Colby Shanafelt,Thomas G Middour,Rand Ibrahim et al.
Colby Shanafelt et al.
Introduction: Transvenous leads have been implicated in tricuspid valve (TV) dysfunction, but limited data are available regarding the effect of extracting leads across the TV on valve regurgitation. The aim of this study...
One-year outcomes of pulmonary vein isolation with a novel cryoballoon: Primary results of the FROZEN AF trial [0.03%]
新型冷冻球囊进行肺静脉隔离一年的效果:FROZEN AF试验的主要结果
Kenneth A Ellenbogen,Suneet Mittal,Niraj Varma et al.
Kenneth A Ellenbogen et al.
Introduction: Cryoablation therapy for pulmonary vein isolation (PVI) to treat paroxysmal atrial fibrillation (PAF) is well established. A novel 28 mm cryoballoon system designed to operate under low pressure to safely re...
Inappropriate ICD classification of ventricular fibrillation as sinus tachycardia. What is the etiology? [0.03%]
心室颤动的ICD分类不恰当归类为窦性心动过速。其病因是什么?
Rafat Mahmood,Anil K Gehi
Rafat Mahmood
Impact of artificial intelligence arrhythmia mapping on time to first ablation, procedure duration, and fluoroscopy use [0.03%]
人工智能心律失常建模对首次消融时间、手术时长和荧光透视使用的影响
Sutton R Fox,Avinash Toomu,Kelly Gu et al.
Sutton R Fox et al.
Introduction: Artificial intelligence (AI) ECG arrhythmia mapping provides arrhythmia source localization using 12-lead ECG data; whether this information impacts procedural efficiency is unknown. We performed a retrospec...
Paced QRS morphology mimicking complete left bundle branch block induced by right ventricular pacing is associated with pacing-induced cardiomyopathy [0.03%]
右心室起搏诱发的类似完全性左束支阻滞的QRS形态与起搏器诱导的心肌病有关
Shota Ikeda,Kazuo Sakamoto,Masafumi Sugawara et al.
Shota Ikeda et al.
Introduction: Right ventricular (RV) pacing sometimes causes left ventricular (LV) systolic dysfunction, also known as pacing-induced cardiomyopathy (PICM). However, the association between specifically paced QRS morpholo...
Observational Study
Journal of cardiovascular electrophysiology. 2024 May;35(5):906-915. DOI:10.1111/jce.16229 2024
Durable pulmonary vein isolation with optimized high-power and very high-power short-duration temperature-controlled ablation: A step-by-step guide [0.03%]
使用优化的高功率和超高功率短时程温度控制消融实现持久的肺静脉隔离:逐步指南
Tom J R De Potter,Benjamin De Becker,Mattias Duytschaever
Tom J R De Potter
Introduction: Through systematic scientific rigor, the CLOSE guided workflow was developed and has been shown to improve pulmonary vein isolation durability. However, this technique was developed at a time when using powe...
Reply: Optimal procedural selection for atrial fibrillation catheter ablation to minimize myocardial injury and inflammatory reaction [0.03%]
回复:选择最优的导管消融程序以最小化心肌损伤和炎症反应的房颤治疗方法
Miruna A Popa,Gabriele Hessling,Isabel Deisenhofer
Miruna A Popa
Nonclinical evaluation of chronic cardiac contractility modulation on 3D human engineered cardiac tissues [0.03%]
慢性心脏收缩性调制在三维人类工程心脏组织中的非临床评价
Tromondae K Feaster,Jourdan K Ewoldt,Anna Avila et al.
Tromondae K Feaster et al.
Introduction: Cardiac contractility modulation (CCM) is a medical device-based therapy delivering non-excitatory electrical stimulations to the heart to enhance cardiac function in heart failure (HF) patients. The lack of...
Comparison of novel intrinsic versus conventional antitachycardia pacing for ventricular tachycardia among implantable cardioverter-defibrillator recipients [0.03%]
新型内在与传统抗心动过速起搏治疗心室心动过速在植入式心律转复除颤器受者中的比较研究
Satoshi Yanagisawa,Yasuya Inden,Yuki Sato et al.
Satoshi Yanagisawa et al.
Introduction: Intrinsic antitachycardia pacing (iATP) is a novel automated antitachycardia pacing (ATP) that provides individual treatment to terminate ventricular tachycardia (VT). However, the clinical efficacy of iATP ...
Mehak Dhande,Sandeep K Jain
Mehak Dhande