Drug diffusion and biological responses of arteries using a drug-eluting stent with nonuniform coating [0.03%]
非均匀涂层药物洗脱支架的药物扩散及动脉组织的生物学反应研究
Noboru Saito,Yuhei Mori,Sayaka Uchiyama
Noboru Saito
The purpose of this study was to determine the effect of a nonuniform coating, abluminal-gradient coating (AGC), which leaves the abluminal surface of the curves and links parts of the stent free from the drug coating, on the diffusion dire...
Clinical effectiveness and safety of powered exoskeleton-assisted walking in patients with spinal cord injury: systematic review with meta-analysis [0.03%]
电动外骨骼辅助脊髓损伤患者行走的临床有效性及安全性:系统综述与元分析
Larry E Miller,Angela K Zimmermann,William G Herbert
Larry E Miller
Background: Powered exoskeletons are designed to safely facilitate ambulation in patients with spinal cord injury (SCI). We conducted the first meta-analysis of the available published research on the clinical effectivene...
Wanan Yang,Houde Dai,Yong He et al.
Wanan Yang et al.
Wireless capsule endoscope achieved great success, however, the maneuvering of wireless capsule endoscope is challenging at present. A magnetic driving instrument, including two bar magnets, a stepper motor, a motor driver, a motor controll...
Cardiac resynchronization therapy pacemaker: critical appraisal of the adaptive CRT-P device [0.03%]
可适应性心脏再同步治疗起搏器的批判性评估
Georges E Daoud,Mahmoud Houmsse
Georges E Daoud
Cardiac resynchronization therapy (CRT) is an effective and well-established therapy for patients suffering with heart failure, left ventricular (LV) systolic dysfunction (ejection fraction ≤35%), and electrical dyssynchrony, demonstrated ...
Jacob Hyllested-Winge,Thomas Sparre,Line Kynemund Pedersen
Jacob Hyllested-Winge
The introduction of insulin pen devices has provided easier, well-tolerated, and more convenient treatment regimens for patients with diabetes mellitus. When compared with vial and syringe regimens, insulin pens offer a greater clinical eff...
Control of bleeding in surgical procedures: critical appraisal of HEMOPATCH (Sealing Hemostat) [0.03%]
手术止血中的应用——关于HEMOPATCH(止血材料)的评价研究
Kevin Michael Lewis,Carl Erik Kuntze,Heinz Gulle
Kevin Michael Lewis
The need for advanced hemostatic agents increases with the complexity of surgical procedures and use of anticoagulation and antiplatelet treatments. HEMOPATCH (Sealing Hemostat) is a novel, advanced hemostatic pad that is composed of a synt...
Novel treatment options for nonmelanoma skin cancer: focus on electronic brachytherapy [0.03%]
非黑色素瘤皮肤癌的新型治疗选择:以电子近距离放射治疗为重点
Michael E Kasper,Ahmed A Chaudhary
Michael E Kasper
Nonmelanoma skin cancer (NMSC) is an increasing health care issue in the United States, significantly affecting quality of life and impacting health care costs. Radiotherapy has a long history in the treatment of NMSC. Shortly after the dis...
Implant survivorship analysis after minimally invasive sacroiliac joint fusion using the iFuse Implant System(®) [0.03%]
采用iFuse植入系统进行微创骶髂关节融合术后的植骨存活分析
Daniel J Cher,W Carlton Reckling,Robyn A Capobianco
Daniel J Cher
Introduction: Surgical revision rate is a key outcome with all permanent implants. The iFuse Implant System(®) is a permanent implant used to perform minimally invasive sacroiliac joint fusion. The purpose of this study ...
Evaluation of the impact of viscosity, injection volume, and injection flow rate on subcutaneous injection tolerance [0.03%]
评估黏度、注射量和注射流速对皮下注射耐受性的影响
Cecile Berteau,Orchidée Filipe-Santos,Tao Wang et al.
Cecile Berteau et al.
Aim: The primary objective of this study was to evaluate the impact of fluid injection viscosity in combination with different injection volumes and flow rates on subcutaneous (SC) injection pain tolerance. ...
Validation of pressure gradient and peripheral fractional flow reserve measured by a pressure wire for diagnosis of iliofemoral artery disease with intermediate stenosis [0.03%]
血管阻力梯度和压力导丝测量的外周血流储备分数诊断髂股动脉中间段狭窄疾病的验证研究
Naotaka Murata,Hideaki Aihara,Yoshimitsu Soga et al.
Naotaka Murata et al.
Objective: To examine the pressure gradient and peripheral fractional flow reserve (pFFR) measured by a pressure wire as indicators of hemodynamic significance in iliofemoral angiographic intermediate stenosis. ...