M A Ritter,L E Eizember,R Fechtman et al.
M A Ritter et al.
Porous-surfaced femoral components were approved by the United States Food and Drug Administration for implantation with polymethyl methacrylate cement in total hip arthroplasty. The ability of porous coating to prevent loosening of prosthe...
Comparative Study
Seminars in arthroplasty. 1990 Jul;1(1):16-21. DOI: 1990
Long-term follow-up of the Indiana conservative resurfacing hip arthroplasty [0.03%]
Indiana保守性表面置换髋关节置换的长期随访研究
P M Faris,M A Ritter,R Bicknell et al.
P M Faris et al.
Sixty-four Indiana conservative (Depuy, Warsaw, IN) hip arthroplasties performed in 61 patients were reviewed for loosening, mechanisms of loosening, and revision rate. Mean follow-up time was 6.8 years. There were revisions in 26 hips (40....
M A Ritter,E M Keating,P M Faris
M A Ritter
A Kaplan-Meier survival analysis of 240 Charnley, 149 Mueller (Depuy, Warsaw, IN), 576 Trapezoidal 28 (Zimmer, Warsaw, IN), and 100 Miami Orthopaedic Surgical Clinics (Biomet, Warsaw, IN) cemented total hip replacements with all polyethylen...
Comparative Study
Seminars in arthroplasty. 1990 Jul;1(1):7-11. DOI: 1990
Long-term survival of the Charnley low-friction total hip arthroplasty [0.03%]
减少摩擦的Charnley髋关节置换术的长期存活率分析
W J Hozack,R H Rothman
W J Hozack
A survivorship analysis of 1,151 Charnley low-friction total hip arthroplasties performed as a primary procedure showed the following 15-year failure probabilities: hip revision 13%, cup revision 8%, femoral revision 12%, radiographic femor...
S A Stuchin
S A Stuchin
Revision, and complicated primary total knee arthroplasty (TKA), may present with significant structural bony defects. Allograft offers blocks of material that can be shaped to the defect. The opportunity to gain a biological bond may theor...
The use of cortical allograft struts for fixation of fractures associated with well-fixed total joint prostheses [0.03%]
同种异体皮质骨移植物棒在固定与牢固的关节置换假体相关的骨折中的应用
H P Chandler,D King,R Limbird et al.
H P Chandler et al.
Nineteen patients with 19 fractures around or below a well-fixed femoral stem, were treated by open reduction and internal fixation using massive cortical allograft struts and cerclage wires or cables. The first procedure was performed in 1...
W C Head,J M Hillyard,R H Emerson Jr et al.
W C Head et al.
The senior authors have performed 141 proximal femoral whole-bone allografts in failed total hip reconstruction. The results of the first 50 have been previously reported. This study reviews 70 additional cases performed since 1987 and refl...
Acetabular revision with the bipolar prosthesis and particulate bone grafting [0.03%]
双极假体和骨水泥用于髋关节翻修手术中的颗粒骨移植
R Namba,R D Scott
R Namba
Acetabular revisions with bipolar prostheses and particulate bone grafting are seldom performed because of the clinical success of porous coated cementless acetabular components. When limited to cavitary defects and appropriate-sized implan...
C M McAllister,L S Borden
C M McAllister
Acetabular deficiencies seen in revision hip arthroplasty require special attention. Custom components, space-filling cement, relocation of the hip center higher on ilium, and resection arthroplasties have all been used. Allograft reconstru...
W J Hozack
W J Hozack
Acetabular reconstruction and revision can be a complex and demanding procedure. This article reviews the essential components of preoperative planning and surgical technique. In addition, there are several unsolved issues that will be addr...