Multinational prospective cohort study of incidence and risk factors for central line-associated bloodstream infections over 18 years in 281 ICUs of 9 Asian countries [0.03%]
亚洲九个国家281个ICU中心静脉导管相关性血流感染发生率和危险因素的多国前瞻性队列研究(长达18年)
Victor Daniel Rosenthal,Ruijie Yin,Camilla Rodrigues et al.
Victor Daniel Rosenthal et al.
Background: Our objective was to identify central line (CL)-associated bloodstream infections (CLABSI) rates and risk factors (RF) in Asia. Methods: ...
Two mattress suture: A useful technique to prevent bleeding in tunneled catheter insertion [0.03%]
双被套缝合技术在隧道式导管置入术中止血的应用价值
Morteza Khavanin Zadeh,Haleh Chehrehgosha
Morteza Khavanin Zadeh
Introduction: The implant of tunneled catheters, may be associated with some complications such as bleeding after insertion. We aimed this study to present a modified method for catheter insertion to prevent bleeding afte...
Chest-to-arm tunneling technique for central venous access devices in neonates [0.03%]
新生儿中心静脉通路装置的胸壁至手臂隧道技术
Carmen Rodriguez Perez,Elena Pezzotti,Francesco Maria Risso
Carmen Rodriguez Perez
Background: Chest-to-arm (CTA) tunneling technique has been described recently as an alternative option to exit site of the catheter in the infraclavicular area. ...
Hemodialysis access flow measurement: Comparison of ultrasound dilution and ultrafiltration method on NIKKISO DBB-EXA™ dialysis machine [0.03%]
尼科西DBB-EXA血液透析机的超声稀释法和超滤法测量血管通路血流量比较研究
Georgios Kosmadakis,Ioana Enache,Claudine Gueret et al.
Georgios Kosmadakis et al.
Background: The methods of estimating vascular access (VA) flow rates are usually based on the indicator dilution theory by measuring recirculation during dialysis sessions. ...
Registered Nurses' Association of Ontario (RNAO) best practice guideline on the assessment and management of vascular access devices [0.03%]
《血管通路装置的评估与管理》(加拿大安大略省注册护士协会最佳护理实践指南)
Christine Buchanan,Amy Burt,Nancy Moureau et al.
Christine Buchanan et al.
Introduction: Vascular access is the most common invasive procedure performed in health care. This fundamental procedure must be performed in a safe and effective manner. Vascular access devices (VADs) are often the sourc...
Comparative effectiveness of bovine carotid artery xenograft and polytetrafluoroethylene in hemodialysis access revision [0.03%]
家畜颈动脉异种移植物与聚四氟乙烯在维持性血液透析通路再修中的有效性比较研究
Patrick Heindel,Jessica D Feliz,James J Fitzgibbon et al.
Patrick Heindel et al.
Background: When hemodialysis arteriovenous accesses fail, autogenous options are often limited. Non-autogenous conduit choices include bovine carotid artery xenografts (BCAG) and expanded polytetrafluoroethylene (PTFE), ...
Mohamed Hassanein,Yeshwanter Radhakrishnan,Nora Hernandez Garcilazo et al.
Mohamed Hassanein et al.
The development of vascular access for hemodialysis has come a long way since 1943 when the first hemodialysis treatment was performed in humans by connecting an artery and vein using an external glass canula. Since then, vascular access ca...
Critical innovation to support improved hemodialysis access creation surgery and patient care [0.03%]
关键创新支持改善血液透析通路外科手术及患者护理
Joseph Patrick Hart
Joseph Patrick Hart
Answer to the article: Transonic® and DMed NephroFlow® vascular access flow measurements are not interchangeable [0.03%]
Transonic®和DMed NephroFlow®血管通路血流测量结果不可互换性
Jose Luis Merino,Esther García,David Varillas-Delgado et al.
Jose Luis Merino et al.