Impact of Timing of Atrial Fibrillation Ablation on AF Recurrence and Clinical Outcomes in Patients With HFpEF and HFrEF [0.03%]
射血分数保留和降低的心衰患者房颤消融时机对房颤复发及临床结局的影响
Mahmoud Eisa,Hossam Elbenawi,Abhishek J Deshmukh et al.
Mahmoud Eisa et al.
Averaged Impedance Drop Estimates Conduction Gap During Pulmonary Vein Isolation in Atrial Fibrillation [0.03%]
心房颤动中肺静脉隔离期间传导间隙的平均阻抗下降估计值
Masahide Harada,Yuji Motoike,Yoshihiro Nomura et al.
Masahide Harada et al.
Background: EnSite X provides a module to filter oscillated generator impedance signals due to cardiac beating/respiration (averaged impedance drop, AID). TactiFlex ablation catheter Sensor Enabled (TFSE) is the latest pr...
Approval Lag for Ablation Catheters: A Comparative Analysis of Regulatory Timelines in the European Union, United States, and Japan [0.03%]
射频消融导管的注册审批时间分析:欧盟、美国和日本的对比研究
Gaku Oguri,Katsuhito Fujiu,Norihiko Takeda
Gaku Oguri
Introduction: Approval timelines for ablation catheters differ across major markets, potentially delaying clinical access. This study aimed to quantify approval lags for contemporary ablation catheters across the EU, the ...
Navigating the Lead Paradox: Successful Co-Implantation of Cardiac Contractility Modulation Device and a Micra Leadless Pacemaker [0.03%]
经导管心脏收缩力调制装置与Micra无导线起搏器联合植入的临床研究
Gabriele Pavani,Paolo Garrone,Gianpaolo Varalda et al.
Gabriele Pavani et al.
Background: Wild-type transthyretin cardiac amyloidosis (ATTRwt-CA) can lead to refractory heart failure. A "lead paradox" occurs when patients with a Micra leadless pacemaker require lead-based Cardiac Contractility Modu...
The Road to Hell Is Paved With Plugged Ports-Leadless EGM Findings and Their Potential Clinical Implications [0.03%]
道旁何物,堵塞之端口兮——无铅EGM发现及其潜在的临床意义
Maciej Dyrbuś,Anna Kurek,Joanna Machowicz et al.
Maciej Dyrbuś et al.
Pacemaker and ICD Programming Adherence With Evidence-Based Recommendations [0.03%]
起搏器和ICD的程序符合基于证据的建议
Alexander Smith,Matthew Ortman,John Andriulli et al.
Alexander Smith et al.
Introduction: Despite data-driven 2015 expert consensus statement (consensus) guidelines on recommended PPM and ICD parameters, patients often fall short of optimal device programing. The purpose of this retrospective, ob...
Symptomatic Deep Venous Thrombosis of the Upper Extremity Following Transvenous Lead Extraction, Data From EXTRACT Registry [0.03%]
经导管导线拔除术后上肢症状性深静脉血栓形成:来自EXTRACT登记处的数据
Michal Joniec,Joanna Stachanczyk,Syliwia Gladysz-Wanha et al.
Michal Joniec et al.
Background: Venous thrombosis occurring after TLE procedures is a fairly common but poorly described complication and requires further investigation into its causes. ...
Prognostic Impact of Early Recurrence Following Pulsed Field Ablation: A Meta-Analysis [0.03%]
脉冲电场消融后早期复发的预后影响:一项 meta 分析
Esteban Arevalo,Cesar Erazo,Frans Serpa et al.
Esteban Arevalo et al.
Introduction: The conventional 3-month blanking period after atrial fibrillation (AF) ablation has been applied irrespective of energy modality. Pulsed field ablation (PFA), a nonthermal technique, may elicit different ti...
A Simple Method Is Used to Identify PVI-Responsive Patients With Persistent Atrial Fibrillation: Electrical Cardioversion and Noninduction Before Procedure [0.03%]
一种简单的识别持续性房颤导管消融PVI反应性的方法:电复律加术前非诱发试验
Hai-Yang Xie,Yuyang Chen,Yong Xie et al.
Hai-Yang Xie et al.
Background: Pulmonary vein isolation (PVI) demonstrates less efficacy in persistent atrial fibrillation (PersAF) compared to paroxysmal AF. Although recent multiple-center RCTs have shown that additional ablation, except ...