Deep Learning-Accelerated 3D FLAIR Enables Reliable MS Lesion Detection [0.03%]
基于深度学习的3D FLAIR加速了可靠的多发性硬化病变检测
Sébastien Verclytte,Guillaume Beaugrard,Dominik Nickel et al.
Sébastien Verclytte et al.
Background and purpose: Deep learning-based reconstruction has the potential to shorten MRI acquisition while preserving diagnostic image quality, but its reliability for MS lesion detection on 3D FLAIR requires validatio...
Spinal CSF-Venous Fistulas as the Potential Cause of Chronic Subarachnoid Hemorrhage: Superficial Siderosis and Adhesive Arachnoiditis [0.03%]
脊髓脑脊液-静脉瘘作为慢性蛛网膜下腔出血的潜在原因:浅表铁沉积症和蛛网膜炎
Wouter I Schievink,Marcel M Maya,Simy K Parikh et al.
Wouter I Schievink et al.
Background and purpose: Spontaneous spinal CSF-venous fistulas were first described in 2014 and much remains unknown about this common cause of intracranial hypotension, including their basic pathophysiology. One point of...
Assessment of Cortical Myelination in Patients with MS via T1-Weighted/FLAIR Ratio: A Longitudinal Follow-Up Study [0.03%]
基于T1-FLAIR比值的MS患者皮层髓鞘化评估:一项纵向随访研究
Junsung Kim,Da-Young Seo,Eunseon Jeong et al.
Junsung Kim et al.
Purpose: The T1-weighted (T1W)/FLAIR ratio may reflect cortical myelin integrity in patients with MS (PwMS). This study aimed to investigate the longitudinal significance of the cortical T1W/FLAIR ratio in PwMS. ...
Improved safety of intracranial aneurysm coiling with OPTIMA™: Results of the INSTANT study [0.03%]
OPTIMA?™辅助下颅内动脉瘤栓塞的临床研究(INSTANT)结果:降低弹簧圈移位及复发,改善治疗效果
Laurent Pierot,Gaultier Marnat,Roberto Riva et al.
Laurent Pierot et al.
Background and purpose: Coiling remains a widely used, first-line endovascular treatment for intracranial aneurysms. However, recent large-scale evaluations are limited since the ARETA study, which assessed the safety and...
Preclinical in vivo results of the new generation coated FRED Flow Diverter [0.03%]
新一代涂层FRED流分流器的临床前体内结果
Géraud Forestier,Romain Chauvet,Maxime Baudouin et al.
Géraud Forestier et al.
Background: The introduction of coatings on flow diverter stents (FD) marks a significant evolution in neurovascular intervention for aneurysm embolization. FDs represent a major innovation in the treatment of intracrania...
Long-Term Outcomes of Wide-Neck Intracranial Aneurysms Treated with LVIS EVO-Assisted Coiling: A Multicenter Retrospective Study [0.03%]
采用LVIS EVO辅助线圈栓塞治疗宽颈颅内动脉瘤的长期疗效:一项多中心回顾性研究
Kubilay Aydin,Mani Puthuran,Yilmaz Onal et al.
Kubilay Aydin et al.
Background and purpose: Stent-assisted coiling (SAC) is a well-defined and widely performed endovascular technique used to treat wide-neck aneurysms. The Low-Profile Visualized Intraluminal Support (LVIS) EVO stent is a n...
Quality Management Practices in Neuroradiology: The Role of QC, QA, and QI [0.03%]
神经放射学中的质量管理实践:QC、QA和QI的作用
Robert Y Shih,Nadja Kadom
Robert Y Shih
Quality management in neuroradiology aims to achieve consistent excellent performance in patient care by integrating three complementary practices: quality control (QC), quality assurance (QA), and quality improvement (QI). These practices ...
Are the Small Intracranial Aneurysms of the Anterior Circulation Score Sensitive Enough to Discriminate Aneurysms at High Risk of Rupture? Retrospective Analysis of 193 Ruptured Aneurysms [0.03%]
前循环小型颅内动脉瘤评分量表能否有效识别易破裂动脉瘤?193例破裂动脉瘤回顾性分析
Benjamin A Buhot,Yann A Seznec,Loic J Villeneuve et al.
Benjamin A Buhot et al.
Background and purpose: The Small Intracranial Aneurysms of the Anterior Circulation (SIAAC) score was proposed in 2023 to stratify the rupture risk of small (
Internal Construct Assessment of the Perfusion Collateral Impairment Score: Component Independence and Outcomes Discrimination in LVO Stroke [0.03%]
关于LVO卒中患者中PERFUSE评分内部结构评估:组间独立性和结果区分度
Shankar Biswas,Hamza Adel Salim,Derek A Tsang et al.
Shankar Biswas et al.
Background: The Perfusion Collateral Impairment Score (PCIS), an ordinal composite (range 0-3) of hypoperfusion intensity ratio (HIR ≥ 0.4), cerebral blood volume index (CBVI < 0.8), and prolonged venous transit (PVT+), ...
AJNR Study-Specific Guidelines for AI in Medical Imaging: Bridging Gaps in Reference Standard and Clinical Evaluation [0.03%]
AJNR医学影像人工智能研究特定指南:参考标准和临床评估差距的桥梁
Janet Mei,Henk van Voorst,Seyedmehdi Payabvash et al.
Janet Mei et al.
The rapid proliferation of artificial intelligence (AI) applications in neuroradiology can lead to heterogeneous study design and reporting that impede reproducibility and clinical translation. To support authors submitting AI imaging resea...