cancer hypofractionation regimens [0.03%]
调强放射治疗前列腺癌低分割方案的等效总剂量估算
H Sudahar,P G G Kurup,V Murali et al.
H Sudahar et al.
As the α/β value of prostate is very small and lower than the surrounding critical organs, hypofractionated radiotherapy became a vital mode of treatment of prostate cancer. Cyberknife (Accuray Inc., Sunnyvale, CA, USA) treatment for loca...
Impact of edema and seed movement on the dosimetry of prostate seed implants [0.03%]
水肿和种子移动对前列腺种子植入剂量学的影响
Ron S Sloboda,N Usmani,T T Monajemi et al.
Ron S Sloboda et al.
This article summarizes current knowledge concerning the characterization of prostatic edema and intra-prostatic seed movement as these relate to dosimetry of permanent prostate implants, and reports the initial application to clinical data...
Evaluation of PTW Seven29 for tomotherapy patient-specific quality assurance and comparison with ScandiDos Delta(4) [0.03%]
PTW Seven29托姆疗法患者特定质量检验的评估及与ScandiDos Delta(4)的比较
Pamela Myers,Sotirios Stathakis,Alonso N Gutiérrez et al.
Pamela Myers et al.
For routine quality assurance of helical tomotherapy plans, an alternative method, as opposed to the TomoTherapy suggested cylindrical solid water phantom with film and ionization chamber, is proposed using the PTW Seven29 2D-ARRAY inserted...
Christopher H Green
Christopher H Green
Nuclear Medicine developed when it was realised that a radioisotopic substitution of Iodine-131 for the stable Iodine-127 would follow the same metabolic pathway in the body enabling the thyroid to be imaged and the thyroid uptake measured....
A S Pradhan,J L Kim,J I Lee
A S Pradhan
Specific activities of natural rocks and soils at quaternary intraplate volcanism north of Sana'a, Yemen [0.03%]
也门萨那北部第四纪陆内火山岩和土壤的天然放射性水平
Shaban Harb,Abd El-Hadi El-Kamel,Abd El-Bast Abbady et al.
Shaban Harb et al.
The level of natural radioactivity in rocks and soil of 32 samples collected from locations at North Sana'a in Yemen was measured. Concentrations of radionuclides in rocks and soils samples were determined by gamma-ray spectrometer using hi...
A new method to correct the attenuation map in simultaneous transmission/emission tomography using Gd/Ga radioisotopes [0.03%]
一种新的方法用于使用Gd / Ga放射性同位素进行同时发射/发射断层扫描的衰减图校正
Subhash Chand Kheruka,Brian F Hutton,Umesh Chand Naithani et al.
Subhash Chand Kheruka et al.
Reconstruction of the tomographic images without attenuation correction can cause erroneously high count densities and reduced image contrast in low attenuation regions. In order to solve the problem of photon attenuation, one needs to know...
Light sensitometry of mammography films at varying development temperatures and times [0.03%]
不同显影温度和时间下的乳腺摄影胶片感光度测量
Reena Sharma,Sunil Dutt Sharma,Y S Mayya
Reena Sharma
Kodak MinR-2000 mammography film is widely used for mammography imaging. The sensitometric indices like base plus fog level (B + F), maximum optical density (OD(max)), average gradient (AG) and speed of this film at varying development temp...