Acute Cardiac Tamponade During Multiple Electrical Pre-Mappings for Atrial Leadless Pacemaker Implantation [0.03%]
腔内电位多次标测导致急性心包压塞一例
Ryuki Chatani,Akina Takauchi,Mitsuru Yoshino et al.
Ryuki Chatani et al.
Although cardiac tamponade during atrial leadless pacemaker implantation (ALPI) is rare, we encountered such an incident in a female patient with a lower body mass index during multiple pre-mapping attempts. During ALPI, operators should ai...
Zero Fluoroscopy Ablation of Arrhythmias in Patients With Congenital Heart Disease [0.03%]
无放射线消融治疗先天性心脏病患者的阵发性心律失常
Shailendra Upadhyay,Jenna Schermerhorn,Whitney Fairchild et al.
Shailendra Upadhyay et al.
Aims: Radiation-free catheter ablation is feasible with modern electroanatomic mapping systems. We aimed to evaluate the feasibility, safety, and outcomes of non-fluoroscopic ablation (NFA) in patients with congenital hea...
Managing Catheter Knotting in Pulse-Select Pulsed Field Ablation: Mechanisms and a Practical Strategy for Resolution [0.03%]
脉冲选择性脉冲场消融中导管缠绕的管理:机制及解决策略
Masateru Takigawa,Ryosuke Kato,Masaki Honda et al.
Masateru Takigawa et al.
Background: Pulsed field ablation (PFA) using the PulseSelect catheter is effective for atrial fibrillation but may occasionally result in catheter deformation or knotting. ...
Explosion Risk of Cardiac Implantable Electronic Devices During Cremation: Experimental and Survey Findings From Japan [0.03%]
日本火化过程中心脏植入式电子装置爆炸风险的实验和调查结果
Takanori Arimoto,Yasushi Oginosawa,Katsuya Ebe et al.
Takanori Arimoto et al.
Background: The widespread use of cardiac implantable electronic devices (CIEDs), combined with increasing global cremation rates, has raised concerns regarding potential explosion risks during cremation. Lithium batterie...
The Evolving Role of Ivabradine for Focal Atrial Tachycardia: A Systematic Review [0.03%]
伊伐布雷定治疗局灶性房速作用的再评价:系统综述
Haikal Balweel,Rifqi Rizkani Eri,Sania Zahrani et al.
Haikal Balweel et al.
Background: Ivabradine was initially introduced for heart failure and coronary artery disease patients, with its interesting feature of heart rate reduction without reducing heart contractility or blood pressure. In recen...
An Intraoperative Fluoroscopic Predictor of Successful Micra Implantation on the Right Ventricular Mid-Septum [0.03%]
术中透视下预测右心室隔壁Micra植入成功的指标
Misun Pak,Ken Kakita,Takashi Yamasaki et al.
Misun Pak et al.
Background: The Micra transcatheter pacing system has been adopted globally. However, the procedural parameters for safe Micra implantation on the ventricular wall, particularly in the mid-septum, remain unknown. This stu...
Implantable Cardioverter-Defibrillators in Children: A 14-Year Population-Based Study [0.03%]
儿童植入式心脏复律除颤器的使用:一项为期14年的基于人口的研究
Marko Bjeloševič,Peter Olejník,Jaroslav Tomko et al.
Marko Bjeloševič et al.
Aims: Implantable cardioverter-defibrillator (ICD) therapy in children, particularly for primary prevention, remains under investigation, with limited data from less affluent European countries. With increasing use of ful...
Kuwait Atrial Fibrillation Management Analysis-Insights From a Tertiary Center in Kuwait [0.03%]
Kuwait心房颤动管理分析——来自科威特三级医疗中心的见解
S AlKharji,S A Almoosawy,J AlBalool et al.
S AlKharji et al.
Background: Real-world data on atrial fibrillation (AF) contemporary management from the Gulf region are scarce and nonexistent from Kuwait. Despite recent guideline updates favoring early rhythm control, clinical charact...
Reduced Vascular Complications After Catheter Ablation Applying Sonography-Guidance and Modified Postprocedural Care [0.03%]
经声学造影指导的射频消融结合改良术后护理可减少并发症发生率
Niklas Schenker,Julius Obergassel,Charlotte Asbeck et al.
Niklas Schenker et al.
Background: Vascular access and postprocedural access site management remain the leading causes for postprocedural complications following interventional electrophysiological (EP) procedures. ...
Anatomical Predictors of Optimal Cryoballoon Size Selection: A Prospective Comparison of 28 mm Versus 31 mm Size-Adjustable Balloon Modes [0.03%]
最佳冷冻球囊大小选择的解剖预测因素:前瞻性比较28mm与31mm可调式球囊模式
Reisuke Yoshizawa,Takeshi Sasaki,Harutomo Numazaki et al.
Reisuke Yoshizawa et al.
Background: Complete pulmonary vein (PV) occlusion is critical for successful cryoballoon ablation. The POLARx FIT size-adjustable cryoballoon adjusts diameter from 28 to 31 mm. This study aimed to compare PV occlusion gr...