Andrea Remuzzi
Andrea Remuzzi
N-succinyl chitosan-oxidized hyaluronic acid-calcium chloride hydrogel as hemostatic agent [0.03%]
n-丁二酰基壳聚糖交联透明质酸钙凝胶止血材料
Prihartini Widiyanti,Wahyu Addin Pratama
Prihartini Widiyanti
This study aims to develop an effective hemostatic agent in the management of irregular and deep wounds that can accelerate the hemostatic process. The background revealed the importance of rapid treatment of bleeding, with data showing a s...
Performance study of dual heart assisted control system based on SL-SMC physiological combination controller [0.03%]
基于生理组合控制器的双泵辅助心脏控制系统的性能研究
Fangqun Wang,Fan Xu,Fenglian Zhu et al.
Fangqun Wang et al.
The main challenges of Biventricular Assist Devices (BiVAD) as a treatment modality for patients with Bicardiac heart failure heart failure are the balance of systemic blood flow during changes in physiological activity and the prevention o...
Depurative capacity toward medium molecules of the dialyzer Toray NV-U® Hydrolink™: A new hydrophilic membrane to perform online hemodiafiltration [0.03%]
一种新型亲水性血液透析膜的中分子通透性:在线血滤治疗用Toray NV-U® Hydrolink™透析器
Maria Kislikova,Almudena Vega,Eduardo Verde et al.
Maria Kislikova et al.
Introduction: New dialysis membranes with new properties are being developed to improve efficacy and tolerance. The hemocompatibility of a polymeric biomaterial is influenced by the layer of water at the blood membrane in...
Assessment of haemolysis models for a positive-displacement total artificial heart [0.03%]
正位移式全人工心脏溶血模型的评估
Joseph Bornoff,Shaikh Faisal Zaman,Azad Najar et al.
Joseph Bornoff et al.
The assessment and reduction of haemolysis within mechanical circulatory support (MCS) remains a concern with regard to device safety and regulatory approval. Numerical methods for predicting haemolysis have typically been applied to rotary...
Impact of extracorporeal hemadsorption on mortality in critically ill COVID-19 patients in the intensive care unit [0.03%]
体外血吸附技术对重症监护室新型冠状病毒肺炎危重患者病死率的影响
Özlem Çakin,Melike Yüce Aktepe,Orbay Harmandar et al.
Özlem Çakin et al.
Background: The consequences of COVID-19, such as respiratory failure and mortality, require the search for fast and effective solutions. The aim of this retrospective study is to determine the effect of extracorporeal he...
Dynamic VAD simulations: Performing accurate simulations of ventricular assist devices in interaction with the cardiovascular system [0.03%]
动态VAD模拟:准确执行VAD与心血管系统相互作用的仿真模型
Vincenz Crone,Mario Hahne,Finn Knüppel et al.
Vincenz Crone et al.
Medical advancements, particularly in ventricular assist devices (VADs), have notably advanced heart failure (HF) treatment, improving patient outcomes. However, challenges such as adverse events (strokes, bleeding and thrombosis) persist. ...
Flexible inner surface of polysulfone membranes prevents platelet adhesive protein adsorption and improves antithrombogenicity in vitro [0.03%]
基于柔性内表面的聚砜膜防蛋白吸附及抗凝血性能研究
Ryo Takatsuji,Masahide Koremoto,Yoko Fujimoto et al.
Ryo Takatsuji et al.
Background: We investigated whether the condition of the inner surface of hollow fibers affects the blood compatibility of hemodialyzers. Methods: ...
Gabriella Bottari,Isabella Guzzo
Gabriella Bottari