Left atrial appendage closure device outcomes among cirrhosis patients with atrial fibrillation: a United States National Cohort Study [0.03%]
肝病合并房颤患者的左心耳封堵结局:一项美国全国队列研究
Tanveer Mir,Wasiq F Rawasia,Mohammed Uddin et al.
Tanveer Mir et al.
Aims: Literature regarding outcomes associated with atrial fibrillation among cirrhosis patients who had left atrial appendage occlusion (LAAO) device procedure is limited. We aim to evaluate the in-hospital clinical outc...
Successful cardiac sympathetic denervation for Andersen-Tawil syndrome [0.03%]
安德森-塔威尔综合征患者成功接受心脏交感神经阻滞术
Michalina Krych,Kamila Janisz,Jarosław Kuriata et al.
Michalina Krych et al.
Clinical utility of the 4S-AF scheme in predicting progression of atrial fibrillation: data from the RACE V study [0.03%]
4S-AF评分方案预测房颤进展的临床价值:RACE V研究数据
Vicente Artola Arita,Martijn E Van De Lande,Neda Khalilian Ekrami et al.
Vicente Artola Arita et al.
Aims: The recent 4S-AF (scheme proposed by the 2020 ESC AF guidelines to address stroke risk, symptom severity, severity of AF burden and substrate of AF to provide a structured phenotyping of AF patients in clinical prac...
Treatment of frequent premature ventricular contractions via a single very high-power short-duration application [0.03%]
单次高强度短时间治疗频发室早的疗效及安全性研究
Christian-Hendrik Heeger,Roman Mamaev,Charlotte Eitel et al.
Christian-Hendrik Heeger et al.
Transient loss of capture after pulse field ablation due to pacing threshold elevation [0.03%]
脉冲场消融后由于起搏阈值升高导致捕获丢失
Philippe Maury,Anne Rollin,Franck Mandel
Philippe Maury
Magnetic resonance assessment of left atrial scar formation following a novel very high-power short-duration workflow for atrial fibrillation ablation [0.03%]
用于房颤消融的新式高功率短时间流程评估左心房疤痕形成磁共振评价
Vanessa Sciacca,Thomas Fink,Hermann Körperich et al.
Vanessa Sciacca et al.
Aims: Atrial fibrillation (AF) ablation protocols using energy delivery with very high power and short duration (vHPSD) have been introduced to improve lesion formation. This study reports procedural data of vHPSD ablatio...
Till F Althoff
Till F Althoff
Prevalence of asystole during tilt test-induced vasovagal syncope may depend on test methodology [0.03%]
倾斜台试验诱发血管迷走性晕厥时出现停博的比例可能与试验方法有关
Vincenzo Russo,Erika Parente,Antonella Groppelli et al.
Vincenzo Russo et al.
This review addresses tilt-testing methodology by searching the literature which reports timing of asystole and loss of consciousness (LOC). Despite the Italian protocol being the most widely adopted, its stipulations are not always followe...
Preclinical assessment of the feasibility, safety and lesion durability of a novel 'single-shot' pulsed field ablation catheter for pulmonary vein isolation [0.03%]
新型单次脉冲消融导管行肺静脉隔离的疗效、安全性和损伤持久性的一项临床前研究评估
Jacob Koruth,Iwanari Kawamura,Srinivas R Dukkipati et al.
Jacob Koruth et al.
Aims: Single-shot pulmonary vein isolation can improve procedural efficiency. To assess the capability of a novel, expandable lattice-shaped catheter to rapidly isolate thoracic veins using pulsed field ablation (PFA) in ...
Mapping-guided atrial lead placement determines optimal conduction across Bachmann's bundle: a rationale for patient-tailored pacing therapy [0.03%]
基于图谱的房内起搏导线定位指导bachmann束起搏治疗:个体化心脏再同步治疗新策略的理论依据
Mathijs S van Schie,Nawin L Ramdat Misier,Paul Knops et al.
Mathijs S van Schie et al.
Aims: Conventional right atrial appendage (RAA) pacing is associated with increased atrial activation time resulting in higher incidences of atrial tachyarrhythmia. Optimal pacing sites ideally shorten inter-atrial conduc...