Kinetics of C-reactive protein during extracorporeal membrane oxygenation [0.03%]
体外膜氧合时C反应蛋白的动态变化规律
Yael Lichter,Amir Gal Oz,Uri Carmi et al.
Yael Lichter et al.
Background: The exposure of blood to the artificial circuit during extracorporeal membrane oxygenation (ECMO) can induce an inflammatory response. C-reactive protein (CRP) is a commonly used biomarker of systemic inflamma...
Observational Study
The International journal of artificial organs. 2024 Jan;47(1):41-48. DOI:10.1177/03913988231213511 2024
Comparison of different 3D printers in terms of dimensional stability by image data of a dry human mandible obtained from CBCT and CT [0.03%]
基于CBCT和CT的干人下颌骨图像数据评估不同3D打印机的尺寸稳定性
Hilal Peker Ozturk,Simel Ayyıldız
Hilal Peker Ozturk
Objectives: To manage the mandibular traumas, for the expression of the complex anatomy or pathology in education of health sciences related branches, a model of the traumatized mandible is indispensable. For these, diffe...
An analytic method to investigate hemodynamics of the cardiovascular system - single ventricular system [0.03%]
分析法研究心血管系统-单心室系统血液动力学问题
Yuxin Zhu,Wanning Ge,Tingting Wu et al.
Yuxin Zhu et al.
Based on the lumped parameter model (LPM) of the cardiovascular system, an analytic method is developed to derive its hemodynamics theoretically. As soon as the LPM (a series of differential equations) is solved, the hemodynamics would be o...
Extracorporeal blood purification with Oxiris® filter in critically ill patients with COVID-19 requiring continuous renal replacement therapy [0.03%]
COVID-19危重症连续性血液净化患者的体外血液循环 Oxiris膜滤器的应用
Mohamed Abdelaty,Adham Mohamed,Mohamed O Saad et al.
Mohamed Abdelaty et al.
Introduction: Severe COVID-19 is associated with a dysregulated immune response that usually leads to cytokine release syndrome. This study aimed to compare the use of extracorporeal blood purification therapy (Oxiris®) ...
Effects of biventricular shunt on pump characteristics in a maglev total artificial heart [0.03%]
双向分流对磁悬浮全人工心脏泵功能的影响研究
Shuya Shida,Kenichi Tsushima,Masahiro Osa et al.
Shuya Shida et al.
Severe left ventricular failure can progress to right ventricular failure, necessitating alternatives to heart transplantation, such as total artificial heart (TAH) treatment. Conventional TAHs encounter challenges associated with miniaturi...
Optimal treatment of tannic acid for the anti-calcification of bovine jugular veins and the underlying mechanism [0.03%]
没食子酸处理牛颈静脉的抗钙化最佳方法及其机制研究
Aili Wang,De Wang,Yumiao Wang et al.
Aili Wang et al.
Objectives: To evaluate the effects of combined treatment with tannic acid and ferric ions on the biomechanical and anti-calcification properties of glutaraldehyde-fixed bovine jugular veins after xenografting. ...
Normothermic ex vivo perfusion of deceased donor kidneys and its clinical potential in kidney transplantation outcomes [0.03%]
尸供肝肾脏体外 normothermic 灌注及其对移植受者结果的临床影响
Meghan Unes,Kento Kurashima,Yasar Caliskan et al.
Meghan Unes et al.
In recent years, normothermic machine perfusion (NMP) has emerged in conversation surrounding organ preservation and transplantation techniques with the goal of improving patient and clinical outcomes. This is in great attempt to address th...
Effect of low-calcium and standard-calcium dialysate on serum calcium, phosphorus and full-segment parathyroid hormone in patients on peritoneal dialysis: A retrospective observational study [0.03%]
低钙与常规透析液对腹膜透析患者血钙、血磷及全线甲状旁腺激素的影响:回顾性观察研究
Ning An,Haishan Zhou,Xianhui Li et al.
Ning An et al.
Objective: To investigate the effects of low-calcium and standard-calcium dialysate in patients with chronic kidney disease on peritoneal dialysis, and find out which dialysate has less vascular calcification effect. ...
Biomechanical effects of iatrogenic muscle-ligaments complex damage on adjacent segments following posterior lumbar interbody fusion: A finite element analysis [0.03%]
后路腰椎融合术所致医源性肌-韧带复合体损伤对邻近节段生物力学影响的有限元分析
Wei Wei,Tianhao Wang,Jian Li et al.
Wei Wei et al.
Objective: To analyze the biomechanical effects of proximal iatrogenic muscle-ligaments complex (MLC) damage on adjacent segments following posterior lumbar interbody fusion (PLIF) by finite element (FE) analysis. ...