Guidewire replacement of valved tunneled-cuffed silicone catheters with power injectable polyurethane tunneled-cuffed catheters or with ports [0.03%]
带有阀门的硅胶隧道式囊袋导管与可高压注射的聚氨酯隧道式囊袋导管或植入式输液港的更换比较研究
Stefano Benvenuti,Federico Finetti,Elena Porteri et al.
Stefano Benvenuti et al.
Background: Silicone Cuffed Centrally Inserted Central venous catheters (CICCs) were a type of catheters that have been used for a long time especially in cancer patients. Recently, thanks to biomedic research progresses,...
FLOW: Flow dysfunction of hemodialysis vascular access: A randomized controlled trial on the effectiveness of surveillance of arteriovenous fistulas and grafts [0.03%]
血液透析血管通路的血流动力学功能障碍:关于动静脉瘘和移植物监测有效性的随机对照试验
Bianca Zomer,Matthijs S Ruiter,Friedo W Dekker et al.
Bianca Zomer et al.
Introduction: It is assumed that identification and correction of asymptomatic stenoses in the vascular access circuit will prevent thrombosis that would require urgent intervention to continue hemodialysis treatment. How...
Response letter [0.03%]
回应信函
Letty V van Vliet,Tammo Delhaas,Barend Me Mees et al.
Letty V van Vliet et al.
Elimination of bleeding after tunnelled catheter removal by modified technique in practice [0.03%]
改良技术实践在隧道式导管移除后止血中的应用
Morteza Khavanin Zadeh,Haleh Chehrehgosha
Morteza Khavanin Zadeh
Intracavitary electrocardiogram guidance for peripherally inserted central catheter placement in a patient with persistent left superior vena cava: A case report [0.03%]
周围插入中心导管置于持续性左上腔静脉患者的经腔内心电图引导:病例报告
Yuejiao Zhang,Ruiyi Zhao
Yuejiao Zhang
Intracavitary electrocardiogram (IC-ECG) guidance is widely used for peripherally inserted central catheter (PICC) placement. The P wave variation has rarely been reported in persistent left superior vena cava (PLSVC). Here, we report a PLS...
Fatal superior vena cava rupture complicating dialysis catheter exchange [0.03%]
透析导管更换合并致命性上腔静脉破裂并发症
Ahmed E Ali,Alian Al-Balas,Paul V Benson et al.
Ahmed E Ali et al.
Central vein stenosis (CVS) is a common and challenging complication in hemodialysis patients with chronic central venous catheters (CVCs). CVS often remains asymptomatic and is discovered incidentally during follow-up imaging. CVS symptoms...
Integrated short peripheral intravenous cannulas and risk of catheter failure: A systematic review and meta-analysis [0.03%]
一体化短周边静脉导管和导管失效的风险:系统性回顾和荟萃分析
Antonio Gidaro,Massimiliano Quici,Davide Giustivi et al.
Antonio Gidaro et al.
Background: Short peripheral catheters (SPCs) are used to provide intravenous therapies in hospitalized patients. Recently, the category of SPC has become more complex, with the introduction in clinical practice of "integ...
Cannula associated deep vein thromboses in COVID-19 patients supported with VV ECMO [0.03%]
使用VV ECMO治疗的COVID-19患者中导管相关深静脉血栓形成
Erin Niles,Mary Maldarelli,Joseph Hamera et al.
Erin Niles et al.
Background: VV ECMO is increasingly used as a rescue strategy for hypercarbic and hypoxic respiratory failure refractory to conventional management, and more than 14,000 patients with COVID-19 related respiratory failure ...
Predicting recurrent interventions after radiocephalic arteriovenous fistula creation with machine learning and the PREDICT-AVF web app [0.03%]
基于机器学习的PREDICT-AVG网络应用程序预测桡动脉吻合血管瘘术后复发性干预措施的可能性
Patrick Heindel,Tanujit Dey,James J Fitzgibbon et al.
Patrick Heindel et al.
Objective: Kidney Disease Outcomes Quality Initiative (KDOQI) guidelines discourage ongoing access salvage attempts after two interventions prior to successful use or more than three interventions per year overall. The go...
Effect of flow reduction surgery in a patient with high flow arteriovenous fistula with aortic dissection using 4D flow magnetic resonance imaging: A case report [0.03%]
采用4D流磁共振成像技术报告动静脉瘘伴主动脉夹层病人流量减少手术的效果
Yeongrok Oh,Chang Min Heo,Sangeon Gwoo et al.
Yeongrok Oh et al.
This study aimed to investigate cardiovascular function in a patient with high-flow arteriovenous fistula (AVF) who underwent aortic dissection (AD) using four-dimensional (4D) flow magnetic resonance imaging (MRI) as well as analyze the ef...