X Michalet,O H W Siegmund,J V Vallerga et al.
X Michalet et al.
We have developed a photon-counting High-temporal and High-spatial resolution, High-throughput 3-Dimensional detector (H33D) for biological imaging of fluorescent samples. The design is based on a 25 mm diameter S20 photocathode followed by...
A small-animal imaging system capable of multipinhole circular/helical SPECT and parallel-hole SPECT [0.03%]
一种能够进行多孔圆/螺旋SPECT和平行孔SPECT的小动物成像系统
Jianguo Qian,Eric L Bradley,Stan Majewski et al.
Jianguo Qian et al.
We have designed and built a small animal single photon emission computed tomography (SPECT) imaging system equipped with parallel-hole and multipinhole collimators and capable of circular or helical SPECT. Copper-beryllium parallel-hole co...
H Kim,C M Kao,Q Xie et al.
H Kim et al.
As an approach to realizing all-digital data acquisition for positron emission tomography (PET), we have previously proposed and studied a multi-threshold sampling method to generate samples of a PET event waveform with respect to a few use...
Recent advances in BazookaSPECT: Real-time data processing and the development of a gamma-ray microscope [0.03%]
BazookaSPECT最近的进展:实时数据处理及伽马射线显微镜的发展
Brian W Miller,Harrison H Barrett,Lars R Furenlid et al.
Brian W Miller et al.
Recent advances have been made with the BazookaSPECT detector, a high-resolution CCD-based gamma camera which utilizes an MCP-based image intensifier for upfront optical gain. Operating the gamma camera at high frame rates leads to a massiv...
B S McDonald,S Shokouhi,H H Barrett et al.
B S McDonald et al.
We investigated a scheme for concurrently detecting low- and high-energy emissions from (123)I with a stacked silicon double-sided strip detector (DSSD) and modular scintillation camera (Modcam) from the FastSPECT II design. We sequentially...
An X-ray microsource based system for crystal screening and beamline development during synchrotron shutdown periods [0.03%]
基于X射线微源的用于晶体筛选及同步辐射光束线发展的关机期间系统
Mitchell D Miller,Ashley M Deacon
Mitchell D Miller
Crystallographic end-stations require a significant investment in state-of-the-art equipment, as well as a significant effort in software development. The equipment often sits idle during annual maintenance shutdowns. In order to utilize th...
Cost-effective EMCCD-based detector for time-resolved biological SAXS applications [0.03%]
一种低成本的EMCCD生物小角散射时间分辨检测器
Vivek V Nagarkar,Bipin Singh,Liang Guo et al.
Vivek V Nagarkar et al.
Third generation synchrotron sources such as the Advanced Photon Source at Argonne National Laboratory, Argonne, IL, are outstanding tools for X-ray diffraction and scattering studies of non-crystalline biological materials. However, these ...
A method for phase reconstruction from measurements obtained using a configured detector with a scanning transmission X-ray microscope [0.03%]
一种利用配置探测器的扫描透射X射线显微镜测量进行相位重建的方法
Martin D de Jonge,Stefan Vogt,Daniel Legnini et al.
Martin D de Jonge et al.
We developed a technique for performing quantitative phase reconstructions from differential phase contrast images obtained using a configured detector in a scanning transmission X-ray microscope geometry. The technique uses geometric optic...
Erik L Ritman
Erik L Ritman
For whole-body CT images of small rodents, a voxel resolution of at least 10(-3) mm(3) is needed for scale-equivalence to that currently achieved in clinical CT scanners (∼1 mm(3)) in adult humans. These "mini-CT" images generally require ...
William W Moses
William W Moses
Simple theory predicts that the statistical noise variance in PET can be reduced by an order of magnitude by using time-of-flight (TOF) information. This reduction can be obtained by improving the coincidence timing resolution, and so would...