International comparison: Report of the Pilot study CCQM-P188 (in parallel with CCQM-K120.a and b) [0.03%]
国际比对: pilot研究CCQM-P188报告(与CCQM-K120.a和b平行)
Edgar Flores,Joële Viallon,Tiphaine Choteau et al.
Edgar Flores et al.
C Stambaugh,H Shakeel,M Litorja et al.
C Stambaugh et al.
Despite ubiquitous implementation of the quartz crystal microbalance (QCM) for measuring thin film thickness throughout industry and academia, a direct link to the SI (International System of Units) does not exist. Confidence in QCM measure...
Linearity Characterization and Uncertainty Quantification of Spectroradiometers via Maximum Likelihood and the Non-parametric Bootstrap [0.03%]
光谱辐射计的线性特征及不确定性量化分析——基于最大似然和非参数Bootstrap法
Adam L Pintar,Zachary H Levine,Howard W Yoon et al.
Adam L Pintar et al.
A technique for characterizing and correcting the linearity of radiometric instruments is known by the names the "flux-addition method" and the "combinatorial technique". In this paper, we develop a rigorous uncertainty quantification metho...
Allan H Harvey
Allan H Harvey
Constant-volume gas thermometry data published in 1989 for the difference between the thermodynamic temperature and the International Practical Temperature Scale of 1968 are corrected in two ways. A refined estimate of the thermal expansivi...
High amplification laser-pressure optic enables ultra-low uncertainty measurements of the optical laser power at kilowatt levels [0.03%]
高增益激光压力光学技术实现千瓦量级光学激光功率的超低不确定度测量
Alexandra B Artusio-Glimpse,Kyle A Rogers,Paul A Williams et al.
Alexandra B Artusio-Glimpse et al.
We present the first measurements of kilowatt laser power with an uncertainty less than 1 %. These represent progress toward the most accurate measurements of laser power above 1 kW at 1070 nm wavelength and establish a more precise link be...
S Eckel,D S Barker,J Fedchak et al.
S Eckel et al.
We demonstrate operation of a constant-pressure flowmeter capable of generating and accurately measuring flows as low as 2 × 10-13 mol/s. Generation of such small flows is accomplished by using a small conductance element with C ≈ 50 nL/s...
Generalized Electrical Substitution Methods and Detectors for Absolute Optical Power Measurements [0.03%]
用于绝对光功率测量的广义电测法及探测器
S I Woods,J E Neira,J E Proctor et al.
S I Woods et al.
We have developed generalized methods for electrical substitution optical measurements, as well as cryogenic detectors which can be used to implement them. The new methods detailed here enable measurement of arbitrary periodic waveforms by ...
Report on the SIM Photometry and Radiometry Key Comparison of Spectral Regular Transmittance (SIM.PR-K6.2010) [0.03%]
国际比对SIM光度和辐射度关键技术比对——透过率(SIM.PR-K6.2010)的国内部分研究报告
Catherine Cooksey,Blaza Toman
Catherine Cooksey
Facility for Calibrating Anemometers as a Function of Air Velocity Vector and Turbulence [0.03%]
用于校准风速计的设施,作为气流速度矢量和湍流的函数
Iosif I Shinder,Michael R Moldover,B James Filla et al.
Iosif I Shinder et al.
NIST calibrates anemometers as a function of airspeed vector and turbulence intensity (Tu). The vector capability (sometimes called "3-D") is particularly important for calibrating multi-hole differential-pressure probes that are often used...
Achievement of 0.005 % combined transfer uncertainties in the NIST detector calibration facility [0.03%]
NIST探测器校准设施达到0.005%的综合传输不确定度成就
J M Houston,C J Zarobila,H W Yoon
J M Houston
Improvements in a lamp-monochromator-based facility at the National Institute of Standards and Technology (NIST), the Visible near-infrared Spectral Comparator Facility (VisSCF) which is used to calibrate optical detectors for spectral radi...