Assessing the time-to-removal of totally implantable venous access devices comparing valved-versus open-ended catheters in patients treated with chemotherapy [0.03%]
评估化疗患者中使用阀控与开放式导管的完全植入式静脉通路装置的移除时间
Koceila Amroun,Mathias Brugel,Rami Rhaiem et al.
Koceila Amroun et al.
Background: Totally IntraVenous Acess Devices (TIVAD) are used to have long-term bloodstream access. The catheter connected to the subcutaneous chamber may be valved (TIVAD-V) or open-ended (TIVAD-O). Infectious and occlu...
Distal AVF creation with marginal calcified radial artery: Multicentric experience of intraoperative intravascular lithotripsy [0.03%]
边缘钙化桡动脉的远端AVF创建:术中血管内碎石术的多中心经验
Napoli Marcello,Taurisano Marco,Covella Patrizia et al.
Napoli Marcello et al.
Introduction: The first-choice vascular access to starting dialysis in patients with End Stage Renal Disease (ESRD) is autogenous distal arteriovenous-fistula (AVF) to spare vascular district avoiding proximal fistula com...
Implementation of a vascular access team and an intravenous therapy programme: A first-year activity analysis [0.03%]
血管通道小组及静脉输液项目实施情况分析——首年活动分析
Arianna Rosich-Soteras,Carolina Bonilla-Serrano,Ma Àngels Llauradó-González et al.
Arianna Rosich-Soteras et al.
Background: Creating Vascular Access Teams (VAT) provides an expert nursing role that contributes to the training and continuous improvement of healthcare personnel. They can offer greater clinical safety, reducing compli...
Alternative dialysis access strategies: A case report of a patient with transrenal hemodialysis catheter due to exhausted traditional routes and review of literature [0.03%]
肾内血液透析导管透析的非常规通路建立策略:传统血管通路耗竭患者的诊治体会及文献复习
Maysam Shehab,Igal Griton,Stanislav Kosykh et al.
Maysam Shehab et al.
Vascular access is the primary lifeline for patients with end-stage renal disease. While arteriovenous fistulas and grafts are the conventionally favored methods for dialysis therapy, certain patients may deplete these traditional vascular ...
Efficacy and safety of implantable vascular support in the treatment of arteriovenous fistula: A single-arm meta-analyses [0.03%]
血管支架植入治疗动静脉瘘的有效性和安全性:单臂Meta分析
Xuanwei Li,Congyuan Ma,Wenlai Li et al.
Xuanwei Li et al.
Background and objectives: VasQ (Laminate Medical Technologies, Israel) is an external support device for autologous arteriovenous fistula (AVF) designed to improve anastomotic blood flow and reduce neointimal hyperplasia...
Comparison of procedural time with two different ultrasound-guided approaches for dorsalis pedis artery cannulation in adult patients: A randomized trial [0.03%]
两种不同超声引导方法在成人患者足背动脉穿刺中的操作时间比较:一项随机试验
Priyabrat Karan,Ankur Sharma,Arun Mukesh et al.
Priyabrat Karan et al.
Background: In adult patients, there has never been an evaluation of short-axis out-of-plane versus long-axis in-plane approaches of ultrasound-guided dorsalis pedis artery cannulation. This research was conducted to comp...
A 4-year tunneled hemodialysis catheter malpositioned into the azygos vein and how to remedy the hemodialysis circuit [0.03%]
误置于奇静脉的长期隧道型血透导管及如何补救血透通路
Yuqin Xiong,Qiuyan Zhao,Yang Yu et al.
Yuqin Xiong et al.
Mispositioning in the azygos vein is a rare but hazardous complication of central venous catheterization. A patient was admitted for a dysfunctional hemodialysis tunneled cuffed catheter (TCC) placed in the azygos vein for 4 years. Computed...
Systematic review and meta-analysis comparing Manta device and Perclose device for closure of large bore arterial access [0.03%]
系统回顾和荟萃分析比较Manta装置和Perclose装置对于大口径动脉通路的闭合效果
Tayyab Cheema,Carmelo Venero Jr,Shivam Champaneria et al.
Tayyab Cheema et al.
Data comparing MANTA device with Perclose device for large bore arterial access closure is limited. We performed meta-analysis to compare safety and efficacy of the two devices in large (⩾14 Fr sheath) arteriotomy closure post-TAVR. Releva...
Evaluating the impact of external forces on peripheral intravenous catheter movement using ultrasound: A randomized pilot study [0.03%]
使用超声波评估外力对周围静脉导管移位的影响的随机预试验研究
Amit Bahl,Vance Clement,Emily DiLoreto et al.
Amit Bahl et al.
Background: A major contributor to peripheral intravenous catheter (PIVC) failure may be related to PIVC movement within the vein which is associated with vein wall damage. The magnitude of PIVC movement against the vein ...
A standardized educational program to improve peripheral vascular access outcomes in the emergency department: A quasi-experimental pre-post trial [0.03%]
急诊科外周血管通路结果改善的标准化教育项目:准实验性试验研究
Amit Bahl,Nicholas Mielke,Yuying Xing et al.
Amit Bahl et al.
Objective: Difficult intravenous access (DIVA) patients are known to have disproportionately poorer vascular access outcomes. The impact of education and training on vascular access outcomes in this vulnerable population ...