Evaluation of domain shift sources and generalisability in AI-based prostate MRI autocontouring for radiotherapy [0.03%]
基于人工智能的前列腺MRI自动勾画的领域偏移及泛化能力评估
Maram Alqarni,Emma-Louise Jones,Vinod Mullassery et al.
Maram Alqarni et al.
Aim: Deep learning (DL) models have been widely proposed to automate MRI-based delineation, but their use is hindered by differences in image characteristics between training and evaluation datasets (i.e. domain shift). T...
Toward the use of Silicon Carbide based detector for protontherapy microdosimetry [0.03%]
基于碳化硅的检测器在质子治疗微剂量学中的应用探讨
G Petringa,C Verona,R Catalano et al.
G Petringa et al.
Purpose: This study explores the potential of a Silicon Carbide (SiC)-based microdosimeter for use in proton therapy. Thanks to its high radiation hardness, minimal leakage current, and stable charge collection efficiency...
Patterns of practice of image guided particle therapy for brain tumours: A site specific multi-institutional survey of the European particle therapy network [0.03%]
欧洲粒子治疗网络的多机构调查:脑肿瘤图像引导粒子治疗的实践模式
Iuliana Toma-Dasu,Alexandru Dasu,Dante Amelio et al.
Iuliana Toma-Dasu et al.
Purpose: To investigate the current practice patterns in image-guided proton therapy (IGPT) for brain tumours. Methods: A multi-institu...
Corrigendum to "CAD-based Monte Carlo dose calculation system for evaluating geometrical effect of inserted materials in carbon-ion radiation therapy" [Phys. Med. 136 (2025) 105051] [0.03%]
关于“基于计算机辅助设计的蒙特卡罗剂量计算系统,用于评估碳离子放射治疗中插入材料的几何效应”的勘误修正通知书
Min Cheol Han,Yongdo Yun,Taeho Kim et al.
Min Cheol Han et al.
Elizabeth Claridge Mackonis,Anna Ralston,Johnson Yuen et al.
Elizabeth Claridge Mackonis et al.
Purpose: Whilst a formal prospective risk assessment is an important part of risk management in the implementation of new techniques and technologies, a lack of time and practical knowledge can prevent its use. Here we pr...
Dose distribution of secondary radiation in a water phantom for a spatially fractionated proton beam [0.03%]
空间分割质子束在水中模体二次辐射剂量分布分布
A Tobola-Galus,L Stolarczyk,I Ambrožová et al.
A Tobola-Galus et al.
Objective: 3D mapping of scattered radiation doses in water after grid proton irradiation using a dedicated brass collimator was performed within the EURADOS experiment at the scanning gantry of the Cyclotron Centre Brono...
Insights, robustness and practical considerations of global noise level measurement in chest CT [0.03%]
胸部CT检查全球噪声水平测量的见解、鲁棒性及实用注意事项
Kwinten Torfs,Dimitar Petrov,Louise Dhondt et al.
Kwinten Torfs et al.
Background: Accuracy of global noise level (GNL) has been benchmarked predominantly for soft tissue. This work extends the use of GNL to lung tissue and investigates the effect of patient, protocol and method parameters o...
Knowledge-based automated radiation therapy treatment planning utilizing dose prediction with a 2.5D-U-Net [0.03%]
基于剂量预测的智能化射波刀放射治疗计划系统研究及应用
H Oppitz,M Eckl,K Siebenlist et al.
H Oppitz et al.
Purpose: Inverse treatment planning (ITP) in intensity modulated radiation therapy (IMRT) involves the specification of dose constraints as objective functions. These are manually and iteratively adjusted during planning ...
Evaluating the accuracy of SPECT/CT LSF estimations in SIRT therapies using Monte Carlo simulations with virtual 4D anthropomorphic phantoms [0.03%]
使用虚拟4D人体模型的蒙特卡洛模拟评估SIRT治疗中SPECT / CT LSF估算的准确性
Niamh McArdle,Jackie McCavana,Darragh McCague et al.
Niamh McArdle et al.
Purpose: Recent publications advocate the use of SPECT/CT for LSF estimation for more accurate lung dose estimations in Selective Internal Radiation Therapy (SIRT) treatments. These studies have been limited to patient st...
Corrigendum to "Evaluation of cumulative radiation burden and associated risk in smouldering multiple myeloma patients monitored using recurrent whole-body low-dose CT imaging". [Phys. Med. 138 (2025) 105173] [0.03%]
“关于”反复全身低剂量CT监测下的缓慢进行性多发性骨髓瘤患者辐射累积负担及风险评估“的更正公告_phys.Med._138_105173()的研究论文修正公告
Pascaline Wangechi Abissi,Georgia Lymperopoulou,Vasileios-Petros Agrokostas et al.
Pascaline Wangechi Abissi et al.