A case report of bycross rotational atherectomy followed by drug-coated balloon angioplasty for deep femoral artery atherosclerotic disease [0.03%]
深股动脉粥样硬化性疾病逆向旋切联合药物涂层球囊扩张成形术一例报告
Enrique M San Norberto,Álvaro Revilla,José A Brizuela et al.
Enrique M San Norberto et al.
Endovascular techniques have been proposed as an alternative to open repair for lesions of the femoral bifurcation and origin of the deep femoral artery (DFA). Debulking prior to drug-coated balloon angioplasty might improve the technical s...
Minimally invasive repair of acute type A aortic dissection: early experience in selected population [0.03%]
急性A型主动脉夹层微创外科治疗的早期应用经验及其适应证探讨
Francesco Cabrucci,Beatrice Bacchi,Massimo Baudo et al.
Francesco Cabrucci et al.
Background: The aim of this study was to evaluate the feasibility of minimally invasive repair of type A aortic dissection (MIR-TAAD) using mini sternotomy (MS), which improves early outcomes, and to assess its suitabilit...
Ten-year outcome after HeartMate 3 left ventricular assist device implantation [0.03%]
HeartMate 3左心室辅助装置植入术10年效果分析
Jasmin S Hanke,Günes Dogan,Ali S Merzah et al.
Jasmin S Hanke et al.
Background: The HeartMate 3 left ventricular assist device (HM3, Abbott, U.S.A.) (LVAD) was first implanted in humans in 2014 at Hannover Medical School, Germany. This report presents the most extended single-center follo...
Comparison of visibility and material properties of the iCover and VBX stent grafts when used as bridge stents in fenestrated endografts. An in-vitro study [0.03%]
iCover和VBX支架移植物用作开孔内血管内移植物桥的可视性和材料属性的比较:体外研究
Carla L Blanco Amil,Gaspar Mestres,Donovan Ruiz et al.
Carla L Blanco Amil et al.
Background: To in-vitro compare different material properties of two balloon-expandable covered-stents, VBX (W.L. Gore & Associates, Flagstaff, AZ, USA) and iCover (iVascular, Barcelona, Spain), as bridging stents in fene...
Physician-modified endografts for left subclavian artery revascularization during aortic arch and descending thoracic endovascular repair: a literature review and center experience [0.03%]
改良型内血管移植物在主动脉弓和降主动脉腔内修复术中左侧无名动脉重建中的应用:文献回顾与中心经验
Andrea Kahlberg,Nicola Favia,Ferdinando B Valente et al.
Andrea Kahlberg et al.
Background: Management of the left subclavian artery (LSA) during thoracic endovascular aortic repair (TEVAR) in zone 2 remains debated, as intentional coverage without revascularization increases the risk of cerebrovascu...
Custom-made left subclavian artery branch stent graft: experience of a single center [0.03%]
定制左位锁骨下动脉分支支架移植物的单中心经验研究
Martina Cambiaghi,Giacomo Bianco,Andrea Melloni et al.
Martina Cambiaghi et al.
Background: Endovascular strategies represent minimally invasive and valid alternatives to surgical debranching for left subclavian artery (LSA) revascularization in Zone 2 thoracic endovascular aneurysm repair (TEVAR). T...
Surgical options of left subclavian artery revascularization in the endovascular repair of the aortic arch [0.03%]
主动脉弓内脏修复中左位无名动脉旁路手术方式的选择
Enrico Gallitto,Paolo Spath,Stefania Caputo et al.
Enrico Gallitto et al.
Background: Management of the left subclavian artery (LSA) is necessary to reduce the risk of stroke and spinal cord ischemia, when endovascular repair of thoracoabdominal and aortic arch pathologies requires proximal lan...
Anatomy and possible variants of left subclavian artery and vertebral arteries [0.03%]
左椎动脉和左锁骨下动脉的解剖及变异学说
Ahmed Eleshra,José I Torrealba,Giuseppe Panuccio et al.
Ahmed Eleshra et al.
Introduction: The left subclavian artery (LSA) and vertebral arteries (VAs) undergo complex embryological development, resulting in a wide spectrum of anatomical variants. These variations are of significant clinical rele...
Evaluating the reliability and guideline concordance of ChatGPT-5 in the management of vascular diseases: a cross-sectional expert-based assessment [0.03%]
基于专家的横断面评估ChatGPT-5在血管疾病管理中的可靠性和符合指南情况
Üzeyir Yilmaz,Mehmet I Yeşilkaya
Üzeyir Yilmaz
Background: Artificial intelligence (AI) tools such as large language models are increasingly used in clinical decision support, yet their reliability in vascular medicine remains uncertain. This study evaluated the accur...
The role of IVUS in BEVAR as additional intraoperative tool: procedure guidance and quality control imaging [0.03%]
IVUS在BEVAR中的作用:作为术中辅助工具的操作引导和质量控制影像技术
Michele Piazza,Carmine Spiezia,Francesco Squizzato et al.
Michele Piazza et al.
Background: Intravascular ultrasound (IVUS) is a catheter-based imaging technique that utilizes high-frequency sound waves to produce real-time, cross-sectional images of the vessel lumen. IVUS is a well-known endovascula...