Mid-term Outcomes of Four-Fenestrated Endovascular Aneurysm Repair Without Stenting of the Celiac Artery (The UNCAP Study): Insights From a Multicentric European Experience [0.03%]
未释放肠系膜动脉球囊的四开窗覆膜支架修复腹主动脉瘤的中期结果(UNCAP研究):欧洲多中心研究经验分享
Pablo Marques de Marino,Mario DOria,Athanasios Katsargyris et al.
Pablo Marques de Marino et al.
Objectives: This study analyses the results of endovascular treatment of juxtarenal and suprarenal aortic aneurysms (J/SAAAs) using fenestrated stent-grafts with 4 fenestrations (4×FEVAR) in which the celiac artery (CA) ...
Trans-Sheath Thrombin Injection to Achieve Hemostasis During Increased Bore Retrograde Accesses [0.03%]
经皮血管腔内手术中应用涂抹凝血酶的球囊止血技术
Marta Lobato,August Ysa,Amaia Arruabarrena et al.
Marta Lobato et al.
Purpose: To describe a novel technique for achieving reliable hemostasis after retrograde popliteal or proximal below-the-knee (BTK) arterial access, particularly in larger-profile interventions, through trans-sheath inje...
Asymptomatic Spontaneous Extrusion of a Carotid Artery Stent 2 Months Post-Placement in a Radiated Neck [0.03%]
放射颈部置入颈动脉支架2个月后无症状自发行出1例报告
Minori Saito,Mio Kasai,Yutaro Aoyagi et al.
Minori Saito et al.
Background: Carotid blowout syndrome (CBS) is a rare but potentially fatal complication of head and neck cancer (HNC), with radiotherapy being a major risk factor. Because of its high mortality, urgent treatment is essent...
'Piercing the Ring': Percutaneous Needle-Assisted Technique for Unyielding Arteriovenous Fistula Venous Stenosis [0.03%]
“破茧成丝”经皮穿刺辅助技术治疗动静脉内瘘吻合口难治性静脉狭窄
Shuvro H Roy Choudhury,Anadi Gupta,Sabharisundaravel Paulraj et al.
Shuvro H Roy Choudhury et al.
Purpose: The study aims to describe a novel ultrasound-guided needle fenestration technique as a bailout strategy for balloon-refractory venous stenoses in arteriovenous fistulae (AVFs). ...
Popliteal Artery Entrapment Syndrome: A Systematic Review of Contemporary Management and Outcome Reporting [0.03%]
腓动脉压迫综合征:当代诊治和预后报告的系统综述
Hong-Jie Cui,Ying-Feng Wu
Hong-Jie Cui
Background: Popliteal artery entrapment syndrome (PAES) is a rare cause of exertional leg ischemia, and contemporary evidence on treatment outcomes remains limited by small, heterogeneous observational studies. This syste...
The Short and Midterm Outcomes of Local Versus General Anesthesia for Non-Emergency Thoracic Endovascular Repair in Acute Type B Aortic Dissection [0.03%]
局部麻醉与全身麻醉在急性B型主动脉夹层非紧急胸主动脉腔内修复术的近期及中期疗效比较研究
Dong Zhang,Yahong Sun,Zhidong He et al.
Dong Zhang et al.
Objective: General anesthesia (GA) has consistently served as the predominant anesthesia modality in thoracic endovascular aortic repair (TEVAR). The objective of this retrospective study was to systematically evaluate an...
Overlapping Stents for Dissecting Intracranial Aneurysms: A Systematic Review With Single-Arm Meta-Analysis [0.03%]
用于治疗颅内动脉瘤的重叠支架置入术:系统性回顾及单组Meta分析
João Vitor Andrade Fernandes,Mariana Letícia De Bastos Maximiano,Kenzo Ogasawara Donato et al.
João Vitor Andrade Fernandes et al.
Purpose: To assess the safety, efficacy, and clinical outcomes of overlapping stent-assisted reconstruction for dissecting intracranial aneurysms (DIAs) through a systematic review and single-arm meta-analysis. ...
Development and Validation of a Deep Learning-Based Segmentation Method for Fenestration Marker and Graft Body Identification in Fenestrated Endovascular Aortic Repair [0.03%]
基于深度学习的分叉型主动脉覆膜支架内修复术移植物和开窗标记物分割方法的建立与验证
Polycronis P Akouris,Sangwook Kim,Arshia P Javidan et al.
Polycronis P Akouris et al.
Objective: To develop and validate a deep learning-based segmentation method for accurate identification of fenestration markers and graft body contours in intraoperative fluoroscopic images during fenestrated endovascula...
Inter-Center Radiation Variability in CO2-Guided EVAR: Lessons From the Zero Iodine Contrast Multicenter Prospective Study [0.03%]
无碘对比剂下CO2引导EVAR的多中心前瞻性研究对中心间辐射差异性的启示
Emiliano Chisci,Emanuele Ferrero,Michele Antonello et al.
Emiliano Chisci et al.
Introduction: Current diagnostic reference levels (DRLs) for endovascular aortic repair (EVAR), based on iodinated contrast media (ICM) protocols, range from 100 to 200 Gy·cm2. As CO2 is a negative contrast agent requiri...