首页 文献索引 SCI期刊 AI助手
期刊目录筛选

期刊名:Sensors and actuators a-physical

缩写:SENSOR ACTUAT A-PHYS

ISSN:0924-4247

e-ISSN:1873-3069

IF/分区:5.1/Q1

文章目录 更多期刊信息

共收录本刊相关文章索引84
Clinical Trial Case Reports Meta-Analysis RCT Review Systematic Review
Classical Article Case Reports Clinical Study Clinical Trial Clinical Trial Protocol Comment Comparative Study Editorial Guideline Letter Meta-Analysis Multicenter Study Observational Study Randomized Controlled Trial Review Systematic Review
Ling-Sheng Jang,Shih-Hui Chao,Mark R Holl et al. Ling-Sheng Jang et al.
A common micromixer design strategy is to generate interleaved flow topologies to enhance diffusion. However, problems with these designs include complicated structures and dead volumes within the flow fields. We present an active micromixe...
D Homentcovschi,R N Miles D Homentcovschi
The paper gives an analytical approximation to the viscous damping coefficient due to the motion of a gas between a pair of closely spaced fluctuating plates in which one of the plates contains a regular system of circular holes. These type...
David A Horsley,Hyunkyu Park,Sophie P Laut et al. David A Horsley et al.
The static and dynamic characteristics of a bimorph deformable mirror (DM) for use in an adaptive optics system are described. The DM is a 35-actuator device composed of two disks of lead magnesium niobate (PMN), an electrostrictive ceramic...
R Bhandari,S Negi,L Rieth et al. R Bhandari et al.
A novel fabrication technique has been developed for creating high density (6.25 electrodes/mm(2)), out of plane, high aspect ratio silicon-based convoluted microelectrode arrays for neural and retinal prostheses. The convoluted shape of th...
Ren Yang,Steven A Soper,Wanjun Wang Ren Yang
This paper describes the design, microfabrication and testing of a pre-aligned array of fiber couplers using direct UV-lithography of SU-8. The fiber coupler array includes an out-of-plane refractive microlens array and two fiberport collim...
S Kim,K Zoschke,M Klein et al. S Kim et al.
Reliable chronic operation of implantable medical devices such as the Utah Electrode Array (UEA) for neural interface requires elimination of transcutaneous wire connections for signal processing, powering and communication of the device. A...
Guanxiong Li,Shouheng Sun,Robert J Wilson et al. Guanxiong Li et al.
We present giant magnetoresistance (GMR) spin valve sensors designed for detection of superparamagnetic nanoparticles as potential biomolecular labels in magnetic biodetection technology. We discuss the sensor design and experimentally demo...
J H Daniel,A Sawant,M Teepe et al. J H Daniel et al.
Megavoltage x-ray imaging performed during radiotherapy is the method of choice for geometric verification of patient localization and dose delivery. Presently, such imaging is increasingly performed using electronic portal imaging devices ...
Xuefeng Zhuang,Arif S Ergun,Yongli Huang et al. Xuefeng Zhuang et al.
This paper presents a method to provide electrical connection to a 2D capacitive micromachined ultrasonic transducer (CMUT) array. The interconnects are processed after the CMUTs are fabricated on the front side of a silicon wafer. Connecti...
Keat G Ong,Craig A Grimes Keat G Ong
This paper describes the application of magnetically-soft ribbon-like sensors for measurement of temperature and stress, as well as corrosive monitoring, based upon changes in the amplitudes of the higher-order harmonics generated by the se...