We present a quantitative study on the performance of cadmium zinc telluride (CZT), thallium-doped sodium iodide (NaI(Tl)) and germanium (Ge) detectors as potential Compton camera absorbers. The GEANT4 toolkit was used to model the performa...
Certification and licensing of clinical medical physicists in AFOMP countries [0.03%]
AFOMP各国临床医学物理师的认证与执照制度
W H Round
W H Round
In many countries the education and training of medical physicists has changed over the last few decades from being rather ad hoc to becoming structured with residency programs becoming quite common. These are often followed by formal certi...
Hidden stressors in the clonogenic assay used in radiobiology experiments [0.03%]
放射生物学实验中克隆形成试验的隐匿应激因素
M D E Potter,N Suchowerska,S Rizvi et al.
M D E Potter et al.
While clonogenic assays are extensively used in radiobiology, there is no widely accepted procedure for choosing the composition of the cell culture media. Cell line suppliers recommend a specific culture medium for each cell line, however ...
A hybrid radiation detector for simultaneous spatial and temporal dosimetry [0.03%]
一种用于同时进行空间和时间剂量测量的混合辐射探测器
C Poole,J V Trapp,J Kenny et al.
C Poole et al.
In this feasibility study an organic plastic scintillator is calibrated against ionisation chamber measurements and then embedded in a polymer gel dosimeter to obtain a quasi-4D radiation detector. This hybrid dosimeter was irradiated with ...
John Cormack
John Cormack
Identification of motion from multi-channel EMG signals for control of prosthetic hand [0.03%]
基于多通道表面肌电信号的假手运动模式识别研究
P Geethanjali,K K Ray
P Geethanjali
The authors in this paper propose an effective and efficient pattern recognition technique from four channel electromyogram (EMG) signals for control of multifunction prosthetic hand. Time domain features such as mean absolute value, number...
Diagnostic reference levels for mammography in BreastScreen Queensland [0.03%]
乳腺筛查 queensland省的乳腺X线摄影诊断参考水平
David L Thiele,Mike Irvine,David Want et al.
David L Thiele et al.
Diagnostic reference levels assist in the optimisation of radiation exposure parameters within a medical imaging facility. As no Australian DRLs currently exist, radiation doses from mammography in BreastScreen Queensland are analysed. Prog...
A fast numerical method for calculating the 3D proton dose profile in a single-ring wobbling spreading system [0.03%]
单环摆动散射系统中三维质子剂量分布的快速计算方法
Z Riazi,H Afarideh,R Sadighi-Bonabi
Z Riazi
Based on the determination of protons fluence at the phantom's surface, a 3D dose distribution is calculated inside a water phantom using a fast method. The dose contribution of secondary particles, originating from inelastic nuclear intera...
Monte Carlo study of the energy response and depth dose water equivalence of the MOSkin radiation dosimeter at clinical kilovoltage photon energies [0.03%]
一种基于MOS皮肤辐射剂量计的临床千伏光子能量下的能量响应和深度剂量当量水的研究的蒙特卡罗研究
C P L Lian,M A R Othman,D Cutajar et al.
C P L Lian et al.
Skin dose is often the quantity of interest for radiological protection, as the skin is the organ that receives maximum dose during kilovoltage X-ray irradiations. The purpose of this study was to simulate the energy response and the depth ...
GEANT4 simulation of the effects of Doppler energy broadening in Compton imaging [0.03%]
基于GEANT4的多普勒能量展宽对康普顿成像影响的模拟研究
C Z Uche,M J Cree,W H Round
C Z Uche
A Monte Carlo approach was used to study the effects of Doppler energy broadening on Compton camera performance. The GEANT4 simulation toolkit was used to model the radiation transport and interactions with matter in a simulated Compton cam...