首页 文献索引 SCI期刊 AI助手
期刊目录筛选

期刊名:Seminars in arthroplasty

缩写:

ISSN:1045-4527

e-ISSN:1558-4437

IF/分区:0.0/

文章目录 更多期刊信息

共收录本刊相关文章索引153
Clinical Trial Case Reports Meta-Analysis RCT Review Systematic Review
Classical Article Case Reports Clinical Study Clinical Trial Clinical Trial Protocol Comment Comparative Study Editorial Guideline Letter Meta-Analysis Multicenter Study Observational Study Randomized Controlled Trial Review Systematic Review
P F Sharkey,L R Wolf,E L Hume et al. P F Sharkey et al.
A Taperloc femoral component (Biomet Inc, Warsaw, IN) was implanted in seven fresh-frozen cadaver femora. In loads simulating single-leg stance and stair climbing, axial and rotational stability were tested before fracture, after fracture, ...
P F Sharkey,T J Albert,E L Hume et al. P F Sharkey et al.
A collarless wedge-shaped implant was inserted with cementless technique in seven fresh-frozen adult femora. Micromotion of the implant in the proximal femur was evaluated by applying an axial load of 3,000 N or a rotational force of 12 Nm....
L D Dorr,M Absatz,T A Gruen et al. L D Dorr et al.
One hundred consecutive Anatomic Porous Replacement (Intermedics Orthopaedics, Austin, TX) hip replacements were followed for 4 years. Eighty percent of patients had bone ingrowth fixation, 14% stable fibrous, and 6% unstable fibrous (loose...
T H Mallory,M B Mitchell T H Mallory
Successful cementless total hip arthroplasty is dependent on initial stabilization at the bone-prosthesis interface. Other factors, such as the adaptability of the prosthetic design to fit specific bony geometries, affect clinical outcome. ...
W J Hozack,R E Booth Jr W J Hozack
Eighty-one cementless Trilock (Depuy, Warsaw, IN) femoral components were observed for 2 to 6 years. The following end points were examined: revision (none), pain score less than 5 (six patients), and radiographic settling greater than 5 mm...
P M Faris,C H Kavolus,M A Ritter et al. P M Faris et al.
A radiographic examination of 91 uncemented hemispheric titanium alloy acetabular components and 85 straight-stemmed titanium alloy femoral components was performed. Analysis included zonal radionuclides, migration, bone changes, and fit. C...
J M McKenzie,C L Nelson,W W Goodman J M McKenzie
One hundred sixty-one porous-coated Universal (Biomet Inc, Warsaw, IN) total hip arthroplasties were performed and studied preoperatively between July 1986 and June 1989. The study included 59 men (38 at 1-year follow-up; 21 at 2-year follo...
E M Keating,R A Czarkowski,M A Ritter et al. E M Keating et al.
A radiographic analysis was done of 83 primary hip arthroplasties performed in 70 patients. The arthroplasty consisted of a truncated acetabular cup and a cemented titanium femoral stem. The patients were evaluated at an average of 3.3 year...
D A Fisher,T H Mallory,T J Kraus et al. D A Fisher et al.
Three hundred four cementless acetabular components: 54 Ceramic (Richards Medical Co, Memphis, TN); 33 T-Tap (Richards Medical Co); 22 MHP, (Biomet Inc, Warsaw, IN); 109 PCA (Howmedica, Rutherford, NJ), and 86 S-ROM SuperCup (Joint Medical ...
J A Shaw,A Bruno,R B Greer rd et al. J A Shaw et al.
A retrospective clinical and radiographic review of 140 primary total hip arthroplasties using a bipolar acetabular component and an uncemented AML femoral component (Depuy, Warsaw, IN) was done. The length of follow-up was from 2 to 5 year...