Angelo Auricchio
Angelo Auricchio
Influence of stressful life events and personality traits on PLN cardiomyopathy severity: an exploratory study [0.03%]
生活压力事件和性格特征对PLN心肌病严重程度的影响:探索性研究
E van Drie,S E L Taal,A F Schmidt et al.
E van Drie et al.
Arrhythmias including atrial fibrillation and congenital heart disease in Kleefstra syndrome: a possible epigenetic link [0.03%]
Kleefstra综合征中的心律失常,包括心房纤颤和先天性心脏病:可能的表观遗传关联
Sunil K Vasireddi,Tanja Zdolsek Draksler,Arianne Bouman et al.
Sunil K Vasireddi et al.
Aims: Kleefstra syndrome (KS), often diagnosed in early childhood, is a rare genetic disorder due to haploinsufficiency of EHMT1 and is characterized by neuromuscular and intellectual developmental abnormalities. Although...
Up-regulated small-conductance calcium-activated potassium currents contribute to atrial arrhythmogenesis in high-fat feeding mice [0.03%]
高脂肪喂养小鼠中上调的小电导钙激活钾电流促进心房心律失常的形成
Wei-Chung Tsai,Yi-Hsiung Lin,Chia-Hao Kuo et al.
Wei-Chung Tsai et al.
Aims: Metabolic syndrome (MetS) is associated with arrhythmias and cardiovascular mortality. Arrhythmogenesis in MetS results from atrial structural and electrical remodelling. The small-conductance Ca2+-activated K+ (SK)...
Performance and safety of temperature- and flow-controlled radiofrequency ablation for ventricular arrhythmia [0.03%]
室性心律失常行温度控制和血流调节射频消融的疗效及安全性研究
Richard Kobza,Gabriela Hilfiker,Sophie Rissotto et al.
Richard Kobza et al.
Aims: High-power ablation is effective for ventricular arrhythmia ablation; however, it increases the risk of steam pops. The aim of this study was to define the safety and efficacy of QMODE ablation in the ventricle and ...
Cardiac radiotherapy transiently alters left ventricular electrical properties and induces cardiomyocyte-specific ventricular substrate changes in heart failure [0.03%]
心脏放射治疗会暂时改变左心室的电生理特性并诱发心力衰竭时心肌细胞特异性的室性基质变化
Felix Mehrhof,Judith Hüttemeister,Radu Tanacli et al.
Felix Mehrhof et al.
Aims: Ongoing clinical trials investigate the therapeutic value of stereotactic cardiac radioablation (cRA) in heart failure patients with ventricular tachycardia. Animal data indicate an effect on local cardiac conductio...
A cross-sectional nationwide survey of guideline based syncope units in the Netherlands: the SU-19 score-a novel validation for best practices [0.03%]
荷兰全国基于指南的晕厥单元的横断面调查:SU-19评分-最佳实践的新验证
Steven van Zanten,Jelle S Y de Jong,Mike G Scheffer et al.
Steven van Zanten et al.
Aims: We aimed to identify all syncope units (SUs) in the Netherlands and assess the extent to which these SUs fulfil the essential requirements outlined by the consensus statements of the European Heart Rhythm Associatio...
Electrophysiological characteristics and ablation of ventricular arrhythmias originating from the intramural basal inferior septum [0.03%]
起源于室间隔基底部的室性心律失常的电生理特性及消融术
Jie Yang,Mengmeng Li,Chenxi Jiang et al.
Jie Yang et al.
Aims: The electrocardiographic and electrophysiological characteristics of ventricular arrhythmia (VA) arising from the intramural basal inferior septum (BIS) have not been specifically addressed to date. The aim of the c...
Severe acute kidney injury related to haemolysis after pulsed field ablation for atrial fibrillation [0.03%]
与房颤脉冲场消融后溶血相关的严重急性肾损伤
Sandrine Venier,Nathan Vaxelaire,Peggy Jacon et al.
Sandrine Venier et al.
Aims: Pulsed field ablation (PFA) has been proposed as a novel alternative to radiofrequency (RF) and cryoablation in the treatment of atrial fibrillation (AF). Following the occurrence of two cases of acute kidney injury...
Improved diagnostic performance of insertable cardiac monitors by an artificial intelligence-based algorithm [0.03%]
基于人工智能算法的心脏植入式监测器的改进诊断性能
Eliot Crespin,Arnaud Rosier,Issam Ibnouhsein et al.
Eliot Crespin et al.
Aims: The increasing use of insertable cardiac monitors (ICM) produces a high rate of false positive (FP) diagnoses. Their verification results in a high workload for caregivers. We evaluated the performance of an artific...