共收录本刊相关文章索引134
Clinical Trial Case Reports Meta-Analysis RCT Review Systematic Review
Classical Article Case Reports Clinical Study Clinical Trial Clinical Trial Protocol Comment Comparative Study Editorial Guideline Letter Meta-Analysis Multicenter Study Observational Study Randomized Controlled Trial Review Systematic Review
X Michalet,O H W Siegmund,J V Vallerga et al. X Michalet et al.
We have developed a photon-counting High-temporal and High-spatial resolution, High-throughput 3-Dimensional detector (H33D) for biological imaging of fluorescent samples. The design is based on a 25 mm diameter S20 photocathode followed by...
Jianguo Qian,Eric L Bradley,Stan Majewski et al. Jianguo Qian et al.
We have designed and built a small animal single photon emission computed tomography (SPECT) imaging system equipped with parallel-hole and multipinhole collimators and capable of circular or helical SPECT. Copper-beryllium parallel-hole co...
H Kim,C M Kao,Q Xie et al. H Kim et al.
As an approach to realizing all-digital data acquisition for positron emission tomography (PET), we have previously proposed and studied a multi-threshold sampling method to generate samples of a PET event waveform with respect to a few use...
Brian W Miller,Harrison H Barrett,Lars R Furenlid et al. Brian W Miller et al.
Recent advances have been made with the BazookaSPECT detector, a high-resolution CCD-based gamma camera which utilizes an MCP-based image intensifier for upfront optical gain. Operating the gamma camera at high frame rates leads to a massiv...
B S McDonald,S Shokouhi,H H Barrett et al. B S McDonald et al.
We investigated a scheme for concurrently detecting low- and high-energy emissions from (123)I with a stacked silicon double-sided strip detector (DSSD) and modular scintillation camera (Modcam) from the FastSPECT II design. We sequentially...
Mitchell D Miller,Ashley M Deacon Mitchell D Miller
Crystallographic end-stations require a significant investment in state-of-the-art equipment, as well as a significant effort in software development. The equipment often sits idle during annual maintenance shutdowns. In order to utilize th...
Vivek V Nagarkar,Bipin Singh,Liang Guo et al. Vivek V Nagarkar et al.
Third generation synchrotron sources such as the Advanced Photon Source at Argonne National Laboratory, Argonne, IL, are outstanding tools for X-ray diffraction and scattering studies of non-crystalline biological materials. However, these ...
Martin D de Jonge,Stefan Vogt,Daniel Legnini et al. Martin D de Jonge et al.
We developed a technique for performing quantitative phase reconstructions from differential phase contrast images obtained using a configured detector in a scanning transmission X-ray microscope geometry. The technique uses geometric optic...
Erik L Ritman Erik L Ritman
For whole-body CT images of small rodents, a voxel resolution of at least 10(-3) mm(3) is needed for scale-equivalence to that currently achieved in clinical CT scanners (∼1 mm(3)) in adult humans. These "mini-CT" images generally require ...
William W Moses William W Moses
Simple theory predicts that the statistical noise variance in PET can be reduced by an order of magnitude by using time-of-flight (TOF) information. This reduction can be obtained by improving the coincidence timing resolution, and so would...