Photoplethysmography based remote cardiac blood pressure monitoring compared with 24-h ambulatory blood pressure monitoring [0.03%]
基于PPG的远程心脏血压监测与24小时动态血压监测的比较研究
Mariska van Vliet,Jan J J Aalberts,Cora Hamelinck et al.
Mariska van Vliet et al.
Objective: To evaluate the accuracy of a novel wrist-worn cuff-calibrated photoplethysmography (PPG)-based remote patient monitoring device as an alternative to ambulatory blood pressure monitoring (ABPM). ...
Validating the accuracy of the YuWell YE680B automated upper-arm blood pressure monitor in pediatric and adult populations according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (ISO 81060-2:2018/Amd.1:2020/Amd.2:2024) [0.03%]
根据医疗器械促进协会/欧洲高血压学会/国际标准化组织标准,对YuWell YE680B全自动上臂血压计在儿童和成人中的准确性验证
Feng Liang,Bingbing Zhang,Chi Yuan et al.
Feng Liang et al.
Accurate blood pressure (BP) measurement is essential for hypertension management. Automated oscillometric BP monitors must be validated according to international standards before clinical and home use. This study aimed to evaluate the acc...
The effects of aerobic training on ambulatory blood pressure, blood pressure variability, and arterial stiffness in postmenopausal women with and without multimorbidity: a preliminary study [0.03%]
有合并症绝经期女性的有氧运动对血压、血压变异性和动脉僵硬度的影响:初步研究
Juliene G Costa,Ana Luiza Amaral,Caroline P Garcês et al.
Juliene G Costa et al.
Background: Multimorbidity represents significant public health challenges, particularly in postmenopausal women, who experience increased risks for cardiovascular and metabolic diseases because of hormonal changes. While...
Clinical evaluation of the Wellvii BP Go blood pressure monitor according to the International Standardization Organization 81060-2:2018 [0.03%]
根据国际标准化组织ISO 81060-2:2018对Welvii BP Go血压计的临床评价
Jialiang Ma,Yao Xiao,Yage Wang et al.
Jialiang Ma et al.
Objective: This study aimed to evaluate the accuracy of the Wellvii BP Go automated oscillometric finger blood pressure (BP) monitor for self/home BP measurement according to the International Standardization Organization...
Blood pressure measurement using a wide-range conical cuff from 22 to 45 cm of arm circumference: validation of the Prolife PX7 Premium, an upper-arm blood pressure monitor with Inflation Mode Technology evaluated in a general population according to the ISO 81060-2:2018 + Amd1:2020/Amd2:2024 protocol [0.03%]
用于臂围22至45厘米的宽范围圆锥袖带测量血压:根据ISO 81060-2:2018+Amd1:2020/Amd2:2024协议在普通人群中验证Prolife PX7 Premium上臂血压计的Inflation Mode Technology
Claudio Fania,Elena Meggiolaro,Debora De Franceschi et al.
Claudio Fania et al.
The aim of the study was to determine the accuracy of the Prolife PX7 Premium monitor for upper arm blood pressure (BP) measurement according to the International Organization for Standardization (ISO) 81060-2:2018/Amd1:2020/Amd2:2024 proto...
Validation of the Omron HEM-7380T (HCR-7728T) blood pressure monitor in the general population according to the international organization for standardization 81060-2:2018 + Amd.1:2020 and Amd.2:2024 [0.03%]
欧姆龙HEM-7380T(HCR-7728T)血压计在一般人群中按照ISO 81060-2:2018 + CL.1:2020和CL.2:2024国际组织标准进行验证
Hakuo Takahashi,Nobuki Yakura,Mitsuo Kuwabara
Hakuo Takahashi
Objective: This study aimed to validate the accuracy of Omron HEM-7380T (HCR-7728T), an automated deflationary oscillometric upper-arm blood pressure (BP) monitor, according to the international organization for standardi...
Testing the accuracy of blood pressure measuring devices: challenges and pitfalls of validation studies [0.03%]
血压测量装置准确度的检测:验证研究中的挑战及陷阱
Paolo Palatini
Paolo Palatini
Several protocols have been devised for the validation of blood pressure (BP) measurement monitors to establish minimum standards of accuracy. Three aspects are crucial for improving the agreement between the device and the reference BP whi...
Three cases of hypertension-related events who were not treated as 'white-coat hypertension' [0.03%]
三例未被诊断为"白大衣高血压"的与高血压相关的事件
Kazuo Eguchi,Yasuhiro Takahashi,Manabu Nakamura et al.
Kazuo Eguchi et al.
Validation of the B.Well TH-75 oscillometric upper-arm blood pressure monitor in general population according to the AAMI/ESH/ISO universal standard (ISO 81060-2:2018+Amd1:2020+Amd2:2024) [0.03%]
根据AAMI/ESH/ISO通用标准(ISO 81060-2:2018+Amd1:2020+Amd2:2024)在普通人群中验证B.Well TH-75上臂式电子血压计的准确性
Yage Wang,Jialiang Ma,Yang Zhang et al.
Yage Wang et al.
Objective: The aim of this study was to evaluate the accuracy of the B.Well TH-75 oscillometric upper-arm blood pressure (BP) monitor in general population according to the AAMI/ESH/ISO universal standard (ISO 81060-2 : 2...
Accuracy of atrial fibrillation detection using Hanvon Korotkoff sound blood pressure monitor [0.03%]
汉 Von Korotkoff 声音血压计检测房颤的准确性
Jian Wang,Yingjian Liu,Chongjie Chen
Jian Wang
Background: Atrial fibrillation is one of the most common cardiac arrhythmias. It is a condition that significantly increases the risk of stroke and cardiac complications, making its early diagnosis and intervention a cru...