Artificial intelligence-based assessment of leg axis parameters shows excellent agreement with human raters: A systematic review and meta-analysis [0.03%]
基于人工智能的下肢力线参数评估与人工评价高度一致:系统回顾和元分析
Mikhail Salzmann,Hakam Hassan Tarek,Robert Prill et al.
Mikhail Salzmann et al.
Purpose: The aim of this study was to conduct a systematic review and meta-analysis on the reliability and applicability of artificial intelligence (AI)-based analysis of leg axis parameters. We hypothesized that AI-based...
Comparative study of two different horizontal stabilisation methods in arthroscopically assisted coracoclavicular stabilisation for acute acromioclavicular joint dislocations-Good clinical outcome and no correlation to recurrent anteroposterior instability [0.03%]
两种不同的肩锁关节外侧复合体水平稳定技术治疗急性肩锁关节脱位的初步比较研究:良好的临床疗效及与再发前后向不稳无关性
Michael Kimmeyer,Katharina Rapp,Verena Rentschler et al.
Michael Kimmeyer et al.
Purpose: The hypothesis of this study was that acromioclavicular K-wire transfixation is noninferior to horizontal FiberTape cerclage in terms of vertical and horizontal stability in the short follow-up period of acute ac...
Preoperative subjective assessment of disease-specific quality of life significantly influenced the likelihood of achieving the minimal clinically important difference after surgical stabilization for recurrent lateral patellar instability [0.03%]
术前主观评估疾病特异性生活质量对复发性膝外侧不稳定的外科治疗后达到最小临床重要差异的影响较大
Danko Dan Milinkovic,Sebastian Schmidt,Julian Fluegel et al.
Danko Dan Milinkovic et al.
Purpose: To evaluate which factors exert a predictive value for not reaching the minimal clinically important difference (MCID) in patients who underwent a tailored operative treatment for recurrent lateral patellar dislo...
The modified Nice knot has improved mechanical performance compared to the cinch stitch for meniscal root repair [0.03%]
改良的Nice结与cinch缝合法在半月板根部修复中的应用效果较好
João Pedro Oliveira,José António Simões,José Carlos Noronha et al.
João Pedro Oliveira et al.
Purpose: According to previous biomechanical studies, the success of meniscus root repair depends on the suture-meniscus interface and optimisation of this procedure seems to be critical. A progressive, reliable and adjus...
Arthroscopic anterior deltoid plication with bone anchor is an effective procedure to control residual talar anterior translation after lateral ligament repair [0.03%]
关节镜下前距骨止点重建术可有效控制外侧韧带修复术后残留的距骨过度向前进滑现象
Jordi Vega,Francesc Malagelada,Matteo Guelfi et al.
Jordi Vega et al.
Purpose: Residual symptoms can be observed after ankle lateral ligament repairs commonly due to hyperlaxity, severe ankle instability or a failed stabilization. In order to increase joint stability, ligament or capsular-l...
Minimal effect of scanning parameters on ultrasound shear wave elastography variability in tendons [0.03%]
声脉冲辐射力弹性成像检测肌腱的重复性不受扫查参数影响
Jennifer A Zellers,Ran Li,Rachana Vaidya et al.
Jennifer A Zellers et al.
Purpose: Ultrasound shear wave elastography has potential use in assessing tendon tissue; however, reducing measurement variability remains challenging. The primary purpose of this study was to identify the amount of vari...
Long-term clinical and radiological outcomes after arthroscopic partial meniscectomy on stable knees are better for traumatic tears when compared to degenerative lesions: A systematic review [0.03%]
系统评价:与退变性半月板病变相比,对于稳定膝关节的创伤性半月板囊肿行镜手术部分切除术后的长期临床和放射学结局更好
Héloïse Bogas Droy,Théopol Dardenne,Azeddine Djebara et al.
Héloïse Bogas Droy et al.
Purpose: An arthroscopic partial meniscectomy (APM) for degenerative meniscus lesions and traumatic meniscus tears are two distinct entities and their long-term outcomes are rarely reported. The aim of this review was to ...
Valgus stress knee radiographs accurately anticipate the bone resection in medial unicompartmental knee arthroplasty: Protocol validation using an image-based robotic system [0.03%]
内侧单间室膝关节置换术骨切除的影像机器人系统验证:基于应力X线片的方案有效性研究
Stefano Gaggiotti,Constant Foissey,Valentina Rossi et al.
Stefano Gaggiotti et al.
Purpose: The objective of this study was to describe a planning method for medial unicompartmental knee arthroplasty (UKA) implantation using preoperative stress radiographs to measure the thickness of tibial and femoral ...
Intraoperative lateral laxity greater than 4° is associated with inferior functional improvement in posterior-stabilised total knee arthroplasty [0.03%]
后稳定型膝关节置换术中侧向松弛度大于4°与功能改善不佳有关
Takao Inokuchi,Hirotsugu Muratsu,Tomoyuki Kamenaga et al.
Takao Inokuchi et al.
Purpose: The study aimed to determine the impact of intraoperative lateral laxity at extension on clinical and functional outcomes 1 year after posterior-stabilised total knee arthroplasty (PS-TKA). ...
Trends and epidemiology in robotic-assisted total knee arthroplasty: Reduced complications and shorter hospital stays [0.03%]
机器人辅助全膝关节置换术的趋势和流行病学:减少并发症和缩短住院时间
David Maman,Lior Laver,Roland Becker et al.
David Maman et al.
Introduction: This study provides an in-depth analysis of the immediate postoperative outcomes and implications or robotic-assisted total knee arthroplasty (RA-TKA) compared with conventional TKA (C-TKA), particularly wit...