Non-diffractive EDOF IOL Implantation After Combined DMEK and Cataract Surgery [0.03%]
后房非衍射扩展焦距人工晶状体植入联合DMEK和白内障手术中的应用
Antonio Cano-Ortiz,Álvaro Sánchez-Ventosa,Marta Villalba González et al.
Antonio Cano-Ortiz et al.
Purpose: To assess the efficacy of the AcrySof IQ Vivity non-diffractive extended depth of focus intraocular lens (EDOF IOL) (Alcon Laboratories, Inc) in patients with Fuchs' endothelial dystrophy undergoing Descemet memb...
Corneal Allograft for Near Vision Improvement in Emmetropic Presbyopia: 4-Year Safety and Efficacy Results From a Prospective European Multicenter Clinical Trial [0.03%]
前瞻性欧洲多中心临床研究的4年安全性和有效性结果:角膜异体移植改善正视老花眼近视力的研究
Aylin Kilic,Arthur Cummings,Pavel Stodulka et al.
Aylin Kilic et al.
Purpose: To evaluate both short- and long-term safety and effectiveness of intrastromal implantation of the corneal inlay for providing near vision in patients with presbyopia. ...
The Eyes Take Pictures [0.03%]
眼睛拍照
Enma Rico-Mezquida
Enma Rico-Mezquida
Texture-based Analysis of Corneal Dynamics for the Detection of Forme Fruste Keratoconus [0.03%]
基于纹理的角膜动态分析以检测早期 keratoconus 病情恶化风险
Shenglong Luo,Kuangching Lin,Xuefei Li et al.
Shenglong Luo et al.
Purpose: To propose CVS-omics, a radiomics framework using Corvis ST (CVS) (Oculus Optikgeräte GmbH) imaging and machine learning, for precise identification of forme fruste keratoconus (FFKC), a subtle corneal condition...
Rare but Serious: Infectious Keratitis After Femtosecond Laser-Assisted Arcuate Keratotomies in Cataract Surgery: A Case Series and Review of Literature [0.03%]
飞秒激光辅助的圆周形角膜切开术白内障手术后罕见但严重的感染性角膜炎:病例系列和文献综述
Daniel David,Michael Mimouni,Guy Kleinmann et al.
Daniel David et al.
Purpose: To present five cases of infectious keratitis following femtosecond laser-assisted cataract surgery combined with laser arcuate keratotomies (FLACS-AK). ...
Surgical Approach for the Implantation of a Ring Electrode into the Sulcus in a Phakic Non-human Primate [0.03%]
植入有晶体非人灵长类视网膜色素上皮下环状电极的手术方法
Friederike C Kortuem,Immanuel Seitz,Sebastian Kaltenstadler et al.
Friederike C Kortuem et al.
Purpose: To evaluate the feasibility of surgical implantation of electrical components needed for the operation of biomimetic artificial intraocular lenses (IOLs) for presbyopia correction in phakic non-human primates. Th...
VISULYZE: A Novel Nomogram Tool for Optimizing Refractive Outcomes in SMILE Surgery [0.03%]
VISULYZE:一种新颖的 nomogram 工具,用于优化 SMILE 手术的屈光效果
Juehan Li,Enze Liu,Haixia Ji et al.
Juehan Li et al.
Purpose: To evaluate a new nomogram technique, VISULYZE (Carl Zeiss Meditec AG), in small incision lenticule extraction (SMILE) surgery for treatment of myopia and myopic astigmatism. ...
Ten-Year Outcomes of Refractive Lens Exchange With Trifocal Intraocular Lenses in Patients With Mild to Moderate Amblyopia [0.03%]
三焦点人工晶状体屈光性白内障手术矫正轻至中度弱视的10年疗效观察
Markéta Brožková,Lenka Havlíčková,Magdaléna Vokrojová et al.
Markéta Brožková et al.
Purpose: To assess long-term visual outcomes and patient-reported satisfaction after refractive lens exchange (RLE) with trifocal intraocular lens (IOL) implantation in adults with mild to moderate amblyopia. ...
Central Vault and Anterior Chamber Angle Measurements After ICL Implantation: Repeatability and Reproducibility With a New Full-Range SS-OCT and Agreement With an Anterior Segment SS-OCT [0.03%]
ICL植入后的中心储液室和前房角测量:新型全范围SS-OCT的重复性和再现性与前节SS-OCT的一致性评估
Chak Seng Lei,Qinghao Meng,Xinyu Jiang et al.
Chak Seng Lei et al.
Purpose: To assess the intraobserver repeatability and interobserver reproducibility of central vault and anterior chamber angle (ACA) measurements obtained with the YG-100K (TowardPi Medical Technology Ltd), a new full-r...
Tolerance to Simulated Astigmatism and Patient-Reported Outcomes of a Violet Light-Filtering Diffractive Full Visual Range Intraocular Lens [0.03%]
一种新型紫色滤过分衍全视觉范围人工晶状体的散光耐受性及患者相关结果
Hugo T F Borges,Rupal H Trivedi,Munjal Pandya et al.
Hugo T F Borges et al.
Purpose: To assess the tolerance to simulated astigmatism and patient-reported outcomes in pseudophakic eyes implanted with a violet light-filtering diffractive full visual range intraocular lens (VLF FVR IOL). ...