Female Anterior Cruciate Ligaments Exhibit a Muted Mechanobiological Response to Mechanical Loading [0.03%]
载荷下女性前交叉韧带的低力学生物学响应
Lauren Paschall,Maxwell Konnaris,Erdem Tabdanov et al.
Lauren Paschall et al.
Female athletes are significantly more likely to tear their anterior cruciate ligament (ACL) compared to their male counterparts. While there are several potential reasons for this, previous data from our lab demonstrated that female ACL ex...
Personalization and Precision: Innovative Applications and Future Challenges of Additive Manufacturing in Orthopedic Implants [0.03%]
个性化与精准化:骨科植入物增材制造的创新应用及未来挑战
Puzhen Wu,Xinrui Liu,Ziyu Guo et al.
Puzhen Wu et al.
When significant structural defects (such as post tumor removal or severe bone defect) exceed the body's inherent capacity for self-repair, orthopedic implants remain an effective clinical option for restoring skeletal structural integrity ...
The Effect of Implant Size on Fretting Currents of Acetabular Cup-Liner Tapers During in Vitro Cyclic Loading [0.03%]
假体大小对体外循环加载下髋臼杯-内衬锥形结构 fretting 电流的影响研究
Peter W Kurtz,Annsley Mace,Charley M Goodwin et al.
Peter W Kurtz et al.
As dual mobility hips become more popular, there is a clinical need to investigate design features that will impact tribocorrosion of these devices. While previous studies have investigated both corrosion and wear damage, the effect of devi...
The Importance of Modeling Press-Fit to Accurately Evaluate Interfacial Micromotion as an Indicator of Primary Stability in Uncemented Arthroplasty [0.03%]
模拟过盈配合以准确评估未使用骨水泥型关节置换假体界面微动作为初步稳定性指标的重要性
Joshua E Johnson,Nico Verdonschot,Dennis Janssen et al.
Joshua E Johnson et al.
Arthroplasty is most often performed to alleviate pain and restore function in patients with end-stage degenerative joint disease. Uncemented implant fixation is increasingly used in total knee and total ankle arthroplasty. Implantation usi...
Comparing Direct Anterior Approach Versus Posterolateral Approach in Total Hip Arthroplasty on Physical Function Recovery: A Prospective Cohort Study [0.03%]
一项有关全髋关节置换术中直接前侧入路与后外侧入路对物理功能恢复影响的前瞻性队列研究比较
Jesse C Christensen,Dana L Judd,Jeri E Forster et al.
Jesse C Christensen et al.
Total hip arthroplasty (THA) is estimated to exceed 500,000 procedures annually in the United States. Often after THA, deficits observed range from poor physical performance, muscle weakness and joint mechanics compensation, negatively impa...
Preserving Patient-Specific Knee Motion: A Randomized Clinical Trial of Unicompartmental and Total Knee Arthroplasty [0.03%]
preservation of patient-specific knee motion: a randomized clinical trial comparing unicompartmental and total knee arthroplasty
Gregor Kuntze,Sobhan Panjavi,Evonne Henning et al.
Gregor Kuntze et al.
Unicompartmental knee arthroplasty (UKA) may enable improved functional outcomes compared to total knee arthroplasty (TKA). This randomized controlled trial assessed pre- and postoperative patient reported outcome measures (PROMs) and knee ...
Corrosion in Modular Revision Hip Stem Tapers - A Retrieval Analysis [0.03%]
modular假体股骨柄锥形部分腐蚀的翻修分析
Therese Bormann,Haolan Yan,Sebastian Jaeger et al.
Therese Bormann et al.
In revision hip arthroplasty, modular stems enable intraoperative adjustment of the biomechanics of the hip to ensure a stable joint function even in complex anatomical cases. Modular stem junctions, however, carry the risk of junction degr...
Corrosion in Modular Revision Hip Stem Tapers - A Retrieval Analysis [0.03%]
modular假体柄锥形表面腐蚀问题及再处理分析
Therese Bormann,Haolan Yan,Sebastian Jaeger et al.
Therese Bormann et al.
In revision hip arthroplasty, modular stems enable intraoperative adjustment of the biomechanics of the hip to ensure a stable joint function even in complex anatomical cases. Modular stem junctions, however, carry the risk of junction degr...
Assessing Implant Stability in Cementless Femoral Components With Different Interference Fits [0.03%]
不同干扰配合的骨水泥型股骨假体稳定性评估
Esther Sánchez,Christoph Schilling,Thomas M Grupp et al.
Esther Sánchez et al.
Cementless total knee arthroplasty implants offer advantages over cemented implants, such as bone preservation and easier revision procedures. However, the optimal interference fit required to achieve a good press-fit fixation, essential fo...
Assessing Implant Stability in Cementless Femoral Components With Different Interference Fits [0.03%]
不同干扰配合下的骨水泥型股骨假体稳定性评估
Esther Sánchez,Christoph Schilling,Thomas M Grupp et al.
Esther Sánchez et al.
Cementless total knee arthroplasty implants offer advantages over cemented implants, such as bone preservation and easier revision procedures. However, the optimal interference fit required to achieve a good press-fit fixation, essential fo...