Insertional femoral fracture: a biomechanical study of femoral component stability [0.03%]
股骨插入性骨折:关于股骨部件稳定的生物力学研究
P F Sharkey,L R Wolf,E L Hume et al.
P F Sharkey et al.
A Taperloc femoral component (Biomet Inc, Warsaw, IN) was implanted in seven fresh-frozen cadaver femora. In loads simulating single-leg stance and stair climbing, axial and rotational stability were tested before fracture, after fracture, ...
Initial stability of a collarless wedge-shaped prosthesis in the femoral canal [0.03%]
无领楔形假体在股骨髓腔内的初步稳定性研究
P F Sharkey,T J Albert,E L Hume et al.
P F Sharkey et al.
A collarless wedge-shaped implant was inserted with cementless technique in seven fresh-frozen adult femora. Micromotion of the implant in the proximal femur was evaluated by applying an axial load of 3,000 N or a rotational force of 12 Nm....
Comparative Study
Seminars in arthroplasty. 1990 Jul;1(1):87-90. DOI: 1990
Anatomic Porous Replacement hip arthroplasty: first 100 consecutive cases [0.03%]
解剖学多孔型人工髋关节假体置换术的临床应用初步报告(附100例报告)
L D Dorr,M Absatz,T A Gruen et al.
L D Dorr et al.
One hundred consecutive Anatomic Porous Replacement (Intermedics Orthopaedics, Austin, TX) hip replacements were followed for 4 years. Eighty percent of patients had bone ingrowth fixation, 14% stable fibrous, and 6% unstable fibrous (loose...
T H Mallory,M B Mitchell
T H Mallory
Successful cementless total hip arthroplasty is dependent on initial stabilization at the bone-prosthesis interface. Other factors, such as the adaptability of the prosthetic design to fit specific bony geometries, affect clinical outcome. ...
Clinical and radiographic results with the Trilock femoral component--a wedge-fit porous ingrowth stem design [0.03%]
Trilock股骨组件的临床和放射学结果-一种楔形拟合多孔生长茎设计
W J Hozack,R E Booth Jr
W J Hozack
Eighty-one cementless Trilock (Depuy, Warsaw, IN) femoral components were observed for 2 to 6 years. The following end points were examined: revision (none), pain score less than 5 (six patients), and radiographic settling greater than 5 mm...
A radiographic analysis of a straight-stemmed uncemented femoral component and hemispheric porous-coated acetabular component in total hip arthroplasty [0.03%]
金属对聚乙烯髋关节置换的放射分析
P M Faris,C H Kavolus,M A Ritter et al.
P M Faris et al.
A radiographic examination of 91 uncemented hemispheric titanium alloy acetabular components and 85 straight-stemmed titanium alloy femoral components was performed. Analysis included zonal radionuclides, migration, bone changes, and fit. C...
Universal total hip replacement with focus on the acetabular component and the hybrid hip [0.03%]
以髋臼部件和混合型人工髋关节置换为重点的全髋关节置换术
J M McKenzie,C L Nelson,W W Goodman
J M McKenzie
One hundred sixty-one porous-coated Universal (Biomet Inc, Warsaw, IN) total hip arthroplasties were performed and studied preoperatively between July 1986 and June 1989. The study included 59 men (38 at 1-year follow-up; 21 at 2-year follo...
Comparative Study
Seminars in arthroplasty. 1990 Jul;1(1):50-6. DOI: 1990
E M Keating,R A Czarkowski,M A Ritter et al.
E M Keating et al.
A radiographic analysis was done of 83 primary hip arthroplasties performed in 70 patients. The arthroplasty consisted of a truncated acetabular cup and a cemented titanium femoral stem. The patients were evaluated at an average of 3.3 year...
Evaluation of the design and clinical performance of cementless acetabular components [0.03%]
无水泥髋臼假体的设计评价及其临床应用效果分析
D A Fisher,T H Mallory,T J Kraus et al.
D A Fisher et al.
Three hundred four cementless acetabular components: 54 Ceramic (Richards Medical Co, Memphis, TN); 33 T-Tap (Richards Medical Co); 22 MHP, (Biomet Inc, Warsaw, IN); 109 PCA (Howmedica, Rutherford, NJ), and 86 S-ROM SuperCup (Joint Medical ...
Comparative Study
Seminars in arthroplasty. 1990 Jul;1(1):35-44. DOI: 1990
J A Shaw,A Bruno,R B Greer rd et al.
J A Shaw et al.
A retrospective clinical and radiographic review of 140 primary total hip arthroplasties using a bipolar acetabular component and an uncemented AML femoral component (Depuy, Warsaw, IN) was done. The length of follow-up was from 2 to 5 year...